� 2 3 4 5
<br /> z
<br /> c�
<br /> �
<br /> W
<br /> �
<br /> 1301 First Avenue, Suite 301
<br /> Seattle, WA 98101
<br /> �1 R-25 BATT INSULATION
<br /> IGRIDI http://www.gglo.com
<br /> �1/2"
<br /> TYPICAL EXTERIOR WALL
<br /> SEE FLOOR PLANS
<br /> D �i AND WALL ASSEMBLIES p
<br /> ;II
<br /> B3
<br /> 2X8 STUD �:I',' A-5 1X PT FURRING STRIPS TO
<br /> FRAMING MATCH STUD SPACING 5141 `�"""""'"
<br /> il,� i21:(,I`��E /;t(�
<br /> I Rci- �ECT
<br /> Na • ♦
<br /> FINISH GRADE-SLOPE
<br /> , f � _ AWAY FROM BUILDING,TYP
<br /> g i 00 MtGH SHKOSK!
<br /> J ` � GRAVEL BACK FILL,4"MIN SZa OF WASHINGTON
<br /> �e d .
<br /> a�� I
<br /> w '� - ° — � EXTERIOR �Z��3� r7
<br /> � � FINISH F100R — ! I
<br /> > _ ; �. _ —
<br /> PER PLANS �
<br /> � SLAB ON � ;. o �" _ — 1"MIN R-5 VERTICAL RIGID
<br /> � a _ _ � INSULATION
<br /> �� GRADE � °� - �6"a ° ���
<br /> , �
<br /> �, INTERIOR ��� _�a �_. . � - 2"MIN PERIMETER R-10
<br /> ' ° < .aa �� — -- VERTICAL RIGID �
<br /> — — —-- — — — — — — — INSULATION
<br /> �_9 " . . . , . - , , d_. . .. - _ �
<br /> .d. �-�, ri . " - ' . ._d d.'. � . . ° , Q _ _
<br /> _� - ' . Q. , � . ° . � d "." � �r� _ _
<br /> p
<br /> o< o � ' ° a - � °a ° .° < 'ic. -- CONT WATERSTOP TYP @ •
<br /> - - 'a � . _ < -a - �
<br /> - - ' �_`< -6 - — � ALL COLD JOINTS
<br /> a . o _ a <:�_ - -= - —
<br /> a . - _ a< — —
<br /> .d- ' ,� � - " • . - - -
<br /> ad. _ ' . . " - . ' . _. - . � — _
<br /> '� - .. ° � ° "- ; ° .- - . . <- _ - —_— WATERPROOFING,
<br /> d "a.a ¢
<br /> a , ,a -. - - '_°�_ " - "d ; . .. . : - � — — EXTEND 6"BELOW
<br /> a - - .°d - -, _ _ o d : ` < Q �,_ --= COLD JOINT
<br /> a
<br /> . , .d - . " - +A ' , - , _
<br /> I—I I I , .. Q . ., q- a .
<br /> _ " 'd �� ._ _ —
<br /> " ' b = _, p ' �d• . _ � a. -.. " i � _ _
<br /> ° .' - q Q , a^ ", -o . < , <.� Qa a___, °, me . a- _—_ THICKENED SLAB PER PROJECT:
<br /> I —_ _ _, . . : °��� e a_ :<-�= _e.<. �_ e - X —i — STRUCTURAL
<br /> — - - � - ° Cocoon House Youth
<br /> _ — . 8. ' :� � . - " _ _ - _ _ ° � - -` a _ — — 4��PERF PVC PIPE
<br /> . - a - . .- . "�- "-„; .<� -I FOOTING DRAIN&
<br /> — � - - - - $ a"-a - � Q - ' - � � —� FILTER MATERIAL Center - Base Contract
<br /> < , _ - -a , a _ < C
<br /> C _ — - a ._ . - < , a "'-� �:. a< , �,_ CONNECT TO STORM
<br /> — — `'"a . DRAIN SYSTEM
<br /> <a�. _;_ _
<br /> — - a; - :< --
<br /> — — — � 'a.: � - .
<br /> _ a " . ' . ' '..a..� . ,ad� � . .�a : .i.. —
<br /> _ _ — I � � .a' _ � ! � — I I I I �� '_ .
<br /> — � � I � I � � ; i i_ I ,_ i — REINFORCED VAPOR
<br /> RETARDER
<br /> ^ TH I C KE N E D S LAB C U R B WAL L PROJECT ADDRESS:
<br /> C`� 1 1/2°_ ��-o° 3530 COLBY AVE.
<br /> 5 EVERETT,WA 98201 .
<br /> �R�� TYPICAL EXTERIOR WALL
<br /> �� SEE FLOOR PLANS
<br /> F►NISH FLOOR —, � AND WALL ASSEMBLIES OWNER:
<br /> PER PtANS !, COCOON HOUSE
<br /> A1 2gZg p�NE STREET
<br /> GRADEN �\' ,' ;� A-502
<br /> \ � t EVERETT, WA
<br /> � PATIO/ CONC SLAB-SLOPE 98201
<br /> INTERIOR �, ', i AWAY FROM BLDG 1/4"/
<br /> � � �� SIDEWALK FT MIN
<br /> � �_ _ � �_ a _ a
<br /> ' d . ri , a .- " . . . .:a' ' - ° " "4- "
<br /> " ' � _4' a ' Q a � e. - , q' 4 '- " � � . � .a "' , a . ..
<br /> - ' a - " , d� • . - o a� a" "' ' a4 �. . '_ . - . " ' �
<br /> � G� _ ..,Q� � �d . 6 Q� -Q a Q. `a � . � - .. . �
<br /> < �
<br /> ed_ ' , _ ' _ ' , _. - '
<br /> � - <a _ - " ' - - , " �x
<br /> 'eQ'
<br />� � ,� ;.. ' a �d-a" � . - a -. . .
<br /> �� � � �° . ?d .� ,a' _ ' , ad � a � a� `, � ' a � I I � I �—�
<br /> -° - ' - - � - � a � a. — — - 5 12113/2017 BASE CONTRACT PERMIT
<br /> .a - -. _ - a - - a — -
<br /> � � , �a ' ` _<.- — _ RESUBMITTAL
<br /> . - �a_ � _„ - ,. _ � . � < -
<br /> - � � _ _ �; P � , ad _ Q-,a� < �- � , - �'-0"MIN PERIMETER R-10 MARK DATE DESCRIPTIQN
<br /> B _ ° -� q q;. _ -. - - °` � : <-- - �ao a . �,< ` � __-VERTICAL RIGID
<br /> — — °'� � - - — — - INSULATION B REVISIONS
<br /> - - - " � a• ,a , _ .. < , - -
<br /> . _ - -° a< „ `- a �- -
<br /> Q _ a
<br /> ° , "_ a . _ - - � . d'� . '"
<br /> — — 8: ° - " � - ` � .��° i '— -4"PERF PVC PIPE
<br /> . o a. ' ,__ . : _<: - "-.. .< ,. < .. '.b.- ,<tl
<br /> — , - a a b � _ _ . = FOOTING DRAIN&
<br /> — � � � ° - -' , ° � ° _ `- - ° - ' FILTER MATERIAL
<br /> _ _ , . . - a <a � _ - _
<br /> _ — <� , ada :. , _ -- <- ,�a : < ". : - _ . ° -. a a <: — CONNECTTO STORM
<br /> — — a : �a ' a . °` � ..'a.: a., a°� _ ,e aQ. _a � — - DRAINSYSTEM
<br /> — < a_ —
<br /> J i i-i i i-i i i-i i i ,' a i i i-i i i i i i '-i i ; ' , , , i I I ,�, I I I i i i�i i i-
<br /> 1
<br /> REINFORCED VAPOR
<br /> RETARDER
<br /> THICKENED SLAB SIDEWALK/PATIO
<br /> B4BASE CONTRACT PERMIT
<br /> 1 1/2"= 1'-0" D 12l13/2017 RESUBMITTA�
<br /> ��
<br /> �R�� C 10/06/2017 PERMIT SET
<br /> / TYPICAL EXTERIOR WALL
<br /> FINISH FLOOR � SEE FLOOR PLANS B 09122l2017 BASE CONTRACT BID SET
<br /> PER PIANS AND WALLASSEMBLIES A 08/2512017 DESI�N DEVELOPMENT
<br /> SLAB ON � �` ��� 18 GA BLACK STAINLESS STEEL �
<br />� GRADE � Y I � MARK DATE DESCRIPTION
<br /> � 1 SHEET METAL
<br /> � �� ISSUE INFORMATION
<br /> INTERIOR \ � EXTERIOR
<br /> — — — — — — — — — — � 63
<br /> A-502 THICKEND SLAB PER
<br /> � 2016030 00
<br /> _ � 9 , . . . _ . _. . 'd. � .
<br /> °" a ` ` � , � . ���a� . < STRUCTURAL
<br /> , 4 � ° ° a° a < . < ° a ' � °° z FINISH GRADE-SLOPE PROJECT NO.: •
<br /> - a a - - °- . ,� -�Q <�_ a� - - .� . ` � � AWAY FROM BUIIDING,TYP GGLO PRINCIPAL IN CHARGE: Michaei Wishkoski
<br /> _,°�� a_ �: � _ - � _ � ; �a'_� - co
<br /> °a ,a_�-� -, " � - . ' - - - -� '° - - GRAVEL BACK FILL,4"MIN GGLO PROJECT MANAGER: Scott Schreffler
<br /> � a
<br /> `` o-q _ - ": _ � �°. , -. .�a._d" °d : p - _ � �... OWNERAPPROVAL:
<br /> < < � W
<br /> \ � - - a6 , ' _ - . ' d a , ' a - .
<br /> A \ ° �Q_ -_ - °. : -� �.- -a4 _ _ _ — `I/w'
<br /> dd � d l _I
<br /> I I I I �d �
<br /> Q aad .a -
<br /> . - < _ — A
<br /> . <a� . .
<br />� _ ' e. � � ,a a, Pa - ' a- d �� ' - e , � � I 2'-0"MIN PERIMETER R-10 � .
<br /> � _ ° a �a' '"e . , - - :<� ° = �<' `_a = VERTICAL RIGID � SHEET TITLE
<br /> - °' - � � � - - — — INSULATION �/
<br /> — a, :. _� a _ - � � � ,—_— EXTERIOR DETAILS -
<br /> — - . `" . - p ` � — — ,,,,i
<br /> _ _ - a e ° a :a, a , a.
<br /> . �� -' a 'u �qa �d - � �— 4"PERF PVC PIPE a- FOUNDATION
<br /> � � . � Q � _ FOOTING DRAIN& �
<br /> — = $� �.a� ` _
<br /> — — � � � "' " ° � °< `� — FILTER MATERIAL (�
<br /> � __ - ^ : ; _ - a <a - - ` -- —
<br /> � _ ° ° Y CONNECT TO STORM
<br /> < _ _ daa d�"- . ,
<br /> .�d�' ' , . - � —
<br /> g —_ — - .a a , . °� < ° a < = DRAIN SYSTEM �
<br /> I — , — -a.= � _ — �""
<br /> ° SHEET N0.
<br /> � � —1 ! i I I 1— Z
<br /> < _
<br /> �
<br /> � �
<br /> ,
<br /> � � � " � REINFORCED VAPOR O
<br /> � T H I C KE N E D S LA B G RA D E RETARDER W A-5O�I
<br /> �
<br /> �
<br />� �
<br /> 0 1 1/2"= 1'-0"
<br /> a m COPYRIGHT GGLO.ALL RIGHTS RESERVED.
<br /> ORIGINAL SHEET SIZE IS 24"X36"
<br /> � 2 3 4 5
<br />
|