�� <br /> GEf� ER I� OTES : � <br /> � <br /> AL CONCRETEe t.� <br /> 1 . DESIGN IS BASED ON THE INTERNATIONAL BUILDING CODE, IBC2012. � • ALL CONCRETE WORK SHALL COMPLY WITH PROVISIONS OF ACI 318-11 , ACI 315-05, <br /> 2. ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH PROJECT DRAWINGS AND AND ACI 301 -10, AND THE INTERNATIONAL BUILDING CODE � <br /> � SPECIFICATIONS 2. CONCRETE SHALL BE NORMAL WEIGHT CONCRETE'. <br /> CONCRETE STRENGTHS (AT 28 DAYS) SHALL BE AS FOLLOWS: a- <br /> 3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONNECTIONS, EMBED PLATE � <br /> AND ANCHOR BOLT LOCATIONS FROM EQUIPMENT MANUFACTURER'S APPROVED PEDESTRIAN ' F'c <br /> DRAWINGS AND STEEL FABRICATOR'S ANCHOR BOLT AND EMBED PLATE SETTING <br /> (BASE SLAB, WALLS, AND ROOF), ---------------------- 5000 PSI <br /> PLANS, WHICH HAVE BEEN APPROVED BY THE ARCHITECT/ENGINEER, � <br /> RETAINING WALLS -------------------------------- 5000 PSI <br /> 4. THE CONTRACTOR SHALL WORK STRUCTURAL DRAWINGS TOGETHER WITH � <br /> CIVIL DRAWINGS TO LOCATE SLOPES, DRAINS, GRADES, ETC. ANY DISCREPANCIES FOUNDATIONS ---------------------------------- 4Q00 PSI <br /> SHALL BE CALLED TO THE ATI�ENTION OF THE ARCHITECT/ENGINEER BEFORE EXTERIOR EXPOSURE ----------------------------- 5000 PSI <br /> PROCEEDING WITH THE WORK. ALL OTHER CONCRETE----------------------------- 4000 PSI - <br /> 5. THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS UPON THE <br /> INTERACTION OF VARIOUS CONNECTED COMPONENTS. PROVIDE ADEQUATE BRACING, 3. CALCIUM CHLORfDE SHALL NOT BE USED IN ANY FORM. }„ <br /> SHORING, AND OTHER TEMPORARY SUPPORTS AS REQUIRED TO SAFELY COMPLETE THE 4. CONCRETE PROTECTION FOR REINFORCING BARS: <br /> WORK. <br /> STRUCTURAL ELEMENT CLEAR COVER <br /> 6. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO FOOTINGS, (CAST AGAINST & <br /> ORDERING ANY MATERIALS AND SHALL NOTIFY THE ARCHITECT/ENGINEER IF DIFFERENT PERMANENTLY EXPOSED TO EARTH --------3 INCHES �"V <br /> FROM WHAT IS SHOWN ON THE DRAWINGS. � �-----� <br /> FOOTINGS AND WALLS (CAST-IN-FORMS o <br /> 7. THE CONTRACTOR SHALL REVIEW THESE DRAWINGS AND VISIT THE PROJECT SITE BEFORE PERMANENTLY EXPOSED TO EARTH) ---------------2 INCHES {� <br /> CONSTRUCTION BEGINS TO COMPARE ALL EXISTING CONDITIONS WITH WNAT IS SHOWN ON SLABS (IN CONTACT WITH EARTH) ----------------2 INCHES <br /> THESE DRAWINGS. IF THERE ARE CONDITIONS WHICH ARE DIFFERENT FROM WHAT IS SHOWN, SLABS (EXPOSED TO WEATHER) -----------------1 1/2 INCHES � <br /> THE STRUCTURAL ENGINEER OF RECORD SHALL BE NOTIFIED. SLABS ABOVE GRADE-----------------------3/4 INCHES � <br /> 8. THE CONTRACTOR SHALL ARRANGE A PRE-CONSTRUCTION MEETING WITH THE '- <br /> � ARCHITECT/ENGINEER TO ENSURE THAT THE CONTRACTOR'S UNDERSTANDING OF THESE 5. ALL REINFORCING STEEL SHALL BE PLACED WITHIN TOLERANCES SPECIFIED IN <br /> DRAWINGS AND PLAN FOR THE WORK IS IN ACCORDANCE WITH THE DESIGN INTENT AND TO SECTIONS 7.5.2.1 AND 7.5.3.3 IN ACI 315-99 �/ <br /> CLARIFY ANY QUESTIONS THAT THE CONTRACTOR MAY HAVE. 6. ALL REINFORCING STEEL REBAR SHALL CONFORM TO ASTM A615 GRADE 60. W <br /> 9. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND 0- <br /> � SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE �• REINFORCING LAP SPLICE TABLE: <br /> PROJECT, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. TOP BARS ARE HORIZONTAL REINFORCEMENT PLACED SO THAT MORE THAN 12" OF <br /> FRESH CONCRETE IS CAST BELOW THE BAR. O <br /> LL <br /> 10. ELEVATIONS: LAP SPLICE LENGTH (4000 PSI CONCRETE) - NORMAL WEIGHT <br /> FINISHED BLDG 40-58 GROUND FLOOR EL = 100'-0" LEAST CONCRETE BAR SIZES (#) <br /> FINISHED GROUND FLOOR REF EL. = 545.5' N.G.V.D. (SEE CIVIL DWGS) COVER AT BAR 3 4 5 6 7 8 9 10 11 <br /> 3" 15" 20" 24" 29" 42" 48" 55" 65" 80" <br /> cn --- <br /> � ,� » » „ „ >, » » >, ,� <br /> D E S G N C R T E R A> m 2 15 20 24 29 46 61 77 9 7 120 <br /> � 1 1/2" 15" 20" 25" 36" 62" 81 " 102" 130" 160" <br /> � 3/4" 18" 32" 50" 73" 106" 121 " 136" 153" 170" <br /> 1 . DESIGN LIVE LOADS: <br /> A. SURCHARGE PRESSURE 250 PSF {TUNNELS AND PORTA�S) 3" 12" 15" 19" 23" 33" 37" 42" 50" 62" <br /> 500 PSF (RETAINING WALLS) <br /> � <br /> 2" 12" 15" 19" 23" 36" 47" 59" 75" 92" <br /> w ,> » » „ >> ,> » » » ,� <br /> B. HS 20 - STANDARD HIGHWAY LOADING. ? 1 1/2 12 15 20 28 48 62 79 100 123 <br /> � 3/4" 14" 25" 39" 56" 81 " 93" 105" 118" 131 " <br /> LAP SPLICE LENGTH (5000 PSI CONCRETE) - NORMAL WEIGHT <br /> 8K I 32K I 32K i LEAST CONCRETE BAR SIZES (#) <br /> COVER AT BAR 3 4 5 6 7 8 9 10 11 <br /> - - - - 3" 13" 18" 22" 26" 38" 43" 49° 58" 72" <br /> v� <br /> Q 2" 13" 18" 22" 26" 42" 54" 69" 87" 107" <br /> m 1 1/2" 13" 18" 23" 33" 55" 72" 92" 116" 143" <br /> � <br /> PLAN � 3/4" 17" 29" 45" 65" 95" 108" 122" 137" 152" <br /> 2. DESIGN WIND LOAD: RE�ERENCE - ASCE 7-10 <br /> 3" 12" 14" 17" 20" 29" 33" 38" 45" 55" <br /> ULTIMATE WIND SPEED, V --------------- 110 MPH � 2" 12" 14" 17" 20" 32" 42" 53" 67" 83" <br /> NOMINAL WIND SPEED ------------------85 MPH � 1 1/2" 12" 14" 18" 25" 43" 56" 71 " 89" 110" <br /> EXPOSURE CATEGORY --------------------C �' 3/4" 13" 22" 35" 50" 73" 83" 94" 105" 117" <br /> OCCUPANCY RISK CATEGORY----------------II <br /> ULTIMATE WIND PRESSURE ------------- +/-43 PSF g. IT IS PERMITTED TO SUBSTITUTE MECHANICAL SPLICES (MEETING THE REQUIREMENTS OF <br /> SECTION 12.6 IN ACI 318-11) FOR LAP SPLICES AT NO ADDITIONAL COST. MECHANICAL <br /> 3, DESIGN SEISMIC LOAD: REFERENCE - ASCE 7-1Q SPLICES SHALL DEVELOP 125� (MIN) OF THE YIELD STRENGTH OF THE REBAR IN TENSION <br /> 1 SECOND MAPPED ACCELERATION, S1 ---------- 0.558g OR COMPRESSION, <br /> SHORT DURATION MAPPED ACCELERATION, Ss------ 1 .447g 9. ALL REINFORCEMENT SHALL BE BENT COLD. REINFORCEMENT PARTIALLY EMBEDDED IN <br /> 1 SECOND DESIGN ACCELERATION, Sd1 --------- 0.558g CONCRETE SHALL NOT BE FIELD BENT UNLESS APPROVED BY THE STRUCTURAL ENGINEER <br /> SHORT DURATION DESIGN ACCELERATION, Sds ------ 0.965g <br /> OF RECORD. HOOKS SHALL BE ACI STANDARD HOOKS IN ACCORDANCE WITH ACI 318, CHAPTER 7. <br /> IMPORTANCE FACTOR ----------------- 1=1 .0 10. REINFORCING FOR CONTINUOUS FOUNDATIONS SHALL BE CONTINUOUS AT CORNERS ' <br /> SITE CLASS------------------------- D AND INTERSECTIONS. PROVIDE CORNER BARS AT ALL CORNERS AND INTERSECTIONS. <br /> CORNER BARS SHALL HAVE LAP LENGTHS EQUAL TO THE STRAIGHT BAR LAP LENGTHS <br /> SEISMIC DESIGN CATEGORY---------------- D ON BOTH ENDS OF THE CORNER BARS. <br /> �0 U N DAT 0 N S o 11 OR OTHERMNON�METALLIC ICOAT NGS THATNDECREASETBONpLL BE FREE FROM MUD, OIL <br /> 1 . FOUNDATION DESIGN IS BASED ON INFORMATION AND RECOMMENDATIONS ° <br /> PROVIDED IN THE GEOTECHNICAL REPORT PREPARED BY LANDAU ASSOCIATES, <br /> DATED MAY 16, 2014. SHALLOW FOUNDATIONS ARE DESIGNED FOR A MAXIMUM <br /> ALLOWABLE SOIL BEARING CAPACITY OF 4,000 PSF. ALL VALUES SHALL BE <br /> VERIFIED BY A REGISTERED GEOTECHNICAL ENGINEER (OR HIS REPRESENTATIVE) <br /> PRIOR TO PLACEMENT OF CONCRETE. <br /> ���,t�.8�1�,��f <br /> 2. SUB-GRADE FOR ALL FOUNDATIONS SHALL BE PREPARED AND x���� ��F,�,��,y�l�'-��, <br /> COMPACTED IN ACCORDANCE WITH RECOMMENDATIONS STATED IN THE }z �� ��� '���y,`�� <br /> GEOTECHNICAL REPORT REFERENCED ABOVE. �aV� �;,��� - �' `� <br /> 02:� s 3 qs-z _ oa�c , <br /> ,� . � <br /> 3. EXCAVATION FOR FOUNDATIONS SHOWN ON DRAWINGS SHALL NOT BE LARGER # <br /> �`` C a � <br /> THAN THE INDICATED FOUNDATION SIZE BY MORE THAN 3" EACH DIRECTION � ���,��t�➢� _����'� <br /> 900 SW 1 Gth 5tr�et �u�t� �07 �r���.. <br /> Renton� �dS�'l1l�P��O11 ����7 David P. Balawajder <br /> WA PE 28184 � <br /> SYM REVISION BY APPROVED DATE SYM REVISION 8Y APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE `� <br /> oF wASH, ACCEPTABILITY KRW 05 30 14 GENERAL NOTES � � � <br /> P�� "�r THIS DESIGN AND OR CHECKED W2534622 05 30 14 � <br /> A ISSUE FOR PERMIT KRW EWB 05/30/14 ��` �� SPECIFICATION IS APPROVED DPB 05 30 14 SHEET ¢ <br /> ,� � BRPHARCHITECTS ENGINEER TIT�E o <br /> ENGINEERSINC. APPROVED BY DEPT. DATE SLJ EWB 05 30 14 40-58 n <br /> No.a�37 CHECKED S L �; ; <br /> m SITE 40-YD N <br /> P,�c �P�o APPROVED JOB No. 16950 COMP NQ. Q <br /> qTF OF AUSN��\ APPROVED DWG N0. � <br /> STRUCTURAL MASTER EVERETT, WA 40-YD-S2 <br /> ` (PAPER SPACE) SEE: 40-YD00_55-C10.DWG <br />