My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
>
Address Records
>
GRAND AVE
>
2900
>
PAGODA VILLAGE
>
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2025 8:56:50 AM
Creation date
5/30/2019 7:21:35 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2900
Tenant Name
PAGODA VILLAGE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
515
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BUSINESS CeWTEr2 2 <br /> Chvgc-Full Commercial.HVAC Loads Calcu a ion Program Elite Software Development,;inc. <br /> tbossen Engineering l <br /> ' <br /> Bellevue WA 98004 ' a <br /> v ;� <br /> Building Summary Loads <br /> Building peaks in August at 3pm. <br /> Bldg Load Area Sen ,e '� Lat . .... Sen Net %Net' <br /> Desc on Quan' Loss Loss Gain Gain Gain Gain <br /> Roof .,, 0 0 ... 0,00 0 0 0 0:Q0 <br /> Wall 0 0 0.00 0 0 0 0.00 <br /> Glass 0 0 0.00 0 0 0 0.00 <br /> Floor Slab 0 0 0.00 0 0 0 0.00 <br /> Skin Loads 0 0.00 0 0 0 0.00 <br /> Lighting 146 0 0.00 0 498 498 9.72 <br /> Equipment 500 0 0.00 0 1,706 1,706 33.27 <br /> People 6 0 0.00 1,200 1,500 2,700 52.66 <br /> Partition 0 0 0.00 0 0 0 0.00 <br /> Cool. Pret. 0 0 0.00 0 0 0 0.00 <br /> Heat. Pret. 0 0 0.00 0 0 0 0.00 <br /> Cool. Vent. 30 0 0.00 19 129 148 2.89 <br /> Heat. Vent. 30 1,712 77.04 0 0 0 0.00 <br /> Cool. Infil. 9 0 0.00 5 37 42 0.82 <br /> Heat. Infil. 9 510 22.96 0 0 0 0.00 <br /> Draw-Thru Fan 0 0 0.00 0 33 33 0.64 <br /> Blow-Thru Fan 0 0 0.00 0 0 0 0.00 <br /> Reserve Cap. 0 0 0.00 0 0 0 0.00 <br /> Reheat Cap. 0 0 0.00 0 0 0 0.00 <br /> Supply Duct 0 0 0.00 0 0 0 0.00 <br /> Return Duct 0 0 0.00 0 0 0 0.00 <br /> Misc. Supply 0 0 0.00 0 0 0 0.00 <br /> Misc. Return 0 0 0.00 0 0 0 0.00 <br /> Building Totals 2,223 100.00 1,224 3,903 5,127 100.00 <br /> Building Sen %Tot Lat Sen Net %Net <br /> Summar Loss Loss Gain . Gain Gain Gain <br /> Ventilation 1,712 77.04 19 " 129 148 2.89 <br /> Infiltration 510 22.96 5 37 42 .0.82 <br /> Pretreated Air 0 0.00 0 0 0 0.00 <br /> Zone Loads 0 0.00 1,200 3,704 4,904 95.65 <br /> Plenum Loads 0 0.00 0 0 0 0.00 <br /> Fan/Duct/Misc Loads 0 0.00 0 33 33 0.64 <br /> Building Totals 2,223 100.00 1,224 3,903 5,127 100.00 <br /> Check Figures <br /> Total Building Supply Air(based on a 25° TD): 140 CFM <br /> Total Building Vent. Air(21.40%of Supply): 30 CFM <br /> Total Conditioned Air Space: 146 Sq.ft <br /> Supply Air Per Unit Area: 0.9604 CFM/Sq.ft <br /> Area Per Cooling Capacity: 341.7 Sq.ft/Ton <br /> Cooling Capacity Per Area: 0.0029 Tons/Sq.ft <br /> Heating Capacity Per Area: 15.22 Btuh/Sq.ft <br /> Total Heating Required With Outside Air: 2,223 Btuh <br /> Total Cooling Required With Outside Air: 0.43 Tons <br /> 7 <br /> J:\212158\Calc-Mech\Heat Loss&Gain Calcs\Business Center 249.CHV Friday,May 17,2013,07:20 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.