Laserfiche WebLink
tr"b‘ SNOHOMISH <br /> is HEALTH DISTRICT <br /> WWW.SNOHD.ORG Environmental Health Division <br /> March 23, 2017 ' <br /> 5 8"? "a �b� . '':.eel I -- <br /> C�� ) D <br /> Gayathri Srinivasan - <br /> 18520 35th Dr SE ma 28 2017 <br /> Bothell, WA 98012 <br /> CITY <br /> Subject: Proposed Bothell Foods LLC, 4 Olympic Blvd., Everett pe �� EVERETT Permit <br /> C <br /> Dear Srinivasan: <br /> Your plans have been reviewed with the Rules and Regulations of the State Board of HealthSe�, and with <br /> the policies of the Snohomish Health District. With the addition of the following conditions, the plans <br /> are approved. <br /> 1. The conditional approval of the plans for Bothell Foods LLC was based upon the plans, <br /> menu and HACCP submitted February 14, 2017. Any changes to these items will void this <br /> approval. <br /> 2. The Health District operating permit application process must be completed prior to opening for <br /> business. This facility will be classified as a high risk food establishment with 0-12 seats. <br /> 3. Three-compartment sinks must be NSF or equivalent listed with rounded corners and integral <br /> drainboards at both ends. The basins of the three-compartment sink must be large enough to fit the <br /> largest item needing to be washed. <br /> 4. An indirect waste drain (an air gap) is required for the food preparation sinks, mechanical dishwasher, <br /> ice machine, walk-in refrigeration, and any equipment in which food is placed. Please note that a <br /> direct drain to a grease trap is not considered an indirect drain even if the grease trap is indirectly <br /> drained. <br /> 5. Each food preparation sink must be NSF or equivalent listed with at least one integral drainboard. <br /> 6. A horizontal separation of at least 16 inches or a pony wall, from the floor to at least 16 inches <br /> above the sink basin, is required between the raw meat/poultry/seafood preparation sink and ready <br /> to eat food preparation and storage areas. The only acceptable option to the pony wall, other than <br /> the 16 inch horizontal separation, is the use of a partition of at least 11/4 inch in thickness (similar to <br /> the partitions in restroom stalls)from the floor to at least 16 inches above the sink basin of a <br /> material that is waterproof. <br /> 7. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required <br /> between the handwash sink and all food preparation areas. <br /> 8. Water heaters must be of sufficient size to provide hot water to dishwasher and/or scullery sinks <br /> and at the same time provide hot water to all handwash sinks. <br /> 9. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility <br /> must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational <br /> inspection. This is required so that proper testing of the 15-second time requirement for hot water <br /> availability can be completed. <br /> 10.All food service equipment, botb_nev.►t_aacLus-edrmust_be_listed_by_the_Nationa/-Sanitation - <br /> Foundation or equivalent for its intended use. Used and new refrigeration must be capable of <br /> holding food at temperature of 41°F or below. <br /> 11. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed <br /> food service establishment. Used equipment must be clean, in proper operating condition, and in <br /> good repair. Used refrigeration must be capable of holding at a temperature of 41°F or below. <br /> 3020 Rucker Avenue, Suite 104 ■ Everett, WA 98201-3900 ■ tel: 425.339.5250 ■ fax: 425.339.5254 <br />