|
�
<br /> � �
<br /> •N o
<br /> � U
<br /> . . . . . . . � � _
<br /> �
<br /> �
<br /> � _�
<br /> t0
<br /> �
<br /> . . . . � . � . . � � . � � � � . � . O �
<br /> �
<br /> .. . . . . � . . . . . . �
<br /> E Q U I P M E N T S Z
<br /> � .
<br /> . � � . . . . . o o � o 0 4 0 0 � � a .♦
<br /> � 2� O v
<br /> �2148� 2148--' �2148� �c146 � � rn �
<br /> �
<br /> � � �
<br /> — �
<br /> � � Q— � `r �
<br /> U � U.� U ( 21 � �,
<br /> (n � N � Q i-�+ -�.�., -�� '_'N
<br /> Item Equipment � � � o � � .°'. �' w �� �v � o Elec �� � � X
<br /> 9
<br /> No Qty Equipment Category Remarks Q � _ > o._. c.� o � z wQ w¢ w� Remarks 22 �T� . � "
<br /> 1 1 WALK-IN COOLER 25 1 1 1 " 23 h+�i
<br /> 2 20 Dolly, Pizza Dough Box •
<br /> 3 1 Shelving, Wire � �
<br /> 4 1 Sheiving, Wire � �� 24 / h� Q
<br /> 5 1 Shelving, Wire v m
<br /> 25 -' A/ �
<br /> I'i'� _,
<br /> 6 ,) � J rn
<br /> � �
<br /> 7 1 � � � a
<br /> 8 2 Mixer, Floor � �
<br /> 16.4 1 1 16.4 � ¢ a
<br /> 9 12 Rack, Dunna ge - � ;�-------{r '- o
<br /> i4 i4 N U
<br /> 10 1 Shelving, Wire _O O ;I; ;I; � �
<br /> 11 1 Shelving, Wire � � � ;;; ;;
<br /> 12 1 Shelving, Wire � �;� �;� 27 OQ
<br /> 13 6 Bin, Ingredient � � J 8 15 II� II�
<br /> � �
<br /> 14 1 Table, Baker s w/Splash ��� ��
<br /> I �
<br /> 15 1 Table, Work ' � � . �} ------,+a 2$
<br /> � � _;___, � o Q
<br /> 16 1 DOUGH ROUNDER � � � � '�
<br /> 63 08 230 � �/
<br /> 17 1 Dolly, Pizza Dough Box � - ; --; ��� L.L
<br /> � -- r---� i
<br /> 18 1 � �4 � --+---��{I
<br /> �
<br /> 19 1 � 1
<br /> � �__—��n
<br /> [� 0 , �.�__� , N
<br /> 20 1 Sink, Mop � --�---_�� N
<br /> 21 1 Service Sink Faucet, Wall Mount � � � �1� � _; ^�'
<br /> �
<br /> � ^
<br /> 22 1 Sink, NSF, 1 comp, 18 gauge
<br /> N � i ==�==-i� I..L
<br /> q, � i i n
<br /> 23 1 Faucet> Wall Mount � � � � 1 � _�`---�� ' � Q
<br /> 24 1 Hand Sink, W
<br /> all Mount u u �+� �
<br /> 9 10 '
<br /> 25 1 Faucet, Wall Mount � � � 1 � �2 O (n � '
<br /> 27 1 Sink, NSF, 3 comp, 16 gauge ����
<br /> 5 � � � W
<br /> 28 1 Pre-Rinse Faucet, Wall Mount � � � II � o � � � � o 0 0 � � � � M ,��' �/
<br /> �I�� 148 2148 _ 2148 2148^ �2148 2148� �■�J C W
<br /> U 0 O O O O G
<br /> L Q �
<br /> � U W
<br /> �
<br /> � i
<br /> i
<br /> O �
<br /> i
<br /> ELECTRICAL ROUGH-IN P�AN O
<br /> Scale: 1/4"=1'-0" �
<br /> W
<br /> REVISION INFORMATIpN
<br /> # START PERMIT
<br /> VERIFY ALL REQUIREMENTS o MM'°°m
<br /> NOT PROVIDED BY KEC. # REVISION _-DELTA
<br /> � osrza���
<br /> 2 --
<br /> 3 ---
<br /> 4 ---
<br /> 5 ---
<br /> 6 ---
<br /> 7 ---- ----
<br /> 8 --- ---
<br /> This plan is the property of Bargreen
<br /> Ellingson and is loaned subject to the
<br /> condition that it is not ko be copied,
<br /> reproduced,or distributed either in
<br /> whole or in part,without written
<br /> E L E C T R I C A� �E G E f� D E�E C T R I C A� N 0 T E S pe�,�ss�an,and is not to be used in
<br /> � any way detrimental to the best
<br /> �
<br /> interests of the company,
<br /> '�_____=_,' � 1. ALL ELECTRICAL ROUGH-W WORK AND FINAL CONNECTIONS TO ALL FOOD SERVICE AND RELATED EQUIPMENT AS SHOWN ON THE 9. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL ELECTRICAL COMPONENTS FOR WALK-IN REFRIGERATORS AND �Zo,s BAR�REEN E��w�SON w�.
<br /> �� ;� ; ;---------; SYMBOL DESCRIPTION DOOR VENTS SOLENOIDS TIME CLOCKS DEFROST CIRCUITS DOOR HEATER AND
<br /> „ ;; ; ; ; O �uNCr�oN Box KITCHEN EQUIPMENT CONTRACTOR'S PLANS TO BE PERFORMED BY THE ELECTRICAL CONTRACTOR PER NATIONAL AND LOCAL CODES. FREEZERS INCLUDING, BUT NOT LIMITED T0: LIGHTS, , , , , ,
<br /> �, „ „ , �_________, INTERCONNECTIONS BETWEEN REMOTE COMPRESSORS AND �NTERIOR MOUNTED EVAPORATOR COILS. ELECTRICAL SHALL ALSO PROVIDE � DRAWN BY:
<br /> o L�------J J � � 120 VOLT OUTLET (DCO) 2. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL STAINLESS STEEL OUTLET AND RECEPTACLE COVERS IN SERVICE AREAS.� DISCONNECTS AND THERMO-OVERLOAD PROTECTION FOR COMPRESSORS. �
<br /> o � � w B.FLANNERY
<br /> w � � 208 VO�T OUTLET (SCO PROJECT MANAGER:
<br /> � ) 3. THE ELECTRICAL CONNECTIONS, SPECIFICATIONS AND DIMENSIONS SHOWN ON THESE PLANS ARE FOR FOOD SERVICE EQUIPMENT ONLY. 10. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL HEAT TAPE ON DRAIN LINES IN DANGER OF FREEZING. VERIFY LENGTH �
<br /> w 36 37 O E�c��cA� STUB , WITH REFRIGERATION CONTRACTOR. � S.BAUTISTA
<br /> Z SEE THE ARCHITECT S PLAN SET FOR ADDITIONAt ELECTRICAL REQUIREMENTS INCLUDING OFFICE, MENU BOARDS, TELEPHONE AND DATA
<br /> � o FLOOR OUTLET LINES, ETC.
<br /> = EXH AU ST FAN S 8c M AK E U P AI R U N f T � DEDICA�E� / �So�,4TEo 11. THE ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTS AT THE POWER BOX FOR EACH IGE MACHINE HEAD. � SHEET TITLE:
<br /> _ �
<br /> � VERIFY LOCATION $ sw�TCH 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS FOR EQUIPMENT HOOK-UPS AS REQUIRED BY CODE AND
<br /> � 12. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE INTERCONNECT SWITCHING BETWEEN THE KITCHEN w ELECTRICAL
<br /> ¢ LABELING. �
<br /> a � ucHT �►xTURE HOOD EXHAUST FANS AND THE KITCHEN MAKE-UP AIR SYSTEMS AS REQUIRED PER LOCAL CODE AND AUTHORITIES. ROUGH-IN
<br /> � /� FlELD CONNECTION
<br /> � 5. ALL ELECTRICAL ROUGH-IN WORK AND ALL FINAL CONNECTIONS FOR ALL ITEMS SHOWN AND SPECIFIED ON THESE PLANS BY �3. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL CONTACTORS ON ALL ELECTRICAL � PLAN
<br /> w �w HEAT TAPE BARGREEN ELLINGSON SHALL BE PERFORMED BY THE ELECTRICAL CONTRACTOR.
<br /> = OUTLETS, JUNCTION BOXES, ETC. LOCATED UNDER ANY CLASS I EXHAUST HOOD SO AS TO DISCONNECT UPON ACTIVATION OF THE FIRE V�
<br /> m 4 MoroR SUPPRESSION SYSTEM. SHEET NUMBER
<br /> J 6. UNLESS OTHERWISE SPEGFIED IN THESE PLANS OR QTHER WRITTEN CONTRACTS, IT SHALL BE THE RESPONSISILITY OF THE �
<br /> o O r�ERMosTAT ELECTRtCAL CONTRACTOR TO PROVIDE ALL ELECTRICAL-TYPE MATERIALS INCLUDING, BUT NOT LIMITED T0: WIRING, SWITCHES, W
<br /> �
<br /> � O so�ENol� DISCONNECTS, FLEX, CONDUIT, CONTACTORS, TRANSFORMERS, THERMAL OVERLOAD PROTECTORS, MAGNETIC STARTERS, SHUNT TRIP 14. ELECTRICAL CONTRACTOR SHALL VERIFY REQUIREMENTS OF CASH REGISTERS, PRINTERS, COMPUTERS, SOUND SYSTEM, ETC. [�
<br /> o J
<br /> Y � P.o,s, NETWORK CONNECTION BREAKERS, ELECTRICAL PANELS, CORDS, PLUGS, COVERS, ETC. INCLUDING CONDUIT RUNS AND DEDICATED / ISOLATED OUTLET REQUIREMENTS.
<br /> O
<br /> � 41 Co 120V/1�/15 AMP CONVENIENCE OUTLET r—
<br /> � 7. ELECTRICAL CONTRACTOR SHALL PROVIDE THE KITCHEN EQUIPMENT CONTRACTOR WITH ELECTRICAL PANEL(S) SIZE AND LOCATION 15. ALL DIMENSIONS SHOWN ARE FROM GRID LINES, FINISHED WALLS OR FINISHED FLOORS TO CENTER LINE OF ELECTRICAL OUTLET �
<br /> m 0 VERIFY CONN. TYPE & POWER REQ. BOXES. HEIGHTS ARE NOT TO BE TAKEN FROM CURBS OR PLATFORMS.
<br /> N ALONG WITH AVAILABLE VOLTAGE AND PHASE.
<br /> N REMOTE CONDENSING UNITS a PHONE N 3 OF 16
<br /> �
<br /> VERIFY LOCATION s. ANY LOW VOLTAGE WIRING FOR REMOTE WALK-IN CONTROL PANEL TO BE INSTALLED BY ELECTRICIAN. 16. TEMPERATURE SENSORS RELATED TO THE HOOD SYSTEM, AND INTENDEQ TO BE INSTALLED IN THE KITCHEN SPACE, \ PROJECTNUMBER
<br /> � SHALL BE INSTALLED BY THE ELECTRICAL CONTRACTOR ACCORDING TO TNE MANUFACTURER'S SPECIFICATIONS. 00
<br /> O 4307
<br />
|