My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5200 EVERGREEN WAY 2019-05-29
>
Address Records
>
EVERGREEN WAY
>
5200
>
5200 EVERGREEN WAY 2019-05-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2019 11:54:50 AM
Creation date
5/29/2019 10:32:21 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
5200
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Subsurface Exploration,Geologic Hazards,and <br /> Former Brien Ford Preliminary Geotechnical Engineering Report <br /> Everett, Washington Preliminary Design Recommendations <br /> conditions. The native and existing fill soils present onsite contained significant amounts of silt <br /> and are considered highly moisture-sensitive. On-site soils may only be reused in structural fill <br /> applications if specifically allowed by project plans and specifications, and if moisture <br /> conditions can be achieved that allow compaction to a firm and unyielding condition and to the <br /> specified minimum density for the application where they are used. If fill is placed during wet <br /> weather or if proper compaction cannot be obtained, a select import material consisting of a <br /> clean, free-draining gravel and/or sand should be used. Free-draining fill consists of <br /> non-organic soil with the amount of fine-grained material limited to 5 percent by weight when <br /> measured on the minus No. 4 sieve fraction with at least 25 percent retained on the No. 4 <br /> sieve. <br /> A representative from our firm should inspect the stripped subgrade and be present during <br /> placement of structural fill to observe the work and perform a representative number of <br /> in-place density tests. In this way, the adequacy of the earthwork may be evaluated as filling <br /> progresses, and any problem areas may be corrected at that time. It is important to <br /> understand that taking random compaction tests on a part-time basis will not assure uniformity <br /> or acceptable performance of a fill. As such, we are available to aid the owner in developing a <br /> suitable monitoring and testing program. <br /> 11.0 FOUNDATION UNDERPINNING <br /> Existing foundations located adjacent to the proposed excavation for environmental <br /> remediation at the project site will require underpinning for support during removal of <br /> contaminated soils. We anticipate that the foundation for the wall that separates commercial <br /> sales from the service intake building as well as the north end of the foundation of the auto <br /> detail shop will require underpinning. The subsurface explorations completed for this study <br /> and preceding studies encountered areas of variable surficial fill soils, ice-contact deposits, or <br /> dense native advance outwash sediments. Underpinning elements (pipe piles) should fully <br /> penetrate the existing fill soils and ice-contact deposits and be supported by the underlying <br /> outwash sediments. <br /> 11.1 Pipe Piles <br /> A deep foundation system consisting of small-diameter driven pipe piles may be used for <br /> foundation support where existing foundations will be undermined by the proposed <br /> excavation. The pipe piles should consist of Schedule 40 steel pipe, driven to refusal, which is <br /> defined as less than a given amount of penetration during a time interval of continuous driving <br /> using a hydraulic hammer. The time interval of continuous driving and the allowable pile load is <br /> dependent upon the pipe pile diameter and the weight of the driving hammer (see Table 1). At <br /> the request of the project structural engineer, we have provided design recommendations for <br /> 3-inch-diameter and 4-inch-diameter piles in Table 1. The depth of pile embedment into the <br /> May 16,2017 ASSOCIATED EARTH SCIENCES,INC. <br /> AWR/Id-160594V003-2-Projects120160594WV\WP Page 11 <br />