My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
>
Address Records
>
GRAND AVE
>
2900
>
PAGODA VILLAGE
>
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2025 8:56:50 AM
Creation date
5/30/2019 7:21:35 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2900
Tenant Name
PAGODA VILLAGE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
515
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INCI <br /> Materials Testing Consulting, Inc. A, e, <br /> Ga 4edinical&Jemmying A Coming ioSpecial lnspwinn* 'iINkrinb Testing Fnvirrrnml rna1 Cgrmvbig <br /> �ti•-,- 494 <br /> Eexierirryd t1rtmanre Slmro 1M •�i, <br /> Pagoda Village - 13B148 - Field Report: Other: Report#F61987 <br /> CLIENT Path America Farmers Market,LP DATE 12/10/2014 <br /> PROJECT LOCATION Grand and Wall Street PERMIT# <br /> Everett WA <br /> Inspection Information: <br /> Inspection Date: 12/10/2014 Time Onsite: 14:00 PM Weather Conditions: <br /> Inspection Performed: Other <br /> Comments: <br /> MTC on site as requested to conduct bond/cohesion testing of the sprayed tire-resistive materials applied to the various wide flange beams <br /> between grid lines(C-D,9-12)at the level 2 elevation and the HSS 12x8x5/8 beams at grid lines(D.2,9-10)at the level 2 to roof <br /> elevations. <br /> • -MTC conducted non-destructive testing of the sprayed fire-resistive materials per section 5.5.5.1 of the technical manual 12-A and <br /> ASTM standard E736.Incremental weight was attached slowly to the testing caps that were placed on a previous day to an approximate <br /> rate required to be sustained prior to failing.In an area where the testing weight was applied in excess of the required weight the failure <br /> was observed to only be at the surface and perimeter of the testing cap and not from the interface or steel. <br /> -MTC observed that the sprayed fire-resistive materials were found to achieve the required bond/cohesion per the manufactures product <br /> specifications and IBC chapter 17 section 1705.13.6. <br /> Images: <br /> UPLOADED: 12/12/2014 09:32:00 <br /> REPORTED BY:Michael Currie REVIEWED BY:Raymond McNamara,Project Manager <br /> h'1 rrAn wolf y re woe epee+eei..weide ree*it reeeerwreke r+eire ole r'Mar eels erte e.411'ep*eex wi4 e et eaeNeek1 mem! eke%4e.eeeeee4.404 pplinmmoaf a,.�..n,n../A#Me, <br /> eunearree empertearrnperulee:en44edieferedesra Rynrit,n 1.161 •1111 W ntrIeie Tieclap d ceeeuialn1.Inv. Al1rt re r. 1. <br /> Corpnrale * 777 Chrycler Drive • Harlington, WA 48233 * Phalle 360.73.5_11990 * Pea 360.7d{.i9li11 <br /> SW RsRlon • 211S IJI,Aci Lilo Htvd.. S.V OI}rnpia, 911112 * Phone :4CvvI. 4.9111 * Falk i6[I,71;14.97/9 <br /> NW Region * 895. Dilp tt '3Srvct, Stage 5 • kellinghnm, .1122$ • Phone 3.6(I.(41.4m l - Far 360.447.11111 <br /> Visit aur website: vevva.mtr: inc.net <br />
The URL can be used to link to this page
Your browser does not support the video tag.