f The rated 1-hour assembly has been noted on the wall section 1/A33, and the tested assembly detail <br /> t/ included on A33. The assembly is specific to both the interior wall condition and the parapet. <br /> 3. Please indicate the method of attachment of the slab and foundation with the thermal break shown on <br /> the insulation detail for the new addition. <br /> Per the structural engineer "a structural connection between the wall and the slab is not required to resolve <br /> c7 soil pressures or seismic forces for this particular project" <br /> Accessibility <br /> / <br /> ✓ 1. The building permit site plan should indicate more detail on the parking signage and the accessible <br /> route to the primary function served, per IBC sections 1104.3, 1106.1, 1106.4, 1106.5 and 1106.6, and <br /> IEBC sections 410.5 and 410.7. The costs for providing the accessible route are not required to exceed <br /> 20% of the cost of the alterations to the primary function area. <br /> a. For your reference, a handout referencing the building code standards ICC/ANSI A117.1-2009 for <br /> several items listed above is attached. <br /> b. Please document the accessible route to the primary entrance door, per ICC-A117.1-2009 section <br /> 403.4. <br /> c. Please indicate conforming curb cuts, if used, and accessible door hardware on the drawings. <br /> d. Accessible parking signage should indicate compliance with height and content of signage per <br /> ICC/ANSI A117.1-2009 section 502.7. <br /> The accessible route has been indicated on the Site Plan,A1.1,as well as a detail for parking signage. There <br /> are no curb cuts needed along the accessible route the paving is flush. Accessible hardware is noted on <br /> the Code Analysis Plan,A1.2 <br /> 2. Please contact Kirk Brooks to discuss the Public Works plan review overlapping concerns of the <br /> following items. Kirk can be reached by e-mail at kbrooks@everettwa.gov a. The width of the exterior <br /> walkway should be shown as 44 inches, per IBC section 1101.2.1, as amended by the State of <br /> Washington. The building code requirement for minimum width of the walkway on the east side of the <br /> building would require work in the public right of way, outside of the property line. <br /> b. The accessible clearance required for the entrance door should be shown to meet the minimum <br /> requirements of ICC/ANSI A117.1-2009 figure 404.2.3.2 (g), which requires 48 inches width of the <br /> landing outside of the doorway. <br /> c. The location of the accessible parking should continue to be on the shortest route to the primary use <br /> and accessible building entrance, per IBC section 1106.6 and IEBC Section 1105.1. The location of the <br /> accessible van parking as shown currently on the plans, and moving that parking space east will be a <br /> challenge for vehicle access so close to the corner of the block. <br /> The Van Accessible space has been moved in consultation with Kirk Brooks. Please refer to the Site Plan, <br /> A1.1. Also on the site plan, the accessible walkway has been widened to 48': These changes are also being <br /> resubmitted to Public Works. <br /> 3. The pull side clearance on the door into the new treatment room should be 18 inches, per per ICC- <br /> A117.1-2009 figure 404.2.3.2 (a). <br /> The pull side clearance dimension has been added to the Floor Plan,A2.1. <br /> Energy <br /> cf 1. Please include a calculated lighting summary from the forms available on'NEEC.NET to verify <br /> compliance for the interior lighting power allowances per WSEC table C405.2 (1)-for the existing tenant <br /> improvement and the addition, per WSEC section C502.6.1 and C503.6. <br /> Separate forms have been submitted for the addition and for the alteration. A22 also includes a light fixtrure <br /> schedule,plan notes and fixture layout. <br /> Morgan Robert Elliott, LLC • 2320 29th Ave S. Seattle, WA 98144 • 206-354-2412 <br />
The URL can be used to link to this page
Your browser does not support the video tag.