My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
>
Address Records
>
EVERGREEN WAY
>
6502
>
ENHANCED SERVICE FACILITIES
>
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2020 9:13:55 AM
Creation date
5/29/2019 3:24:21 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6502
Tenant Name
ENHANCED SERVICE FACILITIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
541
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBLIC WORKS' <br /> 26 August 2017 <br /> Owner: Todd Madison, toddmadison@hotmail.com <br /> Madison Real Property LLC <br /> Job Address: 6502 Evergreen Way <br /> Plan Check No: B1705-014 <br /> RE: Corrections Letter <br /> Dear Mr. Madison, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two new sets of revised construction documents reflecting the corrections <br /> requested. Please include a response letter which indicates how the corrections were resolved. <br /> Non Structural Comments only, Structural comments previously sent <br /> General <br /> 1. The plans should note whether this is a two story building or one story with a <br /> basement. Section 504.4 <br /> 2. The distance of the building to the southern property line is difficult to scale on the <br /> 1/16" plan but appears to be less than five feet at some places. Please display the <br /> distances and the percentage of unprotected openings within the southern exterior <br /> walls. Table 708.5 <br /> a. If the southern exterior wall is less than 5' to the property line, the southern <br /> exterior walls (upper floor) should be shown to continue through the roof trusses <br /> to the underside of the roof-sheathing (fire-resistive construction on both sides <br /> of the wall). Exception 4 to Section 705.11 <br /> 3. Walls that are required to be of fire-resistive construction should be shown on the floor <br /> plans (the wall tags on the building sections are difficult to follow). Section 107.2.1 <br /> 4. The floor plans should show (building sections are not clear enough) that the walls <br /> between adjacent sleeping units and between each sleeping unit and adjacent spaces <br /> have a minimum sound transmission class of not less than 50. Section 1207.2 <br /> 5. Door 027A from the garage to the future tenant space is through a one-hour occupancy <br /> separation wall. The door should be shown as a minimum 45-minute rated assembly. <br /> Section 707.3.9 and Table 716.5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.