My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
915 WALL ST 2019-05-22
>
Address Records
>
WALL ST
>
915
>
915 WALL ST 2019-05-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/22/2019 8:43:30 AM
Creation date
5/22/2019 8:43:09 AM
Metadata
Fields
Template:
Address Document
Street Name
WALL ST
Street Number
915
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
145
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IFC 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated <br /> construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, <br /> floors, fire-resis tive coatings and sprayed fire-resistant materials applied to structural <br /> members and fire-resistant joint systems) shall be maintained. Such elements shall be <br /> visually inspected by the owner annually and properly repaired, restored or replaced <br /> when damaged, altered, breached or penetrated. Where concealed, such elements shall <br /> not be required to be visually inspected by the owner unless the concealed space is <br /> accessible by the removal or movement of a panel, access door, ceiling tile or similar <br /> movable entry to the space. Openings made therein for the passage of pipes, electrical <br /> conduit, wires, ducts, air transfer openings and holes made for any reason shall be <br /> protected with approved methods capable of resisting the passage of smoke and fire. <br /> Openings through fire-resistance-rated assemblies shall be protected by self- or <br /> automatic-closing doors of approved construction meeting the fire protection <br /> requirements for the assembly. <br /> IFC 605.1 Abatement of Electrical Hazards <br /> Identified electrical hazards shall be abated. Identified hazardous electrical conditions in <br /> permanent wiring shall be brought to the attention of the responsible code official. <br /> Electrical wiring, devices, appliances and other equipment that is modified or damaged <br /> and constitutes an electrical shock or fire hazard shall not be used. <br /> EVERETT FIRE DEPARTMENT• 2930 Wetmore AVE STE 7A • Everett WA 98201 • (425)257-8120 • Fax(425)257-8139 Page 12 of 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.