My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3301 SEAWAY BLVD Geotech Report 2022-10-25
>
Address Records
>
SEAWAY BLVD
>
3301
>
Geotech Report
>
3301 SEAWAY BLVD Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 11:21:11 AM
Creation date
6/4/2019 11:15:49 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
3301
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
177
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
January 13,2016 <br /> Project No. T-7342 <br /> Long-term pavement performance will depend on surface drainage. A poorly-drained pavement section will be <br /> subject to premature failure as a result of surface water infiltrating into the subgrade soils and reducing their <br /> supporting capability. For optimum performance, we recommend surface drainage gradients of at least two <br /> percent. Some degree of longitudinal and transverse cracking of the pavement surface should be expected over <br /> time. Regular maintenance should be planned to seal cracks when they occur. <br /> 6.0 ADDITIONAL SERVICES <br /> Terra Associates, Inc. should review the final design and specifications in order to verify that earthwork and <br /> foundation recommendations have been properly interpreted and incorporated in project design. We should also <br /> provide geotechnical services during construction in order to observe compliance with our design concepts, <br /> specifications, and recommendations. This will also allow for design changes if subsurface conditions differ <br /> from those anticipated prior to the start of construction. <br /> 7.0 LIMITATIONS <br /> We prepared this preliminary report in accordance with generally accepted geotechnical engineering practices. <br /> This report is the copyrighted property of Terra Associates, Inc. and is intended for specific application to the <br /> Seaway Center project in Everett,Washington. This report is for the exclusive use of Bertch Capital Partners and <br /> their authorized representatives. No other warranty,expressed or implied, is made. <br /> The analyses and recommendations presented in this report are based upon data obtained from the test pits <br /> excavated on-site. Variations in soil conditions can occur, the nature and extent of which may not become <br /> evident until construction. If variations appear evident, Terra Associates, Inc. should be requested to reevaluate <br /> the recommendations in this report prior to proceeding with construction. <br /> Page No. 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.