My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
>
Address Records
>
EVERGREEN WAY
>
6502
>
ENHANCED SERVICE FACILITIES
>
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2020 9:13:55 AM
Creation date
5/29/2019 3:24:21 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6502
Tenant Name
ENHANCED SERVICE FACILITIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
541
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONsI:;1,I1NG F N G IN!'?A R <br /> October 13,2017 <br /> Mr.James Bronder <br /> City of Everett,Everett,WA. <br /> Sub: Response to Structural Review by James Bronder: 6504 Evergreen Way,WA 98203 <br /> 1 Dear Mr.James Bronder: <br /> We are writing this in response to the structural review comments made by you in a document dated 08/10/2017. <br /> Our response is in Times New Roman font style under each comment: <br /> PSM Response to Reviewed Comments in Structural Package <br /> Comment#1: On Detail B/S304, it appears that temporary shoring is being provided by others. Please <br /> provide drawings indicating the extents of shoring and what the shoring system being used on the <br /> project. <br /> RESPONSE: Please review updated section submitted in latest drawing set. There is no requirement of <br /> shoring anymore based on current design revision. <br /> Comment#2: On several foundation details (for example, B/S304), it appears that the slab-on-grade is <br /> tying into the concrete basement and shear walls. Please provide clarification regarding this detailing <br /> condition. <br /> RESPONSE: Wall is tied at top to PT deck and at bottom to SOG. The wall has been designed as <br /> restrained retaining wall for soil loads:And dowels connecting wall to SOG/PT deck have been spaced <br /> based on design force requirement of in-plane seismic shear and out of plane sliding restrain for <br /> restrained retaining shearwall. <br /> Comment#3: On General Structural Notes, it appears that the seismic coefficient for the concrete shear <br /> wall portion of the lateral force resisting system is less than the wood shear wall portion. Please clarify <br /> and revise as required. <br /> RESPONSE: General Notes and Special Inspection Notes sheets of the project have been completely <br /> revised to incorporate all needed revisions. <br /> Comment#4: It appears that the site and proposed structure has an unbalanced soil loading condition <br /> that has not been accounted for in the structure in the east-west direction of loading. Please revise base <br /> shear values and shear wall design as required. <br /> RESPONSE: We have updated calculations to this effect. Please see Etabs report section of calculation <br /> package (on page#98) for loading condition described above. <br /> Comment#5: Please verify column vertical reinforcement, vertical reinforcement for concrete shear <br /> walls, and weldable reinforcement is ASTM Grade A706 reinforcement per ACI 318-14 Sec. 20.2.2.5. <br /> 2200 6TH AVENUE, ri601. WWW.PSM-ENGINEERS.COM PHONE 206-622-4580 <br /> SEATTLE WASHINGTON 98121 USA FAX 206-622-0422 <br />
The URL can be used to link to this page
Your browser does not support the video tag.