Laserfiche WebLink
Exterior Lighting LTG-EXT <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Enhanced Services Facilities(ESF)+Retail Date 10/13/2017 <br /> Exterior Li htin For Building Department Use <br /> g g Q Zone 1 Q Zone 2 Q Zone 3 Q Zone 4 <br /> Zone Table C405.5.2(1)jurisdiction. <br /> Zone selection required to enable LTG-EXT form <br /> Specified by jurisdiction. <br /> Calculation Area Q 0 Addition- Q Addition <br /> stand alone +existing <br /> Q Alteration with<50% Q Alteration with>_50%ext. <br /> ext.wattage replaced wattage replaced <br /> Building Grounds 0 Efficacy>80 lumens/watt ❑Exemption <br /> Applies to luminaires> <br /> 100 Watts r--1 <br /> Controlled by motion sensor <br /> Tradable Maximum Allowed Lighting Wattage NOTE' <br /> g g g Base Site Allowance: 1300 <br /> Area(ft`),perimeter(If) Allowed Watts Allowed Watts <br /> Tradable Surfaces Surface Description or#of items per ft2 or per If x ft2(or x If) <br /> Uncovered Parking and drives Asphalt,concrete 15300 0.10 W/ft2 1530 <br /> Grounds Walkways <10 wide Concrete 247 1.0 W/LF 247 <br /> Main Entry Door Metal/Glass 3 30W/LF door 90 <br /> Entry Canopies Concrete 905 0.4 W/ft2 362 <br /> Total Allowed Tradable+Site Allowance Watts: 3529 <br /> Tradable Proposed Lighting Wattage NOTE 2 <br /> Number of Watts per Watts <br /> Tradable Surface Fixture Description NOTE a,a Fixtures Fixture NOTE 5 Proposed <br /> Uncovered Parking and drives Existing pole mounted luminaire 3 100 300 <br /> Grounds Walkways <10 wide Pole mounted Lumnaire to match parking 1 100 100 <br /> Main Entry Door Recessed downlight,LED,1 bulb 2 9 18 <br /> Entry Canopies Recessed downlight,LED,1 bulb 18 9 162 <br /> Entry Canopies Canopy Rope Light,LED 6 13 78 <br /> Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: 658 <br /> watts plus the base site allowance. Any base site allowance not needed to make <br /> tradable watts comply can be applied to individual non-tradable categories. <br /> Non-Tradable Maximum Allowed Lighting Wattage""'t' <br /> g g g Site Allowance Remaining: 1300 <br /> • Area(ft2),perimeter(If) Allowed Watts Allowed Watts <br /> Non-Tradable Surfaces Surface Description or#of items per ft2 or per If x ft2(or x If) <br /> Bldg.Façade Metal sidng plank,metal siding panel,concrete 4410 0.2 W/ft2 882 <br /> Non-Tradable Proposed Lighting Wattage NOTE 2 <br /> Number of Watts per Watts <br /> Non Tradable Surface Fixture Description NOTE s,a Fixtures Fixture NOTE 5 Proposed <br /> Bldg.Façade Wall Sconce,LED,1 lamp 5 15 75 <br /> Non-tradable proposed watts may not exceed allowed watts for any individual Non-Tradable Watts Exceeding LPA: 0 <br /> surface unless the total excess watts for all non-tradable surfaces are less than the <br /> remaining site allowance. Remaining Site Allowance: 1300 <br /> Exterior Lighting COMPLIES WITH MAX. ALLOWANCE <br /> Note 1-List all unique exterior sufaces per Table C405.5.2(2)that occur in the project scope.Select exterior surface categories from drop <br /> down menu. <br /> Note 2-List all proposed lighting fixtures including existing-to-remain fixtures. <br /> Note 3-For proposed Fixture Description,indicate fixture type,lamp type,number of lamps in the fixture,and ballast type(if applicable). <br /> Note 4-Existing-to-remain fixtures shall be included in the Tradable and Non-Tradable Proposed Lighting Wattage tables in the same manner <br /> as new fixtures.identify as existing in fixture description. <br /> Note 5-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br />