My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2112 RUCKER AVE BELSHAW APTS 2018-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
2112
>
BELSHAW APTS
>
2112 RUCKER AVE BELSHAW APTS 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2019 2:00:58 PM
Creation date
5/7/2019 1:59:17 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2112
Tenant Name
BELSHAW APTS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C C <br /> I sotesch, Nash & Na�� <br /> Architects, P.S. <br /> September 16, 2009 <br /> Steve Miller <br /> City of Everett <br /> 3200 Cedar Street Everett, WA 98201 <br /> RE: Owner: Belshaw, William T. <br /> Job Address: 2112 Rucker Ave. <br /> Plan Check No: B0908-035 <br /> Dear Mc Miller; <br /> The drawings have been amended (revision 1) to addmss your concem with regards to the following <br /> issues: <br /> 1. Steel furring channels are required on wall assembly UL263/U305. Item 6 should be included <br /> with the listing. <br /> Sheet A1.2—Revised to include Item 6 and Furring channels will be added in the Fire <br /> Rated Assembly UL 263/U305. <br /> 2. All fans should be shown on the plans in accordance with the 2006 VIAQ. <br /> Shect A1.0 and Al.l-Revised to show ceiling fans in the following locations: bathrooms, <br /> laundry rooms and kitchens. <br /> 3. Fans penetrating the ceiling of rated horizontal assemblies must comply with IBC 716.6.2. See <br /> enclosed construction tip sheet. <br /> Shcet A1.2-Reviscd to add the following Details: <br /> No 4-Cciling Fan Detail and <br /> No. 6-Firc Dampers at Rated Cciling Assembly <br /> 4. The plans should include the requirement for wiring the smoke detecrors in accordance with IBC <br /> 907.2.10. <br /> Shcets A1.0 and Al.l Revised. Legend amended to include the following notations: <br /> -Smoke Detectors (SD) listcd smoke elarms to comply with UL 217 shall be installed <br /> according to IBC 907.2.10 and thc household firc-warning equipment provisions ot <br /> NFPA 72. <br /> - Cciling Fans(CF) install cciling fans in compliancc with IBC 716.6.2 in conjunction with <br /> Details 4 and 6 on A1.2. <br /> Hoping this revisions will address your concerns. D ���� " " <br /> D <br /> S i n c c r e� SEP l 8 2��9 <br /> Pel�ano (F lix) Mangulabnan <br /> c�Per�it Ser�vices T <br /> 2727 Oakes Avenue,Sutte 100•Everett.WA 98201•425-259-0868•877-857-8972•bnh�lmharch.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.