My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
>
Address Records
>
EVERGREEN WAY
>
6502
>
ENHANCED SERVICE FACILITIES
>
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2020 9:13:55 AM
Creation date
5/29/2019 3:24:21 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6502
Tenant Name
ENHANCED SERVICE FACILITIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
541
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 2 of 6 <br /> c. Sheet C-2: See redlines. Update TESC Legend and adjust line work to correctly <br /> show TESC elements and remove site improvements from this sheet. <br /> Legend update and redlines addressed. <br /> d. Sheet C-3: Update City of Everett Standards to match current names and <br /> standard drawing numbers in the DCSS. See redlines. <br /> Standard drawings updated and redlines addressed. <br /> e. Sheet C-4: See redlined notes regarding re-use of existing 3/4" water meter. <br /> Water meter will not be reused. New domestic line is being proposed from Fleming. <br /> f, Sheet C-5: See redlines. A fire hydrant, FDC, and PIV need to be added to the <br /> plans on the Fleming Street side of the project, On the Evergreen Way side of the <br /> project, the domestic water service needs to be sized adequately for the demand of <br /> the proposed project. The existing %" service can be reused for irrigation only, with <br /> the addition of a DCV A behind the meter. The domestic water service should be <br /> larger (your engineers to determine what size). The City will make the connection <br /> to the main. Please add these notes to the plans. An RPBA is required behind the <br /> domestic meter and shall be located in a hot box since the service line is greater <br /> than 70' long. <br /> Hydrant is added along Fleming. FDC is located in the island by the garage <br /> entrance, Ply is located in the west courtyard area. The ex, meter will not be <br /> used. <br /> g. Sheet C-7: Call out and label curbing wherever planned, At the end points it is <br /> best to call out BC and TC elevations. The contour lines drawn do not match typical <br /> grading associated with curbs based on how the contours travel over the curbs. In <br /> some cases, particularly near the ramp into the parking garage, the contour lines <br /> travel over the curb in opposite directions. This grading error has made a 1' <br /> elevation error on the parking garage ramp and needs to be corrected. I would <br /> suggest starting at the grade needed to meet parking garage finish floor elevation <br /> and grading out from there. This could in turn affect the conveyance system on- <br /> site, as the rim elevations may need to change and that may affect the inverts if <br /> the required rim to invert distance is not met due to surface grading revisions. <br /> Please carefully update this entire system and a complete review will be conducted <br /> upon resubmittal. <br /> Grading has been updated and more detail called out along the curbs/walls and <br /> road/driveways. There was not a 1'error on the grading of the ramp and the new <br /> callouts for the walls should make it clearer what is being proposed in the ramp <br /> area. <br /> h. Sheet C-8: The profile shows utility crossings for power and the roofleader. <br /> Please callout the clearances between these utilities and the storm conveyance <br /> system. The required vertical and horizontal clearances must be met for these <br /> utilities. <br /> Clearances added to the profile <br /> i. Sheet C-9: See all redlines. The contours on the frontage improvement need to <br /> be revised to ensure a cross slope no greater than 2% to meet ADA requirements. <br /> The existing (surveyed) spot elevations or contours should be shown to ensure that <br /> the curb height is adequate and aligns with the sidewalk grading design. Please <br /> remove the truncated domes shown on either side of the driveway and correctly <br /> show the driveway on the plans to meet the details of Standard Detail #315. Spot <br /> grades should be added to the driveway to ensure constructability as designed and <br /> that grading aligns with designed ramp grades. There was a previous issue with the <br /> frontage improvements due to existing locations of poles and other equipment. How <br /> P:\2016\16153 ESF&Retail everett\P& \Text\Correspondence\Everett 1st review.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.