TABLE 4-3 <br /> LISTS MAXIMUM UNIT LOADING & MAXIMUM LENGTH <br /> OF DRAINAGE & VENT PIPING <br /> Size of Pipe (inches) 14 11 2" 22" 3" 4" 5" 6" 8" 10" 12" <br /> Max. Units <br /> Drainage Pipingl <br /> Vertical 0 22 163 323 484 256 600 1380 3600 5600 8400 <br /> Horizontal5 0 1 83 143 354 216 428 720 2640 4680 8200 <br /> Max. Length (Feet) <br /> Drainage Piping <br /> Vertical 0 65 85 148 212 300 390 510 750 <br /> Horizontal Unlimited <br /> Vent Piping <br /> Horizontal & Vertical <br /> Max. Units 16 83 24 48 84 256 600 1380 3600 <br /> Max. Lengths 456 60 120 180 212 300 390 510 750 <br /> (See Note) <br /> 1Excluding trap arm <br /> 2Except sinks & urinals <br /> 3Except six-unit traps or water closets. <br /> 4Only four water closets or six-traps allowed on any vertical pipe or <br /> stack and not to exceed three water closets or six-unit traps on any <br /> horizontal branch or drain provided any one of the three discharges is <br /> separated from the other two by a miminum horizontal developed length <br /> of fifteen (15) feet whether connecting to vertical or horizontal piping. <br /> 5Based upon one-fourth inch (a" ) per foot slope. For one-eighth (1/8" ) <br /> per foot slope multiply horizontal fixture units by a factor of 0. 8. <br /> NOTE: The diameter of an individual vent shall not be less than one and <br /> one-fourth (14") nor less than one-half the diameter of the drain to <br /> which it is connected. Fixture unit load values for drainage and vent <br /> piping shall be computed from Tables Nos. 4-1 and 4-2. Not to exceed one- <br /> third of the total permitted length of any vent may be installed in a hori- <br /> zontal position. When vents are increased one pipe size for their entire <br /> length, the maximum length limitations specified in this table to not apply. <br /> 6Vertical only. <br /> Section 25 <br /> That Chapter 6, Section 613, of the Uniform Plumbing Code <br /> herein adopted, is hereby amended to read as follows : <br /> "Section 613 - Vertical Wet Venting <br /> " (a) Wet venting is limited to vertical drainage <br /> piping receiving the discharge from the trap arm of 1 or 2 <br /> fixture unit fixutres that also serves as a vent for not to <br /> exceed four (4) fixtures. All wet vented fixtures must be <br /> on the same floor. <br /> " (b) The vertical piping between any two consecutive <br /> inlet levels shall be considered a wet vented section. Each <br /> wet vented section shall be a minimum of one (1) pipe size <br /> larger than its upper fixture inlet. The developed length <br /> between two such inlets shall at no time be greater then <br /> five (5) times the diameter of the intervening wet vented <br /> section. <br />