My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
>
Address Records
>
GRAND AVE
>
2900
>
PAGODA VILLAGE
>
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2025 8:56:50 AM
Creation date
5/30/2019 7:21:35 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2900
Tenant Name
PAGODA VILLAGE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
515
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ColsiFeeePicE IZM 2Ll ''! <br /> . <br /> _ null <br /> Cbvac-Pali Commercial HVAC Loads Ca Pl'!+I on Program Elite Software Development,Inc. <br /> Abossen Engineering 1 i <br /> tiellevue,WA 98004 , <br /> - ......_ .. .........[ _.. ......_..w ,Building Summary Loads ._ <br /> Building peaks in August at 3pin. <br /> Bldg Load Area Sen %Tot Lat Sen Net Yo Net <br /> Descriptions Quan Loss Loss Gain Gain Gain Gain <br /> Roof 0 0 0,00 0 0 0 0,00 <br /> Wall 0 0 0.00 0 0 0 0.00 <br /> Glass 0 0 0.00 0 0 0 0.00 <br /> Floor Slab 0 0 0.00 0 0 0 0.00 <br /> Skin Loads 0 0.00 0 0 0 0.00 <br /> Lighting 316 0 0.00 0 1,078 1,078 13.89 <br /> Equipment 500 0 0.00 0 1,706 1,706 21.97 <br /> People 10 0 0.00 2,000 2,500 4,500 57.95 <br /> Partition 0 0 0.00 0 0 0 0.00 <br /> Cool. Pret. 0 0 0.00 0 0 0 0.00 <br /> Heat. Pret. 0 0 0.00 0 0 0 0.00 <br /> Cool.Vent. 70 0 0.00 44 301 346 4.45 <br /> Heat. Vent. 70 3,995 78.34 0 0 0 0.00 <br /> Cool. Infil. 18 0 0.00 12 79 91 1.17 <br /> Heat. Infil. 18 1,105 21.66 0 0 0 0.00 <br /> Draw-Thru Fan 0 0 0.00 0 44 44 0.56 <br /> Blow-Thru Fan 0 0 0.00 0 0 0 0.00 <br /> Reserve Cap. 0 0 0.00 0 0 0 0.00 <br /> Reheat Cap. 0 0 0.00 0 0 0 0.00 <br /> Supply Duct 0 0 0.00 0 0 0 0.00 <br /> Return Duct 0 0 0.00 0 0 0 0.00 <br /> Misc. Supply 0 0 0.00 0 0 0 0.00 <br /> Misc. Return 0 0 0.00 0 0 0 0.00 <br /> Building Totals 5,100 100.00 2,056 5,709 7,765 100.00 <br /> Building Sen %Tot Lat Sen Net %Net . <br /> Summary Loss Loss Gain Gain Gain Gain <br /> Ventilation 3,995 78,34 44 301 346. 4.45 <br /> Infiltration 1,105 21.66 12 79 91 1.17 <br /> Pretreated Air 0 0.00 0 0 0 0.00 <br /> Zone Loads 0 0.00 2,000 5,284 7,284 93.81 <br /> Plenum Loads 0 0.00 0 0 0 0.00 <br /> Fan/Duct/Misc Loads 0 0.00 0 44 44 0.56 <br /> Building Totals 5,100 100.00 2,056 5,709 7,765 100.00 <br /> .. _ <br /> Check Figures <br /> Total Building Supply Air(based on a 276 TD): 186 CFM <br /> Total Building Vent. Air(37.63%of Supply): 70 CFM <br /> Total Conditioned Air Space: 316 Sq.ft <br /> Supply Air Per Unit Area: 0.5887 CFM/Sq.ft <br /> Area Per Cooling Capacity: 488.4 Sq.ft/Ton <br /> Cooling Capacity Per Area: 0.0020 Tons/Sq.ft <br /> Heating Capacity Per Area: 16.14 Btuh/Sq.ft <br /> Total Heating Required With Outside Air: 5,100 Btuh <br /> Total Cooling Required With Outside Air: 0.65 Tons <br /> .---, <br /> ..... <br /> J:1212158\Calc-Mech\Heat Loss&Gain Calcs\Conference Room 248.CHV Friday,May 17,2013,07:20 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.