Laserfiche WebLink
Interior Lighting - Building Area Method LTG-INT-BLD <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Enhanced Services Facilities(ESF)+Retail Date 10/13/2017 <br /> Calculation O O Addition- O Addition For Building Department Use <br /> Area NOTE 8 stand alone +existing <br /> O Spaces where<50%of O Spaces where z 50%of O <br /> luminaires are replaced luminaires are replaced <br /> LPA 0 Standard O Additional Efficiency Package Option O <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting WattageNOTE 1 <br /> Location(plan#, Gross Interior Allowed Watts Allowed <br /> Building Area room#,or ALL) Area Description Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Dormitory E211,E213,E214 ESF Facility 6786 0.46 3122 <br /> Parking garage E211 Parking Garage 5055 0.16 809 <br /> Retail E211 Retail 3013 1.01 3044 <br /> Total 14854 <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts per <br /> Building Area room#) Fixture Description NOTE 2,a,a,s Fixtures Fixture NOTE 6 Watts Proposed <br /> Dormitory A 1x4 surface mtd,LED,1 bulb 14 39 546 <br /> Dormitory B 2x2 recessed troffer,LED,1 bulb 41 33 1353 <br /> Dormitory C Recessed downlight,LED,1 bulb 50 9 450 <br /> Dormitory C-Sleeping Units Recessed downlight,LED,1 bulb,C405.4.1 Ex.1.6 64 <br /> Dormitory D 2x4 surface mount,LED, 1 bulb 4 32 128 <br /> Dormitory E undercabinet light,LED,1 bulb 2 18 36 <br /> Dormitory F Ceiling fixture,LED,2 bulb 6 32 192 <br /> Dormitory G Ceiling fixture,LED,2 bulb 6 28 168 <br /> Dormitory H Wall sconce,LED,1 bulb 4 14 56 <br /> Dormitory I Pendant 1X4,LED, 1 bulb 3 32 96 <br /> Dormitory XA Emergency lighting,led,1 bulb,C405.4.1,Ex.1.2 7 <br /> Dormitory EX Exit sign,LED,1 bulb,C405.4.1,Ex.7 8 <br /> Parking garage A 1x4 surface mtd,LED,1 lamp 20 39 780 <br /> Parking garage C Recessed downlight,LED,1 lamp 2 9 18 <br /> Parking garage EX Exit sign,LED,1 bulb,C405.4.1,Ex.7 2 <br /> Retail A 1x4 surface mtd,LED, 1 lamp 2 39 78 <br /> Retail B 2x2 recessed troffer,LED, 1 lamp 7 33 231 <br /> Retail EX Exit sign,LED,1 bulb,C405.4.1,Ex.7 6 <br /> Compliance by Building Area NOTE 7 <br /> Total Allowed Total Proposed Interior Lighting <br /> Building Area Warnings Watts Watts Power Allowance <br /> Dormitory 3122 3025 <br /> Set Calculation <br /> Area <br /> Parking garage 809 798 <br /> Set Calculation <br /> Area <br /> Retail Confirm all fixtures are reported under proposed lighting-low watts 3044 309 Set Calculation <br /> relative to maximum allowed. Area <br /> Note 1-List all unique building areas per Table C405.4.2(1)that occur in the Totals 6 975 4132 <br /> project scope.Select building area category from drop down menu. <br /> Note 2-Proposed fixtures must be listed in the building area in which they occur.List all proposed lighting fixtures including exempt <br /> lighting equipment and existing-to-remain fixtures. <br />