My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
>
Address Records
>
EVERGREEN WAY
>
6502
>
ENHANCED SERVICE FACILITIES
>
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2020 9:13:55 AM
Creation date
5/29/2019 3:24:21 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6502
Tenant Name
ENHANCED SERVICE FACILITIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
541
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. There is a one-hour wall notation on Sheet A005 on the ground floor surrounding the <br /> stairs and elevator area. If this is the one-hour occupancy separation between the S-2 <br /> and I-1 occupancy above than door 024B and adjacent sidelite should be shown as <br /> minimum 45-minute rated assemblies. More simply, the stairway enclosure itself (on the <br /> lower floor) could be the occupancy separation — the diagram on sheet A005 would just <br /> need to be revised. <br /> 7. One-hour, fire-resistive roof/ceiling assembly detail R1/A601 depicts TJI's however the <br /> project uses trusses and 2x12's. Fire-resistive assemblies using wood-trusses and 2x12's <br /> should be provided. Section 703.2 <br /> 8. The roof/ceiling assembly over the exterior deck (room 117) and western patio should <br /> be shown as minimum one-hour fire-resistive construction as those useable areas under <br /> the projected roof constitute building area. Section 602.1 <br /> 9. The following comments apply to the shafts on the second floor: <br /> a. Fire dampers should be provided at the duct penetrations of the concrete floor <br /> (Section 1717.6.1), or <br /> i. The shafts should be shown as minimum one-hour fire resistive <br /> construction to maintain the one-hour occupancy separation between the <br /> occupancies on each floor (Sections 508.4.4 and 717.6) and, <br /> ii. The shafts should be shown to continue to the underside of the roof <br /> sheathing (Section 707.5). <br /> 10.The following comments apply to air ducts penetrating the fire-resistive ceiling <br /> membrane of the second floor roof/ceiling assembly in accordance with Section 717.6.2: <br /> a. Air ducts that penetrate the ceiling should be shown with ceiling radiation <br /> dampers. <br /> b. Exhaust ducts serving the dryers within the laundry room will be required to be <br /> within a rated shaft through the attic. The shaft construction should be detailed <br /> on the plans. <br /> c. Any duct serving the kitchen hood (residential, type II or type I) should be <br /> provided with a shaft. <br /> 11.The upstairs kitchen has a commercial cooking appliance shown (American Range <br /> AR12G-6B). The manufacturer's specification indicates this equipment is a Heavy Duty <br /> Restaurant Range. IMC Section 507.2 requires a Type I hood for this application. <br /> Clearance to combustibles is also required by Section 507.2.6 which may necessitate the <br /> revision of wood framing to non-combustible framing. <br /> a. Note: we have correspondence forwarded from DOH that there is a state <br /> amendment to the IMC regarding this. The amendment and section were not <br /> provided. Assuming this is the amendment to Section 507.2 Exception 2 we will <br /> need further verification that there is a state interpretation affirming that an I-1 <br /> Condition 2 Occupancy is a 'R-2 type Occupancy' in this instance. <br /> 12.The proposed dishwashers (Fagor CO-502W) are high-temperature, commercial <br /> dishwashers. Type II hoods are required per Section 507.3 <br /> Egress <br /> 7 <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8813 • Page 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.