Laserfiche WebLink
L '45I,JG Opp�c& 0111 <br /> chvac-Futt Commercial HVAC Loads Cat.caldLiadon Program Elite Software Development,;lint <br /> �Abossen Engineering <br /> Bellevue,YUA 98004 <br /> Bu din g Si,nma Loads <br /> Building peaks in August at earn: <br /> Bldg Load Area Sen %Tot Lat Sen Net %Net <br /> Descriptions Quart Loss Loss Gain Gain Gain Gain <br /> Roof 0 0 0.00 0 0 0 0.00 <br /> Wall 156 1,168 7.26 0 282 282 0.89 <br /> Glass 329 6,529 40.58 0 22,637 22,637 71.28 <br /> Floor Slab 0 0 0.00 0 0 0 0.00 <br /> Skin Loads 7,697 47.84 0 22,919 22,919 72.17 <br /> Lighting 618 0 <br /> 0.00 0 2,109 2,109 6.64 <br /> Equipment 1,000 0 0.00 0 3,412 3,412 10.74 <br /> People 6 0 0.00 1,200 1,500 2,700 8.50 <br /> Partition 618 941 5.85 0 896 896 2.82 <br /> Cool. Pret. 0 0 0.00 0 0 0 0.00 <br /> Heat. Pret. 0 0 0.00 0 0 0 0.00 <br /> Cool. Vent. 70 0 0.00 437 -754 -316 -1.00 <br /> Heat. Vent. 70 3,995 24.83 0 0 0 0.00 <br /> Cool. Infil. 58 0 0.00 337 -633 -296 -0.93 <br /> Heat. Infil. 58 3,457 21.48 0 0 0 0.00 <br /> Draw-Thru Fan 0 0 0.00 0 333 333 1.05 <br /> Blow-Thru Fan 0 0 0.00 0 0 0 0.00 <br /> Reserve Cap. 0 0 0.00 0 0 0 0.00 <br /> Reheat Cap. 0 0 0.00 0 0 0 0.00 <br /> Supply Duct 0 0 0.00 0 0 0 0.00 <br /> Return Duct 0 0 0.00 0 0 0 0.00 <br /> Misc. Supply 0 0 0.00 0 0 0 0.00 <br /> Misc. Return 0 0 0.00 0 0 0 0.00 <br /> Building Totals 16,089 100.00 1,975 29,781 31,756 100.00 <br /> Building Sen %Tot Lat Sen Net %Net <br /> Summary Loss Loss Gain Gain Gain Gain <br /> Ventilation = 3,995 24.83 437 454 -316 -1.00 <br /> Infiltration 3,457 21.48 337 -633 -296 -0.93 <br /> Pretreated Air 0 0.00 0 0 0 0.00 <br /> Zone Loads 8,637 53.68 1,200 30,836 32,036 100.88 <br /> Plenum Loads 0 0.00 0 0 0 0.00 <br /> Fan/Duct/Misc Loads 0 0.00 0 333 333 1.05 <br /> Building Totals 16,089 100.00 1,975 29,781 31,756 100.00 <br /> Check Figures <br /> Total Building Supply Air(based on a 20"TD): 1,418 CFM <br /> Total Building Vent.Air(4.94%of Supply): 70 CFM <br /> Total Conditioned Air Space: 618 Sq.ft <br /> Supply Air Per Unit Area: 2.2948 CFM/Sq.ft <br /> Area Per Cooling Capacity: 233.5 Sq.ft/Ton <br /> Cooling Capacity Per Area: 0.0043 Tons/Sq.ft <br /> Heating Capacity Per Area: 26.03 Btuh/Sq.ft <br /> Total Heating Required With Outside Air: 16,089 Btuh <br /> Total Cooling Required With Outside Air: 2.65 Tons <br /> 9//2 <br /> J:\212158\Calc-Mech\Heat Loss&Gain Calcs\Leasing Office 014.CHV Friday,May 17,2013,07:22 PM <br />