1802 75TH ST SW 2017 Plans 2022-11-07
>
Address Records
>
75TH ST SW
>
1802
>
Plans
>
1802 75TH ST SW 2017 Plans 2022-11-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2022 9:50:18 AM
Creation date
5/2/2019 11:23:54 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SW
Street Number
1802
Permit
B1703-028
M1703-082
Year
2017
Notes
SNO CO PUD - TI TO SUBDIVIDE OFFICE SPACE INTO 2 OFFICES NEW ROOFTOP UNIT
Address Document Type
Plans
Imported From Microfiche
No
该页面上没有批注。
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � _ _ - -- <br /> H n R G I 5 <br /> � � mechanical <br /> . � electrical <br /> GENERAL GROUNDING ONE LINE DIAGRAM DRAWING INDEX telecommunications <br /> security <br /> energy <br /> � 1201 third avenue,suite 600 �. <br /> .��- EXISTING ELECTRICAL TO BE REMOVED —�— GROUNDING CONDUCTOR ---- EQUIPMENT ENCLOSURE E0.1 LEGEND AND DRAWING INDEX te206.41833176 w har8s.biz , <br /> EXISTING ELECTRICAL TO REMAIN Q GROUND ROD _� g�g E0.2 ABBREVIATIONS AND GENERAL NOTES <br /> '1' E0.3 ELECTRICAL SPECIFICATIONS `� <br /> NEW ELECTRICAL WORK �—� GROUNDING BUSBAR WIRE ED1.1 ELECTRICAL DEMO FLOOR PI�AN � � <br /> - - � - MATCHLWE QR PROPERTY LINE EQUIPMENT GROUNDING CONNECTION --o— TERMINAL/LUG E1.1 ELECTRICAL FLOOR PLAN � � a <br /> � <br /> - E8.1 ELECTRICAL DETAILS <br /> � � � � -�- <br /> CONNECTION <br /> R ED PLAN BOUNDARY <br /> ENLA G <br /> , _ � <br /> � GROUNDING STRAP ED9.1 DEMOLITION ONE-LINE DIAGRAM �►L �` <br /> � Q DELTA E9.1 PARTIAL ONE-LINE DIAGRAM <br /> E1.1 DETAIL/PLAN IDENTIFIER RECEPTACLES ��2(I� <br /> � <br /> WYE <br /> E10.1 PANEL SCHEDULES <br /> A �F, Th e <br /> DEVICE SUB <br /> SCRIPTS <br /> E1,1 SECTiON IDENTIFIER �� GFI,wP,IG OR OTHER SUBSCRIPT) �� POWER TRANSFORMER <br /> +42" 12 � <br /> ��(CIRCUIT NUMBER) D r i f t m i e r <br /> � NON-STANDARD MOUNTING HEIGHT C U R R E N T T R A N S F O R M E R <br /> A <br /> � ) � <br /> LEVATION ID NTIFIER <br /> . <br /> E1.1 �7 <br /> E E <br /> -� SPECIAL RECEPTACLE � - -p� A rc h 1 t e c s � 1 •�• <br /> REVISI ON D E F I N I T I O N A R E A, A R E A E N C I R C L E D i � � T R A N S F E R S W I T C H <br /> CONTAINS CHANGES MADE SUBSEQUENT TO � DUPLEX RECEPTACLE � � � �J <br /> '�983 Lear �Va NE <br /> PREVIOUS ISSUE J <br /> � _ _ � <br /> y <br /> � FOURPLEX RECEPTACLE o-v-0 CIRCUIT BREAKER, F�XEo R e dm o n d �VA 9 8 0 5 2 <br /> � <br /> 1 <br /> REVISION CALLOUT � <br /> � <br /> � DUPLEX RECEPTACLE, ABOVE COUNTER .{���}., CIRCUIT BREAKER, DRAWOUT �. �j �j <br /> MOUNTED 4"TO CENTERLINE ABOVE BACKSPLASH ( ��� l 8 81 �V 0 V <br /> � <br /> ) <br /> \ / <br /> � FLAG NOTE TAG FOURPLEX RECEPTACLE, ABOVE COUNTER � <br /> DISCONNECT SWITCH <br /> ' e .co <br /> � mailC�dr iftml r m <br /> (MOUNTED 4"TO CENTERLINE ABOVE BACKSPLASH.) <br /> O DEMOLITION NOTE TAG — <br /> � SPLIT WIRED DUPLEX RECEPTACLE -�- FUSED SWITCH <br /> � EQUIPMENT TAG <br /> 0 <br /> � DROP CORD RECEPTACLE � FUSE <br /> 0`"�' <br /> aHu-o� MECHANICAL EQUIPMENT TAG � <br /> ti FUSED CUTOUTS M <br /> 1 <br /> � W � <br /> AHU MECHANICAL EQUIPMENT TAG RACEWAYS AND BOXES Q CIRCUIT BREAKER WITH GROUND FAULT V N <br /> GF � •., <br /> DO <br /> �� <br /> ¢ PROTECTION � <br /> � <br /> Y � � <br /> N NORTH ARROW Q JUNCTION BOX ST - d� CIRCUIT BREAKER WITH SHUNT TRIP OPERATOR � Q <br /> � <br /> i <br /> � <br /> � FURNITURE WALL FEED OUTLET BOX �"' <br /> O GF <br /> F - ••• •• <br /> 9OLOCATION WHERE PICTURE WAS TAKEN AND � FUSED SWITCH WITH GROUND FAULT PROTECTION �" I`� <br /> DIRECTION PB PULL BOX � � <br /> �WHERE INDICATED,SUBCRIPT INDICATES PULL BOX NUMBER) O <br /> � Q Q � � � <br /> aMANHOLE K K - �CIRCUIT BREAKERS WITH KEYED INTERLOCK � � C� � <br /> �WHERE INDICATED,SUBCRIPT INDICATES MANHOLE NUMBER) � b� b � � <br /> � �------' 1 v� � <br /> UGHTING HH HANDHOLE � <br /> A MOTOR CONNECTION �j C� <br /> FLOORBOX (SUBSCRIPT INDICATES TYPE,WHERE NO SUBSCRIPT, � Q � �'S" • <br /> ��DEVtCE SUBSCRIPTS �A SEE SPECIFICATIONS) � � �„_ ♦^ <br /> 12ab (LIGHT FIXTURE TYPE) � GENERATOR r•�- v� <br /> ��(CIRCUIT NUMBER/SWITCHLEG) POKETHRU (SUBSCRIPT INDICATES TYPE,WHERE NO SUBSCRIPT, _ � <br /> • � <br /> O SEE SPECIFICATIONS) � <br /> A <br /> � <br /> O METER � � W <br /> T W <br /> POWER POLE FLOOR O CEILING <br /> O , <br /> � <br /> m <br /> WATT HOUR <br /> METER � � <br /> � <br /> �� LIGHTING FIXTURES � � � Z �. <br /> (REFER TO LIGHTWG FIXTURE SCHEDULE SURFACE METAL RACEWAY <br /> FORADDITIONALINFORMATION) AO AMMETER O � <br /> RACEWAY CONCEALED IN WALL OR W CEILING � � <br /> � � (EXPOSED IN UNFINISHED AREAS) � � <br /> OV VOLTMETER O Q � <br /> F--O--� STRIP LfGHTING FIXTURE --- RACEWAY RUN BE�OW FLOOR OR BELOW GRADE � � <br /> ST SHUNT TRIP W <br /> WALL-MOUNTED UGHTING FIXTURE �-�.. O � 0• N <br /> O� � FLEXIBLE RACEWAY C <br /> GF GROUND FAULT PROTECTION <br /> � <br /> GO <br /> RACEWAY CIRCLE DENOTES VERTICAL <br /> O � <br /> � —0 <br /> � � <br /> TRANSITION <br /> � EPM ELECTRONIC POWER METER <br /> � —� RACEWAY CONTINUATION <br /> EMERGENCY LIGHTING FIXTURES SPD SURGE PROTECTIVE DEVICE <br /> �� (REFER TO LIGHTING FIXTURE SCHEDULE ] RACEWAY STUB WITH BUSHING <br /> FOR ADDITIONAL INFORMATION) �— GROUND <br /> � � [—] RACEWAY SLEEVE WITH BUSHINGS LE G E N D AN D <br /> 12,241 AVAILABLE FAULT CURRENT(SYMMETRICAL) TAG <br /> �� � EZ-PATH FIRE STOPPING SLEEVE . <br /> CABLE TRAY 12"W x 4"H OVERHEAD UNLESS 225 FEEDER TAG D RAW I N G I N D E X <br /> � POLE MOUNTED LIGHTING FIXTURE, QUANTITY OF OTHERWISE NOTED <br /> HEADS AS INDICATED. <br /> �o� DOUBLE HEAD, POLE MOUNTED, LIGHTING FIXTURE � CABLE TRAY, OVERHEAD LADDER TYPE <br /> �� LIGHTtNG TRACK WITH FIXTURES <br /> HOMERUN TO PANEL � PRIMARY SWITCH <br /> HA-3 �INDICATES PANEL DESIGNATION AND CIRCUIT NUMBER) <br /> � SELF-CONTAINED BATTERY POWERED EMERGENCY <br /> LIGHTING FIXTURE #�j� �'-(GAUGE OF WIRE OTHER THAN AWG#12) <br /> ���NUMBER OF CONDUCTORS <br /> �(GROUND CONDUCTOR) <br /> � EXIT SIGN, UNIVERSAL MOUNTING �PHASE coN�ucTORs> PAD MOUNT TRANSFORMER <br /> (SHADED AREA INDICATES DIRECTION ARROWS) (NEUTRAL CONDUCTOR) <br /> POWER �°.��� <br /> EXIT SIGN, WALL MOUNTED � -/��JV� ' <br /> � SHADED AREA INDICATES DIRECTION ARROWS) <br /> � <br /> X TRANSFORMER <br /> SWITCHBOARD/SWITCHGEAR <br /> OOCCUPANCY SENSOR, CEILING MOUNTED f � 208Y i <br /> X WHERE INDICATED, SUBSCRIPT INDICATES TYPE �Y�; PANELBOARD, FLUSH MOUNTED I_�_ _120� <br /> �M OCCUPANCY SENSOR, WALL MOUNTED <br /> --�-- PANELBOARD, SURFACE MOUNTED <br /> Q PHOTOSENSOR �FRONT� � PANELBOARD - MAIN LUGS ONLY <br /> SWITCHES B�TRANSFORMER � � <br /> i i <br /> � MOTOR CONNECTION. L� <br /> � SWITCH, SPST UON OR AS DEFINED BY SUBSCRIPT PANELBOARD - MAW CIRCUIT BREAKER <br /> a=SWITCH LEG T=TIMER �+ DISCONNECT SWITCH, NON FUSED � ISSUE DATE: 1 Z O2 1 6 <br /> 3=THREE WAY MC=MOMENTARY CONTACT � � <br /> DRAWN BY: CT <br /> 4=FOUR WAY P=PILOT LIGHT � DISCONNECT SWITCH, FUSED � � <br /> K=KEYED LV=LOWVOLTAGE � CHECKED eY: MJ <br /> D=DIMMER OS=OCCUPANCY SENSOR <br /> LVM=LOW VOLTAGE PROGRAMMABLE VFD VARIABLE FREQUENCY DRNE <br /> PROJECT NUMBER <br /> (a,b,c) OR (a-c) CAN BE USED TO DESIGNATE $ MANUAL MOTOR STARTER WITH THERMAL TELECOMMUNICATIONS <br /> MULTIPLE SWITCHES. M OVERLOADS <br /> 21606 � <br /> ANY COMBINATION OF SWITCH TYPES CAN BE USED. � EQUIPMENT CONNECTION. CONFIRM CONNECTION a FLUSH MOUNT DATA- DEVICE ROUGH-W <br /> (i.e. 3K= 3 WAY KEYED SWITCH) WITH EQUIPMENT MANUFACTURER <br /> OT ALL SYMBOLS MAY APPEAR ON THE DRAWING <br /> SHEET NUMBER <br /> QFis FIRE/SMOKE DAMPER <br /> � PUSHBUTTON CONTROLLER EO. � <br /> � SINGLE OR MULTIPLE BUTTONS) <br />
The URL can be used to link to this page
Your browser does not support the video tag.