My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
>
Address Records
>
EVERGREEN WAY
>
6502
>
ENHANCED SERVICE FACILITIES
>
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2020 9:13:55 AM
Creation date
5/29/2019 3:24:21 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6502
Tenant Name
ENHANCED SERVICE FACILITIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
541
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Enhanced Services Facilities(ESF)+Retail Date 10/13/2017 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> C405.2.5- Hotel/motel guest Indicate method of automatic control-vacancy or captive key <br /> NAcontrol of all installed luminaires and switched receptacles in <br /> Item 3 rooms guest room <br /> C405.2.5- Supplemental task Indicate method and location of automatic shut-off vacancy <br /> Yes control for supplemental task lighting,including under-shelf or E213 <br /> Item 4 lighting under-cabinet lighting <br /> Indicate on plans eligible non-visual lighting applications, <br /> include sq.ft.area of each lighting control zone; <br /> C405.2.5- Lighting for non- Indicate on plans that non-visual lighting are controlled <br /> NAindependently from both general area lighting and other lighting <br /> Item 5 visual applications <br /> applications within the same space; <br /> Indicate method of manual lighting control and applicable <br /> automatic lighting control <br /> Indicate on plans that lighting equipment for sale or <br /> Lighting equipment demonstration are controlled independently from both general <br /> NA C405.2.5- for sale or area lighting and other lighting applications within the same <br /> Item 6 demonstration space; <br /> Indicate method of manual lighting control and applicable <br /> automatic lighting control <br /> Identify on plans egress fixtures that function as both normal E211,E213,E214 <br /> and emergency means of egress illumination; <br /> Provide calculation of lighting power density of total egress <br /> Yes C405.2.5- Means of egress lighting; <br /> Item 7 lighting If total egress lighting power density is greater than 0.02 W/sq. <br /> ft.,indicate on plans egress fixtures requiring automatic shut-off <br /> during unoccupied periods; <br /> Indicate method of automatic shut-off control <br /> Indicate on exterior lighting plans and fixture schedules the <br /> automatic lighting control method,control sequence,and E101 <br /> locations served; <br /> For building façade and landscape lighting,indicate automatic <br /> Exterior lighting controls shut off lighting as a function of dawn/dusk and fixed E101 <br /> Yes C405.2.7 opening/closing time; <br /> controls <br /> For all other exierior lighting,indicate automatic controls shut off <br /> lighting as a function of available daylight;include control <br /> sequence that also reduces lighting power by at least 30% E101 <br /> between 12am-6am,or from 1 hour after closing to 1 hour <br /> before opening,or based upon motion sensor <br /> Exterior building For building grounds fixtures greater than 100 watts,indicate on <br /> NA C405.5.1 grounds lighting plans whether fixtures have efficacy greater than 80 lumens or; <br /> controls are controlled by motion sensor,or are exempt lighting per <br /> C405.5.2 <br /> Area controls- Indicate location(s)of master control switch(es)intended to <br /> Master control control multiple independent switches;circuit breaker may not <br /> NA C405.2.5 be used as a master control switch; <br /> switches and circuit <br /> power limit Verify that no 20 amp circuit controlled by a single switch or <br /> automatic control is loaded beyond 80% <br /> To comply with additional efficiency package option,indicate on <br /> plans all interior lighting fixtures that are individually addressed <br /> and provided with continuous dimming,or exception taken; <br /> NA C406.4 Enhanced digital <br /> lighting controls Include calculation of percent total installed interior lighting <br /> power that is configured with required enhanced lighting control <br /> functions(min 90%to comply with additional efficiency package <br /> option) <br /> If claiming lighting system commissioning exemption provide E501,E502 <br /> supporting calculation; <br /> C405.13 Lighting system Identify applicable commissioning documentation requirements 408.3 Ex.1&2 <br /> No C408.3 functional testing per Section C408 or eligibility for exception; <br /> Provide written procedures for functional testing of all automatic <br /> controls and describe the expected system response <br />
The URL can be used to link to this page
Your browser does not support the video tag.