Lighting, Motor, and Electrical Permit Checklist, Pg. 1 LTG-CHK
<br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016
<br /> Project Title: Enhanced Services Facilities(ESF)+Retail Date 10/13/2017
<br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the
<br /> Washington State Energy Code,Commercial Provisions.
<br /> Applicability Location in Building Department
<br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes
<br /> LIGHTING CONTROLS
<br /> Yes C405.2 Lighting controls, For all lighting fixtures,indicate lighting control method on plans E211,E213,E214
<br /> general for spaces and lighting zone(s)served,or exception taken
<br /> Luminaire level Indicate on plans all fixtures provided with LLLC in lieu of
<br /> NA C405.2 lighting controls C405.2 lighting controls;provide description of control
<br /> (LLLC) capabilities and performance parameters
<br /> For permanently installed lighting fixtures in dwelling units,
<br /> Yes C405.1 Lighting in dwelling indicate lighting control method on plans for spaces and E213,E214,E301
<br /> units lighting zone(s)served,or demonstrate compliance with high
<br /> efficacy exception
<br /> C405.2.3 Indicate on plans the method of manual lighting control(whether
<br /> C405.2.1.1 combined with occupancy sensor,automatic light reduction,
<br /> Yes C405.2.2.2 Manual controls daylight responsive or specific application controls),location of E211,E213,E214
<br /> C405.2.4 manual control device and area or specifice application it
<br /> C405.2.5 serves
<br /> C405.2.2.1 Manual interior Indicate on plans which method of manual 50%lighting load
<br /> Yes C405.2.2.2 reduction is provided,or whether lighting load is reduced via E211,E213,E214
<br /> C405.2.3 lighting controls occupancy sensors or daylight responsive controls
<br /> Indicate on plans the method of automatic shut-off control
<br /> during unoccupied periods(occupancy sensor or time switch) E211,E213,E214
<br /> Yes C405.2.2 Method of automatic for all lighting zones;
<br /> shut-off control Indicate locations where automatic shutoff is provided by other
<br /> methods(occupancy sensor or digital timer switch)or which E211,E213,E214
<br /> time switch control exception applies
<br /> Indicate on plans the spaces served by occupancy sensors; E211,E213,E214
<br /> Yes C405.2.1 Occupancy sensor Indicate whether occupancy sensor controls are configured to
<br /> C405.2.1.1 controls be manual-on,automatic 50%-on,or serve a space eligible for E211,E213,E214
<br /> automatic 100%-on per exception
<br /> Occupancy sensor Indicate aisleways and open areas in warehouse spaces
<br /> NA C405.2.1.2 controls- provided with occupancy sensor controls that reduce lighting
<br /> warehouses power by 50%
<br /> NA C405.2.6 Digital timer switch Indicate required digital timer switch control function when
<br /> control is used
<br /> NA C405.2.2.1 Automatic time Indicate locations of override switches on plans and the lighting
<br /> switch controls zone(s)served,include area sq.ft.
<br /> Indicate primary and secondary sidelight daylight zone areas on E211,E213,E214
<br /> plans,include sq.ft.;
<br /> C405.2.4.2 Daylight zones- Indicate toplight daylight zone areas on plans,include sq.ft.;
<br /> YesFor small vertical fenestration assemblies(rough opening less
<br /> C405.2.4.3 Sidelight and toplight ( 9 P 9
<br /> than 10 percent of primary daylight zone)where daylight
<br /> responsive controls are not required,provide fenestration area
<br /> to daylight zone calculation(s)
<br /> Indicate on plans lighting zone(s)served by daylight responsive E211,E213,E214
<br /> controls;
<br /> Identify sidelight and toplight daylight zones that are not
<br /> provided with daylight sensing controls and the exception(s)that NA
<br /> Yes C405.2.4 Daylight responsive apply;
<br /> controls Indicate on plans the lighting load reduction method-
<br /> continuous dimming,or stepped dimming that provides at least E301
<br /> two even steps between 0%-100%of rated power;
<br /> Indicate that daylight sensing controls are configured to E301
<br /> completely shut off all controlled lights in the lighting zone
<br /> Additional controls Identify spaces and lighting fixtures on plans that require
<br /> NA C405.2.5 Specific application
<br /> lighting controls specific application lighting controls per this section
<br /> Indicate on plans that display and accent lighting,and display
<br /> C405.2.5- Display and accent case lighting are controlled independently from both general
<br /> NAarea lighting and other lighting applications within the same
<br /> Items 1&2 lighting
<br /> space;
<br /> Indicate manual and automatic lighting control method