My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
>
Address Records
>
EVERGREEN WAY
>
6502
>
ENHANCED SERVICE FACILITIES
>
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2020 9:13:55 AM
Creation date
5/29/2019 3:24:21 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6502
Tenant Name
ENHANCED SERVICE FACILITIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
541
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Exterior Lighting LTG-EXT <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Enhanced Services Facilities(ESF)+Retail Date 10/13/2017 <br /> Exterior Li htin For Building Department Use <br /> g g Q Zone 1 Q Zone 2 Q Zone 3 Q Zone 4 <br /> Zone Table C405.5.2(1)jurisdiction. <br /> Zone selection required to enable LTG-EXT form <br /> Specified by jurisdiction. <br /> Calculation Area Q 0 Addition- Q Addition <br /> stand alone +existing <br /> Q Alteration with<50% Q Alteration with>_50%ext. <br /> ext.wattage replaced wattage replaced <br /> Building Grounds 0 Efficacy>80 lumens/watt ❑Exemption <br /> Applies to luminaires> <br /> 100 Watts r--1 <br /> Controlled by motion sensor <br /> Tradable Maximum Allowed Lighting Wattage NOTE' <br /> g g g Base Site Allowance: 1300 <br /> Area(ft`),perimeter(If) Allowed Watts Allowed Watts <br /> Tradable Surfaces Surface Description or#of items per ft2 or per If x ft2(or x If) <br /> Uncovered Parking and drives Asphalt,concrete 15300 0.10 W/ft2 1530 <br /> Grounds Walkways <10 wide Concrete 247 1.0 W/LF 247 <br /> Main Entry Door Metal/Glass 3 30W/LF door 90 <br /> Entry Canopies Concrete 905 0.4 W/ft2 362 <br /> Total Allowed Tradable+Site Allowance Watts: 3529 <br /> Tradable Proposed Lighting Wattage NOTE 2 <br /> Number of Watts per Watts <br /> Tradable Surface Fixture Description NOTE a,a Fixtures Fixture NOTE 5 Proposed <br /> Uncovered Parking and drives Existing pole mounted luminaire 3 100 300 <br /> Grounds Walkways <10 wide Pole mounted Lumnaire to match parking 1 100 100 <br /> Main Entry Door Recessed downlight,LED,1 bulb 2 9 18 <br /> Entry Canopies Recessed downlight,LED,1 bulb 18 9 162 <br /> Entry Canopies Canopy Rope Light,LED 6 13 78 <br /> Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: 658 <br /> watts plus the base site allowance. Any base site allowance not needed to make <br /> tradable watts comply can be applied to individual non-tradable categories. <br /> Non-Tradable Maximum Allowed Lighting Wattage""'t' <br /> g g g Site Allowance Remaining: 1300 <br /> • Area(ft2),perimeter(If) Allowed Watts Allowed Watts <br /> Non-Tradable Surfaces Surface Description or#of items per ft2 or per If x ft2(or x If) <br /> Bldg.Façade Metal sidng plank,metal siding panel,concrete 4410 0.2 W/ft2 882 <br /> Non-Tradable Proposed Lighting Wattage NOTE 2 <br /> Number of Watts per Watts <br /> Non Tradable Surface Fixture Description NOTE s,a Fixtures Fixture NOTE 5 Proposed <br /> Bldg.Façade Wall Sconce,LED,1 lamp 5 15 75 <br /> Non-tradable proposed watts may not exceed allowed watts for any individual Non-Tradable Watts Exceeding LPA: 0 <br /> surface unless the total excess watts for all non-tradable surfaces are less than the <br /> remaining site allowance. Remaining Site Allowance: 1300 <br /> Exterior Lighting COMPLIES WITH MAX. ALLOWANCE <br /> Note 1-List all unique exterior sufaces per Table C405.5.2(2)that occur in the project scope.Select exterior surface categories from drop <br /> down menu. <br /> Note 2-List all proposed lighting fixtures including existing-to-remain fixtures. <br /> Note 3-For proposed Fixture Description,indicate fixture type,lamp type,number of lamps in the fixture,and ballast type(if applicable). <br /> Note 4-Existing-to-remain fixtures shall be included in the Tradable and Non-Tradable Proposed Lighting Wattage tables in the same manner <br /> as new fixtures.identify as existing in fixture description. <br /> Note 5-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br />
The URL can be used to link to this page
Your browser does not support the video tag.