Laserfiche WebLink
; . <br /> HAZA_ S MATERIALS—GENERAL PROVISIONS <br /> t It ithin a single outdoor control area of a Group M occupancy 5003.11.3.6 Container size. Individual containers shall not <br /> px xrvshall not exceed the amounts set forth in Table 5003.11.1. exceed 100 pounds(45 kg)for solids or 10 gallons(38 L)for <br /> . .;.The amounts of storage of nonflammable solid and liquids in storage and display areas. o <br /> r nonflammable or noncombustible liquid hazardous •3 The individual containers may not exceed 10 gallons " <br /> ,material stored and displayed in outside areas may (38 L) for liquids or 100 pounds (45 kg)for solids. <br /> not exceed the MAQs given in Table 5003.11.1. 5003.11.3.7 Incompatible materials. Incompatible materi- <br /> 5003.11.3 Storage and display.Storage and display shall be als shall be separated in accordance with Section 5003.9.8. <br /> in accordance with Sections 5003.11.3.1 through <br /> x5003.11.3.10. +Incompatible materials may not be stored together <br /> n unless separated in accordance with Section <br /> •`•Storage and display of nonflammable solid and non- 5003.9.8. <br /> ' flammable or noncombustible liquid chemicals must 5003.11.3.8 Floors.Floors shall be in accordance with Sec- <br /> comply with Sections 5003.11.3.1 through tion 5004.12. <br /> 5003.11.3.10. <br /> 5003.11.3.1 Density. Storage and display of solids shall not Floors in storage and display areas must meet the <br /> requirements of Section 5004.12. <br /> a- xceed 200 pounds per square foot(976 kg/m2) of floor area <br /> ': Aactually occupied by solid merchandise. Storage and display 5003.11.3.9 Aisles.Aisles 4 feet(1219 mm)in width shall be <br /> ' maintained on three sides of the storage or display area. <br /> o�.liquids shall not exceed 20 gallons per square foot (0.50 g P Y <br /> in)of floor area actually occupied by liquid merchandise. +The storage or display area must be surrounded on <br /> 1=. The key element to this section is the statement"floor at least three sides with an aisle that is at least 4 feet <br /> =area actually occupied by solid or liquid merchan- (1219 mm)wide. <br /> dise." As an example, if 10 square feet (0.9 m2) of 5003.11.3.10 Signs.Hazard identification signs shall be pro- <br /> ;floor area is to be used for storage or display,the limit vided in accordance with Section 5003.5. <br /> 'allowed would be 2,000 pounds (908 kg) (200 pounds •Signs meeting the requirements of NFPA 704 and <br /> x 10 square feet) of solid material or 200 gallons (757 <br /> �� Section 5003.5 must be installed. <br /> L-) (20 gallons x 10 square feet) of liquid material. <br /> -003.11.3.2 Storage and display height. Display height 5003.12 Outdoor control areas. Outdoor control areas for <br /> finished floor in hazardous materials in amounts not exceeding the maximum <br /> all not exceed 6 feet(1829 mm)above the <br /> display areas of Group M occupancies. Storage height shall allowable quantity per outdoor control area shall be in accor- <br /> sot exceed 8 feet(2438 mm)above the finished floor in stor dance with the following: <br /> ge areas of Group M and Group S occupancies. 1. Outdoor control areas shall be kept free from weeds, <br /> debris and common combustible materials not neces- <br /> -•This section limits Group M display height to 6 feet <br /> sary to the storage. The area surrounding an outdoor <br /> (1829 mm). In storage areas of Group M occupancies control area shall be kept clear of such materials for a <br /> and Group S occupancies, the storage- height is <br /> -zl=increased to 8 feet (2438 mm) in recognition of the minimum of 15 feet(4572 mm). <br /> ,fact that these areas are not normally open to the 2. Outdoor control areas shall be located not closer than <br /> public. These areas are also subject to the density 20 feet (6096 mm) from a lot line that can be built <br /> 3 <br /> x requirements of Section 5003.11.3.1. upon,public street,public alley or public way. <br /> 5003.11.3.3 Container location. Individual containers less Exceptions: <br /> " tean 5 gallons (19 L) or less than 25 pounds (11 kg) shall be 1. For solid and liquid hazardous materials, a 2- <br /> ' cored or displayed on pallets,racks or shelves. hour fire-resistance-rated wall without open- <br /> •••When the capacity of individual containers is less ings extending not less than 30 inches (762 <br /> 11 than either 5 gallons (19 L) or 25 pounds (11 kg),they mm)above and to the sides of the storage area <br /> 11,7 ' -"Must be displayed on pallets, racks or shelves. shall be allowed in lieu of such distance. <br /> 1111 5003.11.3.4 Racks and shelves. Racks and shelves used for 2. For compressed gas hazardous materials, <br /> storage or display shall be in accordance with Section unless otherwise specified, the minimum <br /> 0e 9.9. required distances shall not apply when fire <br /> ' barriers without openings or penetrations hav- <br /> vThe design of racks and shelves must meet the <br /> ing a minimum fire-resistance rating of 2 <br /> ,gl , requirements of Section 5003.9.9. <br /> hours interrupt the line of sight between the <br /> i ;003.11.3.5 Container type. Containers shall be approved storage and the exposure.The configuration of <br /> '';' :;, :1r':the intended use and identified as to their content. the fire barrier shall be designed to allow nat- <br /> K� Containers must be approved for the storage or dis- ural ventilation to prevent the accumulation of <br /> n?(.-( ;.�'4e playconditions. hazardous <br /> gas concentrations. <br /> . I11 c <br /> r �, i tx(t12INTERNATIONAL FIRE CODE®COMMENTARY 50-39 <br /> : n <br />