Laserfiche WebLink
L088Y 020 <br /> Chvac-Full Commercial HVAC Loads Ca cu ation Program Elite Software Development,Inc. <br /> Abossen Engineering ff <br /> Bellevue,WA 98004- 6,1 .. -P-0 <br /> Bu ldin . Summa Loads <br /> Building peaks in August at 9am. <br /> Bldg Load Area Sen %Tot Let Sen Net %Net <br /> Descriptions Quan Loss Loss Gain Gain Gain Gain <br /> Roof ... 0 0 0.00 0 0 0 0.00 <br /> Wall 1,607 3,429 10.08 0 -198 -198 -0.39 <br /> Glass 583 11,570 34.01 0 36,903 36,903 73.06 <br /> Floor Slab 0 0 0.00 0 0 0 0.00 <br /> Skin Loads 14,998 44.09 0 36,705 36,705 72.67 <br /> Lighting 1,461 0 0.00 0 4,985 4,985 9.87 <br /> Equipment 0 0 0.00 0 0 0 0.00 <br /> People 22 0 0.00 4,400 5,500 9,900 19.60 <br /> Partition 0 0 0.00 0 0 0 0.00 <br /> Cool. Pret. 0 0 0.00 0 0 0 0.00 <br /> Heat. Pret. 0 0 0.00 0 0 0 0.00 <br /> Cool. Vent. 190 0 0.00 1,187 -2,045 -858 -1.70 <br /> Heat. Vent. 190 10,844 31.88 0 0 0 0.00 <br /> Cool. Infil. 136 0 0.00 798 -1,497 -700 -1.38 <br /> Heat. !nth. 136 8,172 24.02 0 0 0 0.00 <br /> Draw-Thru Fan 0 0 0.00 0 479 479 0.95 <br /> Blow-Thru Fan 0 0 0.00 0 0 0 0.00 <br /> Reserve Cap. 0 0 0.00 0 0 0 0.00 <br /> Reheat Cap. 0 0 0.00 0 0 0 0.00 <br /> Supply Duct 0 0 0.00 0 0 0 0.00 <br /> Return Duct 0 0 0.00 0 0 0 0.00 <br /> Misc. Supply 0 0 0.00 0 0 0 0.00 <br /> Misc. Return 0 0 0.00 0 0 0 0.00 <br /> Building Totals 34,015 100.00 6,385 44,126 50,511 100.00 <br /> Building Sen %Tot Lat Sen " Net %Net ' <br /> Summary Loss Loss Gain Gain Gain Gain <br /> Ventilation 10,844 31.88 1,187 -2,045 -858 -1.70 <br /> Infiltration 8,172 24.02 798 -1,497 -700 -1.38 <br /> Pretreated Air 0 0.00 0 0 0 0.00 <br /> Zone Loads 14,998 44.09 4,400 47,190 51,590 102.14 <br /> Plenum Loads 0 0.00 0 0 0 0.00 <br /> Fan/Duct/Misc Loads 0 0.00 0 479 479 0.95 <br /> Building Totals 34,015 100.00 6,385 44,126 50,511 100.00 <br /> Check Fi o tares <br /> Total Building Supply Air(based on a 21°TD): 2,042 CFM <br /> Total Building Vent.Air(9.30%of Supply): 190 CFM <br /> Total Conditioned Air Space: 1,461 Sq.ft <br /> Supply Air Per Unit Area: 1.3979 CFM/Sq.ft <br /> Area Per Cooling Capacity: 347.1 Sq.ft/Ton <br /> Cooling Capacity Per Area: 0.0029 Tons/Sq.ft <br /> Heating Capacity Per Area: 23.28 Btuh/Sq.ft <br /> Total Heating Required With Outside Air: 34,015 Btuh <br /> Total Cooling Required With Outside Air: 4.21 Tons <br /> 3 <br /> J:\212158\Calc-Mech\Heat Loss&Gain Calcs\Residential Lobby 020.CHV Friday,May 17,2013,07:23 PM <br />