Materials Testing & Consulting, Inc. `,, <br /> 1.enrk..„,cal I`Mt e'ri &('i n dCint;*Special inspection•'41ntr riab Tr..tinp•F..nvirtrnmentai C.arrwrltarg ,11 _ <br /> s. <br /> Esi mcrrd,lyoeranv.S <br /> rHnry 15551 i <br /> Pagoda Village - 13B148 - Field Report: Other: Report #F66104 <br /> CLIENT Path America Farmers Market,LP DATE 06/22/2015 <br /> PROJECT LOCATION Grand and Wall Street PERMIT# B1306-035 <br /> Everett WA <br /> Inspection Information: <br /> Inspection Date: 06/22/2015 Time Onsite: 01:11 PM Weather Conditions: 178*F Sunny ' <br /> Inspection Performed: I Other <br /> Comments: <br /> Location:balcony,handrail,and sunscreen connection brackets <br /> MTC was onsite to perform after the fact verification of the through bolts for the brackets that attach the balconies,sunscreens,and <br /> handrail.The building is in the final stages of completion.The majority of the units are completed and cleaned. <br /> The initial inspection of the strap and hardware noted on detail N on S5.03 was completed as stated before on reports dated 6-10-15 and <br /> amended to restate the balcony framing per the detail on S5.03.The framing and straps were inspected on the reports dated 7-18-14, <br /> 7-22-14,8-27-14,8-28-14,and 10-6-14.The straps used were LSTA 24 and or 36 depending on the orientation of the joists.The straps <br /> were inspected during the seismic hardware inspections. <br /> In discussion with the engineer of record,it was questioned if MTC had inspected the through bolts for the connection clips for th bolt on <br /> balconies.MTC had not completed any inspections on the through bolts. i <br /> MTC was onsite today and randomly selected 2 areas on each floor to have the contractor open up the area to verify the bolt up <br /> connections due to the building being nearly completed.MTC visually inspected the through bolt connections in the following units:209. <br /> 205,308,303,417,406,512,and 506.In each room an access hole was cut into the finished drywall to expose the bolting.In each case, <br /> the bolting was found to comply with the details set on the SWS balcony shop drawing provided that was revised on 9-11-14.Details <br /> AA-AA and BB-BB were on Sheet E-one.This inspection was completed to verify the balcony connection clip through bolts only. <br /> Images: <br /> l. <br /> I e ' $ >4 <br /> , 1 1 im)r7�t'IR '% 155 <br /> t t I I r I a i 0r % , <br /> 1 .x. any <br /> Lii <br /> 10:33 06/22/2015 <br /> UPLOADED:06/22/2015 13:56:00 UPLOADED:06/22/2015 13:57:00 <br /> looking at the SE corner of the building overall of the looking at the through bolts installed <br /> balconies <br /> 44 woe*woo R✓<.. ,erl.avt;.wa•t1•rrrrMh q..• M tart•d1•441a104 10clim alisr *14.4 Amelvss.rn•.artear aeFiwl a..,.. /.*2arr.:idie i.rnc i.11w+e01=1*.rt614140.d'+..rlr WIS.r••_ ,,i* <br /> arras from a"wok"ser warts Maafaadrailri au INvent gnr-,4 S 7401 - 7.117 14rrrrl11111 rear log f Cs arid,le•.Iron A11 r, ,,rr s-rrr ri. <br /> Corporate * 777 Chrysler Drive • Burlington, WA. 96233 • Phone 60-755.1990 • Fat 360.7$3.198S <br /> SW R*gion • 111x Black Late Blvd S W • 01)rripia, WA ri$ 12 • Phone .lrrtl.134.977i' • f.ax T0.534.91 <br /> NW Reglan • litl5 Dupont Street, Suit* 5 • ltetlinghnm. W . 04223 • Phone 360.f/41'11tMI • 1r,1- RIO.641.11I I I <br /> Visit aur website: WW1:-M c ine net <br /> Pagoda Village-13B148,06/22/2015,#F66104,Page 1 of 2 <br />