i
<br /> I . : �� i1! ,
<br /> ° CENERAL POWER ONE LINE DIAGRAM '; GROUNDING DRAWING INDEX � ,
<br /> �, �" ,
<br /> _ , �
<br /> � ���-- EXISTING ELECTRICAL TO BE REMOVED � SWITCHBOARDISWITCHGEAR ---- EQUIPMENT ENCLOSURE —�— GROUNDING CONDUCTOR E0.1 LEGEND AND DRAWING INDEX `� ',
<br /> ,� / / ��
<br /> ; � E0.2 ABBREVIATIONS AND GENERAL NOTES �
<br /> EXISTING ELECTRICAL TO REMAIN ���:�:.: PANELBOARD, FL.USH MOUNTED — BUS Q GROUND ROD ; �� �
<br /> - -i-' E0.3 LIGHT FIXTURE SCHEDULE A�
<br /> ��
<br /> � -�-�-��-- PANELBOARD, SURFACE MOUNTED WIRE �--g GF�OUNDING BUSBAR t�,j ,
<br /> NEW ELECTRICAL WORK .�._ ,
<br /> E0.4 MECHANICAL EQUIPMENT SCHEDULE
<br /> � � � • �-� �
<br /> , � � � � � 2d�3 < <����r�c r I_L��� �.'v� � -
<br /> MATCHLINE OR PROPERTY LINE ��-�FRONT) —�- TERMINAL/ LUG � EQUIPMENT GROUNDING CONNECTION .; E1.1D , FIRST FLOOR DEMOLITION PLAN E-v4 � � �"�, ���f {�.� �i:�1
<br /> � — � - u TRANSFORMER
<br /> � � � � � � � � �� - � E2.1A FIRST FLOOR LlGHTING PLAN � � +�� �'����� �,��� � ��� %���'���
<br /> �,
<br /> . . �. .I'nh. -rr_�?._l� ���(J�r�� � �..
<br /> - - -- - ENLARGED PLAN BOUNDARY � MOTOR CONNECTION. --�— CONNECTION '
<br /> �, GROUNDING STRAP E2.1 B FIRST FLOOR LIGHTING CONTROLS
<br /> �, DISCONNECT SWITCH, NON FUSED Q DELTA , � E3.0 FIRST FLOOR OVERALL POWER PLAN H A .R G I S '
<br /> � DETAIL/PLAN IDENTIFIER : "
<br /> E�.� 0, DISCONNECT SWITCH, FUSED � WYE " ' E3.1 FIRST FLOOR POWER PLAN '
<br /> Hargis Englneers,Inc.
<br /> A nn� POWER TRANSFORME2 E4.1 FIRST FLOOR MECHANICAL POWER PLAN 1201 ThiFd Avenue, Suite 6fl0 j
<br /> ' SECTION IDENTIFIER �+ ENCLOSED CIRCUIT BREAKER Seattls,WA981Q1 I
<br /> E1.1
<br /> , E4.2 ROOF MECHANICAL POWER PLAN t� 2ae.44s.337s !
<br /> , vF� VARIABLE FREQUENCY DRIVE � CURRENT TRANSFORMER
<br /> A LEVATION IDENTIFIER E7.1 ENLARGED PLANS f�206.448.4450 '
<br /> � E�.� E $ MANUAL MOTOR STARTER WITH THERMAL _ _ w( hargis.biz
<br /> M OVERLOADS I— p—I E8.1 ELECTRICAL DETAILS `
<br /> � REVISION DEFINITION AREA, AREA ENCIRCLED ,, � � � TRANSFER SWITCH
<br /> I ° CONTAINS CHANGES MADE SUBSEQUENT TO �, COMBINATION STARTERiDISCONNECT � � � ' ED9.1 NOT USED
<br /> PREVIOUS ISSUE � _ _ �
<br /> UIT BREAKER FIXED E9.1 ONE-LINE DIAGRAM NORMAL POWER `�.� �;���,.; � .
<br /> � MAGNETIC STARTER o- -o CIRC , , �''��-.� �
<br /> v ; E9.2 ONE-LINE DIAGRAM EMERGENCY POWER `�_ �. �
<br /> i Q REVISION CALLOUT `° `-� � �
<br /> 1 EQUIPMENT CONNECTION. CONFIRM CONNECTION -{���} CIRCUIT BREAKER, DRAWOUT , E9.3 FEEDER SCHEDULE � � �
<br /> - � FLAG NOTE TAG � WITH EQUIPMENT MANUFACTURER ! . � '
<br /> �� i �
<br /> � DISCONNECT SWITCH E10.1 PANEL SCHEDULES Q`.
<br /> O DEMOLITION NOTE TAG QF�S FIRE/SMOKE DAMPER 3
<br /> �-�- FUSED SWITCH
<br /> O EQUIPMENT TAG a PUSHBUTTON CONTROLLER ' �
<br /> (SINGLE OR MU�TIPLE BUTTONS) � FUSE a
<br /> �
<br /> aHu-o� MECHANICAL EQUIPMENT TAG _ '
<br /> � �--
<br /> , H EMERGENCY POWER OFF PUSHBUTTON ,"� FUSED CUTOUTS � w
<br /> � MECHANICAL EQUIPMENT TAG 4 CIRCUIT BREAKER WITH GROUND FAULT � t,=!) � '
<br /> AHU RECEPTACLES GF {
<br /> PROTECTION H -� ~
<br /> GF� DEVICE SUBSCRIPTS $ W z W
<br /> � N NORTH ARRO W �� S T C I R C U I T B R E A K E R W I T H S H U N T T R I P O P E R A T O R �
<br /> +42" �2 (G F I,W P,I G O R O T H E R S U B S C R I P T) �� i � � a
<br /> �(CIRCUIT NUMBER) '
<br /> (NON-STANDARD MOUNTING HEIGHT} �
<br /> � LOCATION WHERE PICTURE WAS TAKEN AND U G F - ;
<br /> �:/ DIRECTION � DUPLEX RECEPTACLE ON UPS POWER FUSED SWITCH WITH GROUND FAULT PROTECTION
<br /> � �
<br /> G � W
<br /> � DUPLEX RECEPTACLE ON GENERAYOR POWER ~ � �
<br /> � �
<br /> LIGHTING ...� SPECIAL RECEPTACLE K {Q(K�{4 CIRCUIT BREAKERS WITH KEYED INTERLOCK � � �
<br /> A � b_Y b
<br /> � DEVICE SUBSCRIPTS � DUP�EX RECEPTACLE ; �
<br /> � '' z
<br /> 12ab (�i�HT FixTURE n`PE> � FOURPLEX RECEPTACLE /�/ MOTOR CONNE�TION
<br /> i �-(CIRCUtT NUMBER/SWITCHLEG) ; ` '
<br /> � � DUP�EX RECEPTACLE, ABOVE GOUNTER ` '
<br /> �MOUNTED 4"TO CENTERLINE ABOVE BACKSPLASH) � GENERATOR
<br /> 0 ,
<br /> � L�IGHTING FIXTURES � FOURPLEX RECEPTACLE, ABOVE COUNTER O METER ,
<br /> � (MOUNTED 4"TO CENTERLINE ABOVE BACKSPLASH.}
<br /> , (REFER TO LIGHTWG FIXTURE SCHEDULE r n
<br /> - FORa�oiTioNa,�wFORMarioN� SPLIT WIRED DUPLEX RECEPTACLE H WATT HOUR METER V � � ,
<br /> � � Q z ,
<br /> o ❑ � �
<br /> � - ��- DROP CORD RECEPTACLE �q AMMETER ' �"'� �
<br /> f--�--� STRIP LIGHTING FIXTURE �(;�AYs AND �OXES
<br /> 0 � �
<br /> VO VOLTMETER --� � �� Q
<br /> �}I I� WALL-MOUNTED LIGHTING FIXTURE � JUNCTION BOX ' \ '.
<br /> � o ~ W
<br /> ST SHUNT TRIP � z � / � '
<br /> , QF FURNITURE WALL FEED OUTLET BOX O , a � (� O
<br /> C� , > � `
<br /> PULL BOX GF GROUND FAULT PROTECTION - � ( � �^ ��n
<br /> Pg �WHERE INDICATED,SUBCRIPT INDIGATES PULL BflX NUMBER) � O , s � `�✓ / W "' '
<br /> � � ' � �
<br /> : = MANHOLE EPM ELECTROIviC POWER METER
<br /> EMERGENCY LIGHTING FIXTURES �O � ' p u � Z W
<br /> , �"�'#� (REFER T O L I G H T I N G F I X T U R E S C H E D U L E � �WHERE INDICATED,SUBCRIPT INDICATES MANHOLE NUMBER) O �� � �
<br /> FOR ADDITIONAL INFORMATION) SPD SURGE PROTECTIVE DEVICE � � ~ H � �
<br /> HH HANDHOLE � , �. H .
<br /> _ f+ � . : �--� � �
<br /> UANTITY OF � FLOORBOX �SUBSCRIPT INDICATES TYPE,WHERE NO SUBSCRIPT, �- GROUND ��/
<br /> � POLE MOUNTED LIGHTING FIXTURE, Q A SEE SPECiFICATIONS} �
<br /> � ; L� L1J �
<br /> ;-1EADS AS INDICATED.
<br /> O POKETHRU tSUBSCRIPT INDICATES TYPE,WHERE NO SUBSCRIPT, 12,241 AVAILABLE FAULT CURRENT (SYMMETRICAL)TAG � (I� .
<br /> � q SEE SPECfFICATIONS) O _
<br /> �O{] DOUBLE HEAD, POLE MOUNTED, LIGHTING FIXTURE , � � ,
<br /> m POWER POLE, FLOOR TO CEILING 225 FEEDER TAG O =
<br /> ���+ LIGHTING TRACK WITH FIXTURES , �" �
<br /> � SURFACE METAL RACEWAY '
<br /> � SELF-CONTAINED BATTERY POVVERED EMEFZGENCY '
<br /> LIGHTING FIXTURE - RACEWAY CONCEALED IN WALL OR IN CEILING
<br /> � (EXPOSED IN UNFINISHEDAREAS� � PRIMARY SWITCH
<br /> � EXIT SIGN, UNIVERSAL MOUNTING �-- RACEWAY RUN BELOW FLOOR OR BELOW GRADE
<br /> (SHADED AREA INDICATES DIRECTION ARROWS) S H E ET TITLE:
<br /> LEGEND AND DRAWING
<br /> � ` �- FLEXIBLE RACEWAY =��
<br /> EXIT SIGN, WALI.MOUNTED _ _ INDEX
<br /> � � (SHADED AREA INDICATES DIRECTION ARROWS) RACEWAY (CfRCLE DENOTES VERTICAL ��-��� '
<br /> —� 1"RANSITION) � -��� ' ;
<br /> � � PAD MOUNT TRANSFORMER
<br /> OM OCCUPANCY SENSOR, CEILING MOUNTED _t� RqCEWAY CONTINUATION --K� , . I
<br /> X WHERE INDICATED, SUBSCRIPT INDICATES TYPE �— - - -�
<br /> , �
<br /> � OCCUPANCY SENSOR, WALL MOUNTED RACEWAY STUB WITH BUSHING _ _ '
<br /> ,: �� 480V
<br /> � PHOTOSENSOR C� �CEWAY SLEEVE WITH BUSHINGS � � � DATE: 04�08�1 6
<br /> ' , $W�TCHES � zosv � TRANSFORMER ,
<br /> `� EZ-PATH FIRE STOPPING SLEEVE ��_ '2ov ]OB NU.: 1 4008
<br /> �S, SWITCH, SPST UON UR AS DEFINED BY SUBSCRIPT CABLETRAY, 12"W x 4"H OVERHEAD, UNLESS �■��� I
<br /> a=SWITCH LEG T=TIMER OTHERWISE NOTED �
<br /> 3=THREE WAY C49C=MOMENTARY CONTACT ONE INCH AT FULL SCALE.
<br /> ' 4=FouR wa,Y P=Pi�oT uc�r CABLE TRAY, OVERHEAD LADDER TYPE ► � � IF NOT, SCALE ACCORDINGLY
<br /> K=KEYE� �v=�owvo�Ta.�E � � i PANELBOARD - MAIN LUGS ON�Y , SHEET: '
<br /> D=DIMMER OS=OCCUPANCY SENSOR -
<br /> LVM=LOW VOLTAGE PROGRAMMABLE HOMERUN TO Pt`�NEL L� ` ,
<br /> / HA_3 (WDICATES PANEL DESIGNATION AND ClRCUIT NUMBER)
<br /> � (a,b,c) OR (a-c) CAN BE USED TO DESiGNATE � '
<br /> � MULTIPLE SWITCHES. #10 -�...,_ � ,
<br /> � (GAUGE QF WIRE OTHER THAM AWG#12) ' ( � ■
<br /> �NUMBER OF CONDUCTORS � i � PANELBOARD - MAIN CIRCUIT BREAKER
<br /> ANY COMBINATION OF SWITCH TYPES CAN BE USED. �t�RouNo coN�ucTOR� �
<br /> , i (i.e. 3K = 3 WAY KEYED SWITCH) (PHasE coNo�cTORs� SHEET 56 OF 95
<br /> ., (NEUTRAL CONDUCTOR)
<br /> � _
<br /> � '
<br />
|