<br /> � ' � BEAD OF SEALANT METAL B KET CONTINUOUS WRB /— SIDING PER ELEVATIONS
<br /> WEATHER RESISTIVE BARRIER ' � i � WRB TAPE AT TOP OF CONT BEAD OF SEALANT
<br /> ' SEALED @ ENDS WITH WRB TAPE, WALL CAP ITH LOUVERS �' ' PLASTIC FLASHING RAINSCREEN STRAPPING Z
<br /> EXTER�OR i I � TyP SIDING PER ELEVATION U
<br /> ,�-- SIDING PER ELEVATIONS ! � SLOPE TO 1/2"/1'-0" � ' ' / WEATHER RESISTNE BARRIER N
<br /> i
<br /> I SIDING PER ELEVATION /— i � RAINSCREEN STRAPPING LAP OVER METAL FLASHING
<br /> w
<br /> / - DOWNSPOUT Z ' , I l METAL BRACKET r �- VENT H00 ' � i � �
<br /> � P I P E C L A M P 4 8"M A X � ! INSECT SCREEN � � i C 3 �� �� � V E R T B A T T E N B E Y O N D
<br /> i @ �, ; , i� TYP BLO CKIN G SIZE TO FIT Z �-
<br /> ; B E T W E E N S U P P O R T S � I SHEET METAL FLASHING i � � A-5 0 2 � I M O U N T I N G R E Q'D �
<br /> / � � � _ - WRB TAPE 1301 First Avenue, Suite 301
<br /> METAL FLASHING WI � Seattie, WA 98101
<br /> ; 1X BLOCKING �' � ' I �— SEALANT JOINT BETWEEN I I � � HEMMED DRIP EDGE INSECT SCREEN
<br /> � I : TERMINATION CAP&DUCT � � i ��
<br /> � WEATHER RESISTNE - METAL BRACKET.24 GAGE � � ��� ' � i http://www.gglo.com
<br /> � � �� i � — FLANGE SET IN SEALANT �� PER ELEVATION
<br /> BARRIER — PRE-FINISHED METAL � i �
<br /> , i BRACKET FLASHING I � ' i ,J I- SEAL AROUND PIPE `-�
<br /> EXTERtOR WALL PER PLANS i i i �� � �,' �� i PENETRATION WITH SEALANT ' METAL FLASHING W/HEMMED
<br /> _ _ _. _ _ _ i � VENT HOOD,24 GAGE PRE- �, , � `
<br /> �-� - - .. -
<br /> __ _.
<br /> � -- - - - � � FINISHED METAL.SECURE WITH � � � , DRIP EDGE,SEE C3/A-502 DETAIL
<br /> � ' � / � FOR TYP DIMENSIONS �
<br /> / �� � i i �� i EXPOSED FASTENERS / � i -� ��
<br /> 2x BLOCKING AT
<br /> , ; � UNSUPPORTED ' �— SET WEATHER RESISTIVE , I � P��c5x �� i � � �— CONT 21/2"X 3!4"BATTEN � � ^
<br /> I HOSE BIB 5141
<br /> / RAINSCREEN , � BARRIER IN A BED OF SEALANT - - � / `� � I i
<br /> VERT BATTEN BEYOND K+�A(,t '•';�e:D
<br /> �r�1��t-iY��Cfi
<br /> � STRAPPING i I� � @ DUCT PENETRATION � i I -- CEMENTITIOUS TRIM BLOCK � , }
<br /> \ ' �� '-+� �' ! � EXTEND WEATHER RESISTIVE �
<br /> INSULATE CAVITY � � � � � pLASTIC WALL CAP WITH � , ; i � ' BARRIER UP BEHIND FLASHING 12"MIN � . :r/d ;'"_ �' �
<br /> „ � � /�,� ..,���.�� _.�_._...
<br /> � ��� � LOUVERS 3 ����i ( � �e.�s`'...�_ �` ` /
<br /> I „ , � 1/8"SEALANT JOINT i FIBER CEMENT SIDING MlCH ��,�V�rfSHKOSKI
<br /> h'� ' DRIP FLASHING ON BOOT INSULATE PIPE IN EXTERIOR WALL, i ' STAT dF WASHINGTON
<br /> , ; , ; i
<br /> �; i I MTL FLANGE SET IN CONT BEAD OF *AT FC RAINSCREEN TYPE 1 , , TYP � RAINSCREEN STRAPPING � ,7
<br /> .
<br /> � SEALANT KITCHEN RANGE EXHAUST=22"WIDE �' 1�'��''� r
<br /> �� � � SINGLE BATHROOM OR DRYER EXHAUST= 10"WIDE �"� � '� i 1 � PREFORMED PLASTIC AND RUBBER �
<br /> ' WEATHER RESISTIVE BARRIER DOUBLE BATHROOM OF DRYER EXHAUST=22"WIDE � �'� � ' F L A S H I N G S E T I N S E A L A N T T H R W A L L F L A S H I N G @
<br /> WRB TAPE S E E M E C H A N I C A L F O R V E N T T Y P E S
<br /> D�W N S P OU T WALL CAP WITH VENT HOOD ATFCRAINSCREENTYPE2 F H��IG AT HOSE BIB R A I N S C R E E N 1
<br /> REFER TO ELEVATIONS /�
<br /> D 1 5 3�� - ,�_o„
<br /> 3" = 1'-0" D� 3��= 1'-0�. D`T 3��= 1'-0" IDIN P
<br /> %
<br /> S G ER ELEVATIONS
<br /> / _--- WRB i
<br /> � � � � � � � VARIES
<br /> CONT BEAD OF SEALANT
<br /> / �` �� ' ' ' RAINSCREEN STRAPPING
<br /> V "°��� ; � SIDING PER ELEVATION i �-
<br /> _ � • , , 1 TYP BLOCKING SIZE TO FIT ��� WEATHER RESISTNE BARRIER
<br /> � � �� � � MOUNTING RE 'D � LAP OVER METAL FLASHING
<br /> � : �- - / - - -�- - - = - - - - - -'- - -/- - - - - - - - , i ! ,�' Q
<br /> ��� �
<br /> ( PREFINISHED SHEET METAL . i � �
<br /> ; �-FIBER CEMENTPANEL � FLASHING W/HEMMED DRiP � i j / �— METAL FLASHING W/
<br /> EDGE AND END DAMS i i I HEMMED DRIP EDGE I VERT BATTEN
<br /> &ALUM REVEAL OUTSIDE �. � i i �� z
<br /> CORNER TRIM,PAINTED � i I WRB TAPE �
<br /> � �' � � � % i ��� 15 DEGREE SLOPE ' � � - WRB TAPE �
<br /> �;�i � � � ALUMINUM REVEAL VERTICAL i �r� PER ELEVATIONS � � '; � i � �
<br /> , \ MOLDING TRIM;OCCURS AT
<br /> ': i RAINSCREEN 2 ONLY — SLOPE � ' i ; INSECT SCREEN PROJECT:
<br /> � L- C E M E N T I T I O U S S I D I N G P E R E L E V A T I O N S � �l'_ �---� PER ELEVATION r � i � PANCAKE BOX �
<br /> � ' � � ` �� PER ELEVATION COCOOI1 HOUS@ YOUtII
<br /> � ALUMINUM REVEAL INSIDE CORNER TRIM I I I . _ ' � i �_ � SEAL AROUND WIRE i
<br /> � STL POST PER STRUCTURAL � 5 _ i i PENETRATION WITH SEALANT � 45 DEGREE WEAHTER CUT Center - Base Contract
<br /> ���i CEMENTITIOUS SIDWG PER ELEVATIONS �-{ � � I - � � �� `� _ _ ' � Z-FLASHING C
<br /> C — WEATHER RESISTIVE BARR�ER-EXTEND ��"� i � �
<br /> ���i� � ���� � HOLE TO SUIT WIRING,SEAL AT ,
<br /> AROUND CORNERS 24°MW EACH SIDE i
<br /> , : i (NO VERTICAL JOWTS WITHIN 24"OF � I i � , BLOCKING PENETRATION �
<br /> ; �� DIMENSIONS TYPICAL, UNO� �� ��:�i ' CEMENTITIOUS TRIM BLOCK �� VERT BATTEN
<br /> CORNERS) ` RATED COLUMN WRAP i ( �i
<br /> 6"WIDE SELF ADHERED FLEXIBLE � - - - - �+ PER C1/A-535(UL i ' � i EXTEND WEATHER RESISTIVE
<br /> �,
<br /> i
<br /> � � �
<br /> MEMBRANE FLASHING CENTER ON DESIGN N0.X526) TYP TH RU WALL F LAS H I N G 1l8"SEALANT JOINT i BARRIER UP BEHIND FLASHING 12 MIN
<br /> ' i tNSIDE AND OUTSIDE CORNERS Cj3 � i
<br /> 3"= 1'-0" / � FIBER CEMENT SIDING
<br /> '-�i
<br /> � � � ��-���i � LIGHT FIXTURE ,
<br /> i � ; ALUMINUM REVEAL OUTSIDE CORNER TRIM
<br /> _____ __ . ' j 5 i PREFORMED PLASTIC AND RAINSCREEN STRAPPING
<br /> - - - - - J ,
<br /> PT RAINSCREEN �- PT STRAPPING WITH / � � ' RUBBER FLASHWG SET IN
<br /> STRAPPING @ 1/2"TYP %� I N S E C T S C R E E N @ SEALANT PROJECT ADDRESS:
<br /> �� � `��� � STRAPPING F LAS H I N G AT EXT L I G H T 5 H 0 R I Z J 0 I N T RA I N S C R E E N 1 3530 COLBY AVE.
<br /> RAI NSCREEN TYPES 2&3 TYP EXT COL WRAP % � � C4 „_ , �, � C5 „ , EVERETT,WA 98201
<br /> C1 5 �j2 ,� _ , ,� � / '' ( � BETWEOEN W B AND 3 - 1 -0 3 = 1 -0"
<br /> 3"= 1'-0" 3 - 1 -0 � � � SAM FOR AIR BARRIER
<br /> ' I � WRB, LAP OVER --- WRB
<br /> V � � �� METAL FLASHING , � � � � I OWNER:
<br /> , � � � ` i � =� i � � SIDING PER ELEVATION � ,� ; 'I � AIR BARRIER COCOON HOUSE
<br /> � , � , �� - �� � ,` �
<br /> ;. � _ �- � � ! 6°WIDE SAM PRESTRIP, � �— RAINSCREEN STRAPPING � � i /-- STAGGER RANDOM BUTT JOINTS Z929 PINE STREET
<br /> � � �- -'- - - - -_-- - -�- - -�- - -�- - - - �
<br /> lAP ONTO CONCRETE � � I�
<br /> ' ; � � � FOR AiR ga�RiER � i � � �, � EVERETT, WA
<br /> � `r — WRB TAPE C3 TYP �' � � TYP BLOCKING SIZE TO FIT �� , ' 9820�
<br /> � � � � �" � ° � i MOUNTING REQ'D ��
<br /> � � � - � � — GAtVANIZED&PRE- A-502 ' � i
<br /> �� � - � � �-� � �
<br /> �' I I � CEMENTITIOUS BATTEN STRIP a a � � FINISHED METAL FLASHING � ; i � � ,-�— WRB TAPE \ � 12°EXPOSED PROFILE FIBER
<br /> i I SPACED RANDOMLY PER 4 � W/HEMMED DRIP EDGE �(� i � � � j CEMENT PLANK, PAINTED,SEE
<br /> � a �� .; �a - _ _ _, SEALANT WITH BACKER ROD �;�; ! ' �.`,/ � , � / ELEVATIONS
<br /> � � � E L E V A T I O N S,N O T T O E X C E E D 2 4"O C ' ' °
<br /> CEMENTITIOUS SIDING PER ELEVATIONS � a �ao�" � �a�� � z �� ELASTOMERIC COATING �' �� � �-- �� � � ` � i i RAINSCREEN STRAPPING � �
<br /> � � �- � � - METAL FLASHING Wi HEMMED � � � � ,I �� �
<br /> !.�i CEMENTITIOUS CORNER TRIM � ;�a a �, ,�a � SILL SEALER FOAM GASKET , ���i i ii DRIP EDGE. FOLDED END DAMS � �I �
<br /> ;;i 3/4"x21f2",TYP U.N.O. � 9 ° � �a°� C° � � �.��i i ii @ BLOCKS AND OPENINGS � i : ''', %
<br /> PT PLATE i i i 5 12I1312017 BASE CONTRACT PERMiT
<br /> �'� CEMENTITIOUS SIDING PER ELEVATIONS - 1 � i i ii EXTERIOR ELECTRICAL ,�, RESUBMITTAL
<br /> '�� °� � CONCRETE CURB WALL � . i � MARK DATE DESCRIPTION
<br /> B ,�,��i WEATHER RESISTIVE BARRIER-EXTEND �, ° ` � 4 � � i OUTLET BOX �� � � I
<br /> i A R O U N D C O R N E R S 2 4 M I N E A C H S I D E(N O � �. 4 °a � , TERMINATION BAR , i �_ _J� � , B REVISIONS
<br /> . �
<br /> ; VERTICAL JOINTS WITHIN 24"OF CORNERS) — — - � , i
<br /> ��°� ° " � �tr ° -�<�a. � � � ; 18 GA. PRE FINISHED � � ,
<br /> ,,i ° �" d a � ' n ; — GALV. METAL � ' CEMENTITIOUS TRIM BLOCK '
<br /> � 6"WIDE SELF ADHERED FLEXIBLE ` $� Po — - � � � ` � � �
<br /> � MEMBRANE FLASHING CENTER ON � b - 2'-0"MIN PERiMETER R-10 � � � CONTINUOUS PRE-PR�MED
<br /> � � INSIDE AND OUTSIDE CORNERS � °. 'a �� � �4� a _ X � I I — VERTICAL R1GID INSULATION � � ; 118"SEALANT JOINT �.� �� � Z-FLASH
<br /> �
<br /> __ i � � � '
<br /> r., � �-
<br /> - - - - - -� ° 6_ B - ; Q ` ., - ; — - WATERPROOFING
<br /> �
<br /> , , � � , �
<br /> . - - - - - - - �
<br /> CEMENTITIOUS CORNER TRIM � � PREFORMED PLASTIC AND RUBBER ,
<br /> 3/4"x21/2",TYP U.N.O.
<br /> i FLASHING SET IN SEALANT ��
<br /> �
<br /> � : = � TYP FLA ; �
<br /> _ SHING CONCRETE
<br /> �'� PT RAINSCREEN ��
<br /> STRAPPING@1/2��nP CURB WALL FLASHING AT ELEC OUTLET HORIZ JOINT RAINSCREEN 3
<br /> RA I N S C R E E N TY P E 1 B 3 3"= 1�_o�� B4 3., _ ,,_o.. B 5 3" = 1�_a��
<br /> g� PT STRAPPING WITH
<br /> 3"= 1'-0" � INSECT SCREEN @ D 12/13/2017 BASE CONTRACT PERMIT
<br /> BOTTOM OF RESUBMITTAL
<br /> �— PT STRAPPWG WITH � STRAPPWG GL C 10/0612017 PERMIT SET
<br /> i
<br /> ; �� INSECT SCREEN� � I BEAD OF SEALANT �� i
<br /> WRB B 09/22/2017 BASE CONTRACT BID SET
<br /> � ; ( BOTTOM OF STRAPP G �' � BETWEEN WRB AND ; TYPICAL EXTERIOR WALL ` �
<br /> � SAM FOR AIR BARRIER � SEE FLOOR PLANS `' � I SIDING PER ELEVATION A 08125J2017 DESIGN DEVELOPMENT
<br /> BEAD OF SEALANT ' i
<br /> BETWEEN 1NRB AND � � WRB,LAP OVER AND WALL ASSEMBLIES � i I
<br /> SAM FOR AIR BARRI a \�/ � METAL FLASHING ,--- 1/4"GAP lN SHEATHING AT RAINSCREEN STRAPPING MARK DATE DESCRIPTION
<br /> � � WRB,LAP OVER ���. � j �.� ' � � FLOOR LINE � i���I � — TYP BLOCKING SIZE TO FIT ISSUE INFORMATION
<br /> METAL FLASHING 6"WIDE SAM PRESTRIP, � i �
<br /> BASE AND LAP ONTO CONCRETE � � \ r ' � MOUNTING REQ D _ _�
<br /> BASE AND FLOOR � ; _ 6"WIDE SAM PREST F100R FINISH � FOR AIR BARRIER � �
<br /> FINISH PER FINISH ��� � ��°�� �' i � _ � � FLOOR LEVEL � ,� ��i � � WRB TAPE !
<br /> LEGEND ' WRB TAPE PER FINISH � � � .
<br /> � LEGEND - - `� I WRB TAPE - ' �i ; � , PROJE T N .. 2016030.00
<br /> � I ' �� i w j I �i - '��i ; SEAL AROUND CONDUIT �, �I FIBER CEMENT PANEL,TYP C 0
<br /> � � �— GALVANIZED&PRE- z I, m � � �� � ���: � � ��� � � � �� GGLO PRINCIPAL IN CHARGE: Michael Wishkoski
<br /> 1 ; FiNISHED METAL FLASHING _,, i �
<br /> - -r-� � \ � w � CONDUIT SLOPE 10d � GGLO PROJECT MANAGER: Scott Schreffler
<br /> �_: '� � � W/HEMMED DRIP EDGE W �,
<br /> � �
<br /> o" a � _, ���� � ,�� �, �. � � � � � a EXTEND BATT INSULATION �� � � � OWNER APPROVAL:
<br /> e � � � GALVANIZED&PRE- _ � �s ��!— , ~
<br /> , e a `; _ � ' o � � AT FLOOR JOIST � METAL TRIM HORIZONTAL REVEAL W
<br /> � - a a e � FINISHED METAL a � , - �.� `� � z � ��� �
<br /> � _ , a. � . � a ����� k ;'� p PERIMETER - � � i � ;' V�
<br /> a � , � ,
<br /> °a � I,
<br /> A a a e,
<br /> �
<br /> z �
<br /> � o FLASHING W/HEMM - � a �
<br /> �'° � � ._ � � ,._ _ a: : 4 �, � � a -. �� �a-� ,��;'� g , 18 GA.BLACK v w � � i � � i � �• A
<br /> a � ° < a DRIP EDGE SET IN C T a i �
<br /> � � � � � �� a � ° - � BED OF SEALANT a � � ��a��° �_. � a � �� �'� � I STAINLESS STEEL � u� � � ��, ��� �� i ����� t � SHEET TITLE
<br /> - � a °� a.� � 9- a � � SHEET METAL ,'� ��� � I � i WIRING �
<br /> �` ° � ° �� �� � � SILL SEALER FOAM � �� , _` � ��� ��� � `�' �� �� �; � ',� �, i � ���� RAINSCREEN FURRING �
<br /> – a� _ -� �� a � � � — — ; EXTERIOR WALL
<br /> , � � , � � �a . ,�a� f,� GASKET � � - ��a� o � Qaq �a �� � �'� � ; '— � SILL SEALER FOAM�ASKET � � �!���� -- SPRAY FOAM TO FILt CONDUIT �I � DETAILS
<br /> °�°- ' ° °- - PT P T a � a '` ; i I— �� � AROUND WIRING �� � �I
<br /> " a° �a �_ � . � �. ; LP' E a , � 9 a �� — -�., PT PLATE � � �'� � � 'I' C�
<br /> � � � °�- ��a �� a � " � �;n - THICKENED SLAB �a . � � � � �� — - ��, i ��� , PREFORMED PLASTIC AND RUBBER �� I
<br /> i
<br /> �
<br /> �
<br /> � � �" � - � a %� k °a �� � � �'� _ THICKEN�D SLAB � � FLASHING SET IN SEALANT ��,
<br /> � � a a= � , � _G �k�� 2'-0"MIN PERiMETER - _ " 4 a - ° � a ��i` i ' i °
<br /> � � - ��°�� a° ' °�a ; � _ 'a , �a ��� I I I--I 10 VERTICAL RIGID � � a � �" � � � '�r� ` - 2'-0"MIN PERIMETER R-10 -
<br /> � � � � ` �° — INSULATION ��� ° ` � 4 � � ��'� — ' '- VERTICAL RIGID INSULATIO � � �� � � SHEET N0.
<br /> � � 0
<br /> � TYP FLASHING SIDEWALK TYP FLASHING FOUNDATION TYP EXT WALL/FLOOR A-5OZ
<br /> W FLASHING AT CONDUIT HORIZ REVEAL RAINSCREEN �
<br /> � A1 A2 A3 A4 A5
<br /> 0 3"= 1'-0" 3„= 1'-0" 1 1/2" = 1'-0�, 5 , ,
<br /> 0 3„= 1'-0" 3�, = 1 -0' Q
<br /> a m COPYRIGHT GGLO.ALL RIGHTS RESERVED.
<br /> ORIGINAL SHEET SIZE IS 24"X36"
<br /> � 2 3 4 5