My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1802 75TH ST SW 2017 Plans 2022-11-07
>
Address Records
>
75TH ST SW
>
1802
>
Plans
>
1802 75TH ST SW 2017 Plans 2022-11-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2022 9:50:18 AM
Creation date
5/2/2019 11:23:54 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SW
Street Number
1802
Permit
B1703-028
M1703-082
Year
2017
Notes
SNO CO PUD - TI TO SUBDIVIDE OFFICE SPACE INTO 2 OFFICES NEW ROOFTOP UNIT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
H n R G i S <br /> mechanical <br /> electrical <br /> ABBREVIATIONS GENERAL NOTES NON-STRUCTURAL ELECTRICAL COMPONENT NOTES telecommunications <br /> security <br /> . . . . energy � <br /> � . � !-� AM PERE � . 1201 third avenue,suite 600 <br /> 1. PERFORM WORK IN ACCORDANCE WITH APPLICABLE NATIONAL AND 1. THE FOLLOWING ITEMS ARE TAKEN DIRECTLY FROM THE 2015 Seatt�e,wasfiington98101 <br /> AC AIR CONDITIONING; ALTERNATING CURRENT MC MAIN CROSS CONNECT; METAL CLAD (CABLE) STATE CODES AS AMENDED LOCALLY AND ENFORCED BY THE AHJ. INTERNATIONAL BUILDING CODE AND FROM THE AMERICAN SOCIETY t 206.448.3376 w hargis.biz <br /> AF AMP FRAME MCC MOTOR CONTROL CENTER OF CIVIL ENGINEERS (ASCE) STANDARD 7-10. THE CONTRACTOR <br /> AF AMP FUSE; AMP FRAME MCB MAIN CIRCUIT BREAKER 2. OBTAIN AND PAY FOR PERMITS REQUIRED FOR WSTALLATION OF SHALL REFER TO THE ABOVE FOR ADDITIONAL INFORMATION, � • .T+'' <br /> AFF AB OVE FINISHED FL O O R MDF M A I N D I S T R I B U T I O N F R A M E WORK. ARRANGE AND SCHEDULE REQUIRED INSPECTIONS. EXCEPTIONS, AND FURTHER DESCRIPTIONS. THE CONTRACTOR �, <br /> AG ABOVE GRADE MDP MAIN DISTRIBUTION PANEL SHALL ADHERE TO REQUIREMENTS AND AS SUCH, SHALL BE � <br /> 3. DRAWINGS ARE DIAGRAMMATIC IN NATURE. PROVIDE COMPONENTS INCLUDED WITHIN BID. ALSO REFER TO SPECIFICATIONS. <br /> AHJ AUTHORITtES HAVING JURISDICTION MFR MANUFACTURER AS REQUIRED FOR A COMPLETE OPERATIONAL SYSTEM WHETHER OR A "� C� <br /> AHU AIR HANDLING UNIT MH MANHOLE NOT SPECIFICALLY SHOWN ON THE DRAWINGS. 2. 2015 IBC, 1613.1, SCOPE: ARCHITECTURAL, MECHANICAL, ELECTRICAL, <br /> AIC AMPERE INTERRUPTING CURRENT MIN MINIMUM AND NON-STRUCTURAL COMPONENTS THAT ARE PERMANENTLY � <br /> AL ALUMINUM MLO MAIN LUGS ONLY 4. DEVICE LOCATIONS ARE APPROXIMATE> COORDINATE DEVICE ATTACHED TO STRUCTURES AND THEIR SUPPORTS AND � ,�, <br /> ANSI RMERICAN NATIONAL STANDARDS INSTITUTE MM MULTIMODE LOCATIONS AND ELEVATIONS WITH APPROPRIATE DOCUMENTS ATTACHMENTS SHALL BE DESIGNED AND CONSTRUCTED TO RESIST <br /> AS AMP SWITCH MPOE MAIN POINT OF ENTRY INCLUDING CASEWORK SHOP DRAWINGS AND ARCHITECT'S INTERIOR THE EFFECTS OF EARTHQUAKE MOTIONS IN ACCORDANCE WITH I Z I� <br /> ELEVATIONS PRIOR TO ROUGH-IN. ASCE 7-10, EXCLUDING CHAPTER 14 AND APPENDIX 11A. � ' <br /> AT AMP TRIP MPOP MAIN POINT OF PRESENCE <br /> ATS AUTOMATIC TRANSFER SWITCH MTD MOUNTED 5. COORDINATE ELECTRICAL WORK WITH THAT OF OTHER TRADES. 3. 2015 IBC, 1706.1, CONTRACTOR RESPONSIBILITY: THE CONTRACTOR T� e <br /> ATM ASYNCHRONOUS TRANSFER MODE MTS MANUAL TRANSFER SWITCH REFER TO MECHANICAL, ARCHiTECTURAL, STRUCTURAL, DRAWINGS SHALL BE RESPONSIBLE FOR THE CONSTRUCTION OF A <br /> AV AUDIO VISUAL AND SPECIFICATIONS. COORDINATION SHALL OCCUR PRIOR TO SEISMIC-FORCE-RESISTING SYSTEM, DESIGNATED SEISMIC SYSTEM, D ri f tm i e r <br /> AWG AMERICAN WIRE GAUGE N NEUTRAL FABRICATION, PURCHASE, AND INSTALLATION OF WORK. OR SEISMIC-RESISTING COMPONENT LISTED IN THE STATEMENT OF <br /> �N� N�W SPECIAL INSPECTIONS AND SHALL SUBMIT A WRITTEN STATEMENT OF <br /> 6. COORDINATE LOCATION OF LIGHT FIXTURES AND CEILING MOUNTED RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR A rc h i t e c t s P•S• <br /> BAS BUILDING AUTOMATION SYSTEM NAC NOTiFICATION APPLIANCE CIRCUIT DEVICES WITH ARCHITECTURAL REFLECTED CEILING PLANS AND TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. <br /> B A T T B A T T E R I E S N E C N A T I O N A L E L E C T R I C A L C O D E E L E V A T I O N S. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALL INCLUDE � <br /> BKBD BACKBOARD NEMA NATIONAL ELECTRICAL MANUFACTURERS THE FOLLOWING: ( e�S� Le a r � 11 Cl� NE <br /> BIL BASIC IMPULSE INSULATION LEVEL ASSOCIATiON 7. PROVIDE RATED ENCLOSURES AROUND ALL LIGHT FIXTURES <br /> BKR BREAKER NF NON FUSED PENETRATING RATED CEILINGS. COORDINATE WITH ARCHITECTURAL. A. ACKNOWLEDGMENT OF AWARENESS OF THE SPECIAL Redmond, �VA 98052 <br /> BLDG BUILDING NIC NOT IN CONTRACT REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL <br /> NL NIGHT LIGHT 8. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR INSPECTIONS; L�2 5 U S 1 — 1 �O� <br /> LOCATIONS OF EXPANSION/SEISMIC JOINTS. PROVIDE RACEWAY B. ACKNOWLEDGMENT THAT CONTROL WILL BE EXERCISED TO � � <br /> C CONDUIT; DEGREES CELSIUS EXPANSION/SEISMIC JOINTS FOR RACEWAYS CROSSING BUILDING OBTAIN CONFORMANCE WITH THE CONSTRUCTION <br /> CAB CABINET OS OCCUPANCY SENSOR EXPANSION/SEISMIC JOINTS. DOCUMENTS APPROVED BY THE BUILDING OFFICIAL; mailC dr iftmier .COITl <br /> CAT CATEG�RY OFC OPTICAL FIBER CABLE C. PROCEDURES FOR EXERCISING CONTROL WITHIN THE <br /> CATV COMMUNITY ANTENNA TELEVISION OHL OVERHEAD LINE 9. DEMOLISH EXISTING SYSTEMS AS INDICATED ON PLANS OR AS CONTRACTOR'S ORGANIZATION, THE METHOD AND <br /> CB CIRCUIT BREAKER OL OVERLOAD REQUIRED FOR INSTALLATION OF NEW WORK. MATERIAL SHALL BE FREQUENCY OF REPORTING AND THE DISTRIBUTION OF THE <br /> OSP OUTSIDE PLANT REMOVED FROM SITE AND LEGALLY DISPOSED OF OFF SITE IN REPORTS; <br /> ACCORDANCE WITH DIVISION 01 SECTION 017419 CONSTRUCTION D. IDENTIFICATION AND QUALIFICATIONS OF THE PERSON(S) <br /> CCTV CLOSED CIRCUIT TELEVISION WASTE MANAGEMENT AND DISPOSAL UNLESS OTHERWISE DIRECTED. EXERCISING SUCH CONTROL AND THEIR POSITION(S) IN THE <br /> CLG CE{LING P POLE RETURN ITEMS TO OWNER IN EXISTING CONDITION WHEN DIRECTED ORGANIZATION. � � Q <br /> CO CONDUIT ONLY PBX PRIVATE BRANCH EXCHANGE BY OWNER. � N <br /> CT CURRENT TRANSFORMER PF POWER FACTOR 4. DIVISION 26 RESPONSIBILITIES: � � <br /> CU COPPER PH PHASE 10. COMPLETION OF WORK SHALL BE EXECUTED IN ACCORDANCE WITH � � <br /> PIR PASSlVE WFRARED THE PROJECT SCHEDULE. SCHEDULE INSTALLATION WITH OTHER A. HANGERS AND SEISMIC BRACING FOR ELECTRICAL SYSTEMS � L1r <br /> DDC DIRECT DIGITAL CONTROL PIV POST INDICATING VALVE TRADES TO ENSURE PROJECT MILESTONES ARE MET. SHALL BE DESIGNED AND SPECIFIED BY DIVISION 26. DIVISION Q Q <br /> 26 SHALL REFER TO THE ELECTRICAL DRAWINGS FOR � <br /> DEMARC DEMARCATION POINT PNI, PANEL 11. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND DO NOT LOCATIONS OF EQUIPMENT AND ELECTRICAL SYSTEMS AS � � ,, <br /> DISC DISCONNECT PP PATCH PANEL NECESSARILY SHOW EVERY RACEWAY, BOX, CONDUCTOR OR STRUCTURAL DRAWINGS DO NOT SHOW THE LOCATIONS OF �` � <br /> DIST DISTRIBUTION PT POTENTIAL TRANSFORMER SIMILAR ITEMS FOR A COMPLETE INSTALLATION. PROVIDE ITEMS ELECTRICAL EQUIPMENT, RACEWAYS, AND OTHER O (� <br /> DSL DIGITAL SUBSCRIBER LINE PVC POLYVINYL CHLORIDE NECESSARY FOR COMPLETE AND OPERATIONAL ELECTRICAL COMPONENTS. � � �LI <br /> SYSTEM. B. DIVISION 26 SHALL COORDINATE THE SUPPORT SYSTEMS AND C� <br /> DWG DRAWiNG DESIGN LOADS FOR HUNG RACEWAYS AND OTHER � � W <br /> RCP REFLECTED CEILING PLAN 12. BRANCH CIRCUIT HOMERUNS ARE SHOWN TO INDICATE CIRCUIT ELECTRICAL SYSTEMS (INCLUDING COMBINED MULTIPLE � , <br /> (E) EXISTING REC RECEPTACLE PROPERTIES AND CONFIGURATION. SINGLE-CIRCUIT HOMERUNS MAY RACEWAY RUNS) WITH THE GENERAL CONTRACTOR AND THE � � L�I.� <br /> EA EACH REF REFER TO BE COMBINED IN ACCORDANCE WITH THE SPECIFICATIONS, UP TO A STEEL AND WOOD JOIST MANUFACTURERS IN ADDITION TO � � <br /> REV REVISION MAXIMUM OF FOUR 4 CIRCUITS SERVED FROM SAME PANELBOA D � � <br /> EF EXHAUST FAN ( ) R , OTHER TRADES THAT MAY BE IMPACTED. � �LI <br /> EIA ELECTRONIG INDUSTRIES ASSOCIATION RM ROOM UNLESS INDiCATED OTHERWISE. EXTEND AND CONNECT BRANCH � I`� (� <br /> ELEV ELEVATION RU RACKUNIT CIRCUIT RACEWAY AND WIRING FROM HOMERUN TO DEVICES AND �� � Z �„�,,, • <br /> EM EMERGENCY EQUIPMENT WITH CIRCUIT NUMBERS INDICATED. CONDUCTOR , � � <br /> QUANTITIES AND SIZES ARE INDICATED AT HOMERUNS ONLY. SHOW <br /> EMT ELECTRICAL METALLIC TUBING SHT SHEET ACTUAL RACEWAY ROUTING AND CIRCUITING ON RECORD � <br /> ENCL ENCLOSURE SLC SIGNALING LINE CIRCUIT DRAWINGS. MINIMUM CONDUCTOR SIZE#12 AWG. � � � <br /> SM SINGLEMODE O � ~ <br /> EPM ELECTRONIC POWER METER (� <br /> EPO EMERGENCY POWER OFF SMFC SURFACE MOUNTED OPTICAL FIBER CABINET 13. LIGHT FIXTURES MOUNTED IN CONTINUOUS ROWS SHALL BE O <br /> SMR SURFACE METAL RACEW THROUGH-WIRED VIA FIXTURE INTERNAL WIREWAYS. CIRCUITS AS � �: <br /> EQUIP EQUIPMENT AY INDICATED ON DRAWINGS. FIXTURES NOT LISTED FOR THROUGH ~ I� <br /> ETR EXISTING TO REMAIN SONET SYNCHRONOUS OPTICAL NETWORK W�RING SHALL BE WIRED VIA SEPARATE RACEWAY AND WIRING O Q � <br /> EWC E�ECTRIC WATER COOLER SP SERVICE PROVIDER SYSTEM EXTERNAL TO THE FIXTURES. PROVIDE RACEWAYS WIRING � � <br /> SPEC SPECIFICATIONS AND CONNECTIONS FOR A COMPLETE AND OPERATIONAL SYSTEM. Z 4 N <br /> F FUSE;DEGREES FAHRENHEIT SPST SINGLE POLE SINGLE THROW O � <br /> FA FfRE ALARM ST SHUNT TRIP ENERGY CODE NOTES � � � <br /> FAAP FIRE ALARM ANNUNCIATOR PANEL STP SHIELDED TWISTED PAIR <br /> FACP FIRE ALARM CONTROL PANEL SVGA SUPER VIDEO GRAPHICS ARRAY <br /> SW SWITCH 1. RECORD DRAWINGS: SUBMIT TO THE BUILDING OWNER PER ENERGY <br /> FBO FURNISHED BY OWNER CODE ENFORCED BY THE LOCAL AHJ. <br /> FOIC FURNISHED BY OWNER INSTALLED BY SWBD SWITCHBOARD <br /> CONTRACTOR 2. OPERATION AND MAINTENANCE MANUALS: SUBMIT TO THE BUILDING <br /> FO10 FURNISHED BY OWNER WSTALLED BY OWNER TBB TELECOMMUNICATIONS BONDWG BACKBONE OWNER PER ENERGY CODE ENFORCED BY THE LOCAL AHJ. AB B R E V I AT I 0 N S <br /> TEL TELEPHONE <br /> FSD FIRE SMOKE DAMPER TELCO TELEPHONE COMPANY 3. THIS BUILDING AND ITS ENERGY SYSTEMS HAVE BEEN DESIGNED TO AN D G E N E RAL <br /> TGB TELECOMMUNICATIONS GROUNDING BUSBAR COMPLY WITH ENERGY CODE ENFORCED BY THE LOCAL AHJ. <br /> G GROUND CONTRACTOR IS RESPONSIBLE FOR CORRECT INSTALLATION OF N OTE S <br /> GFI GROUND FAULT INTERRUPTER TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION ENERGY CONSERVATION MEASURES. <br /> GFCI GROUND FAULT CIRCUIT INTERRUPTER TMGB TELECOMMUNICATIONS MAIN GROUNDING 4. LIGHTING CONTROL SYSTEMS COMMISSIONING AND COMPLETION <br /> GND GROUND BUSBAR REQUIREMENTS: TEST SYSTEMS TO ENSURE THAT BUILDING <br /> GRS GALVANIZED RIGID STEEL TP TAMPER PROOF SYSTEMS HAVE BEEN INSTALLED AND FUNCTION PRC7PERLY, <br /> TR TELECOMMUNICATIONS ROOM EFFICIENTLY AND CAN BE MAINTAINED IN ACCORDANCE WITH THE <br /> HC HORIZONTAL CROSS CONNECT TTB TELEPHONE TERMINAL BOARD CONTRACT DOCUMENTS AND OPERATIONAL REQUIREMENTS PER <br /> HID HIGH INTENSITY DISCHARGE TV TELEVISION ENERGY CODE ENFORCED BY THE AHJ. <br /> HP HORSEPOWER TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION <br /> HTR HEATER TYP TYPICAL <br /> Hz HERTZ <br /> UG UNDERGROUND <br /> IC INTERMEDtATE CROSS CONNECT UL UNDERWRITERS LABORATORIES <br /> IBC INTERNATIONAL BUILDING CODE UON UNLESS OTHERWISE NOTED ' <br /> IDF INTERMEQIATE DISTRIBUTI(�N FRAME UPS UNINTERRUPTIBLE POWER SUPPLY <br /> INSTITUTE OF ELECTRICAL AND ELECTRONiC UTP UNSHIELDED TWISTED PAIR <br /> IEEE ENGINEERS W UNIT VENTILATOR <br /> IG ISOLATED GROUND <br /> IMC INTERMEDIATE METALLIC CONDUIT V VOLTS <br /> ISDN INTEGRATED SERVICES DIGITAL NETWORK VA VOLT AMPERES <br /> VFD VARIABLE FREQUENCY DRIVE <br /> J JUNCTION <br /> W WATT; WIRE <br /> kVA KILOVOLT AMPERE W/ WITH <br /> kW KILOWATT W/O WITHOUT ' <br /> KCMIL THOUSAND CIRCULAR MILS WA WORKSTATION AREA ISSUE DATE: <br /> KVAR KILOVOLT AMPERE REACTIVE WAN WIDE AREA NETWORK _„_ ____ 1 2 , 02 1 6 <br /> WG WIRE GUARD <br /> DRAWN BY: CT <br /> LAN LOCAL AREA NETWORK WH WATT HOUR METER CHECKED BY: M� <br /> LCP LIGHTING CONTROL PANEL WP WEATHERPROOF <br /> LEC LOCAL EXCHANGE CARRIER PROJECT NUMBER <br /> LT LIGHT XMFR TRANSFORMER <br /> LTG LIGHTING �1606 <br /> Y WYE <br /> M METER <br /> MAN METROPOLITAN ARER NETWORK Z IMPEDANCE — � <br /> MAx MAxI�uM SHEET NUMBER <br /> E0.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.