Laserfiche WebLink
_ ,--�_� -- L EG E N D <br /> %� <br /> ,�.��� ��,�� <br /> � � �. � <br /> - � ��� �� � � <br /> i i ROOM AREA(SQ.FT.) � <br /> � � XXX OCCUPANT LOAD FACTOR(S.F./PER.) <br /> � � � NUMBER OF OCCUPANTS(PER.) <br /> ,i � <br /> i i � EXIT SIGN <br /> i � DIRECTIONAL ARROW <br /> I � � <br /> � FIRE EXTINGUfSHER 3A:40B:C <br /> ! I UNLESS NOTED OTHERWISE <br /> . STAIR D2 i i I �H FIRE EXTINGUISHER(HALON 1211, <br /> M 102C2 � NALOTRON 1)2A:10B:C <br /> � ELEVE'�OR 3 -�—�—�—�—�- 1-HOUR WALL RATING . <br /> r <br /> �� _ _ _ �� �� WITH 60 MIN.DOOR RATING U.N.O. <br /> ;I � <br /> STAIR D2 ''; -- T 7 E� 2 2 2 2 2- 2-HOUR WALL RATING <br /> STAIR WIDTH: 60 INCHES � — � WITH 90 MIN.DOOR RATING <br /> STAIR CAPACITY: 200 PERSONS �' � _ � <br /> I I i X MIN. DOOR RATING <br /> STAIR DOOR: 33 INCHES � _ — � � <br /> STAIR DOOR CAPACITY: 165 PERSONS � — __ �; 7 � ;,, <br /> EXIT CAPACITY PROVIDED: 165 PERSONS -- �" <br /> EXIT CAPACITY REQUIRED: 155 PERSONS �f��� � <br /> � � �, � <br /> �- � � � ��� � '� �{ , � ELEV�TOR 4 � <br /> 582 I I I <br /> � TRAINING STOR ( ; -;�- �'� � � � . <br /> 300 �� <br /> � � M103C2 ��I �z � ��� � <br /> � !; �� ��� ,--���, GENERAL NOTES <br /> , ------ - ------- ----r <br /> - -- — — ��_-- --��-_--_ _— --, � � ,. <br /> --LOCKER-RM- --�r�� -�e �o�_� o,�, �� ;,_ � ME�N RR - -- - --____ __ �� <br /> 93 M101 D2 ! �� �__ „! 1 REFER TO OVERALL LIFE SAFETY PLANS FOR MAJOR <br /> r�� ' ` �`�� �%� M1 3D2 <br /> �0 i �: i�� �i� �^� � Q� OCCUPANT LOAD CLARIFICATIONS. <br /> � LOCKER RM �� � �' '- �� � R I„ � � � � <br /> 2 , �� ���� �„ O R�DOR <br /> � M107D2 �� ='� � �;� �� � '�� �� � ii� 2 FOR TOWER LEVELS, A PERFORMANCE BASED DESIGN WAS <br /> � <br /> � rE f � M10��D2 PERFORMED IN LIEU OF PRESCRIPTIVE CODE TRAVEL <br /> • 130 ���' ' DISTANCES IDENTIFIED IN IBC TABLE 1016.2 AS PERMITTED BY <br /> i � �i,' SECTION 104.11 OF THE IBC. AN EVALUATION USING EGRESS <br /> 50 STORAGE _ �„_ � f�_F r, ' � �I A�V MODELING WAS PERFORMED TO DEMONSTRATE THE TRAVEL <br /> 3 ' '-�r-���— _ ° {' - ! DISTANCES IDENTIFIED ARE ACCEPTABLE. <br /> M112H3 � � � —,,� „ - � M10�D2 <br /> , � � <br /> 115 ;� ���,s�s ,,�,� ��� MOTHE�S ROOM � � � <br /> �_�, � � <br /> 0 <br /> 300 ��� ��� 1 b ,-,� ,� 1�I � � <br /> � � � � WOMEN RR � � ���'� 108 s�< �,� i M10�D2 � <br /> I rn`, .s ; i <br /> ' 1 <br /> T <br /> M 108D2 ; ���-> BREAK �M� � <br /> �s� � � I � <br /> T3 � M 1 9D�2 �� �,, �� � <br /> ��,,� � <br /> ✓�{') <br /> �� 'I <br /> . I �5��� Y_vj:2 \. �� _ . . . . <br /> - � ����> I <br /> �� �,i���� Ea I I <br /> � �I, <br /> � INDUSTRIA �,28� ,� ---, ' �!� � <br /> � <br /> i ATHLETE �oo'�� �• ,!� <br /> � <br /> COMM i� M113D2 �s , �-,��: � I i <br /> M110D2 , �� SHAFT D�8 <br /> SYSTEMS '! TN102C�6 <br /> 490 M 111 D2 �-� k � � � <br /> ,.. <br /> i �� � � I <br /> 30o ELEC RM � ������- �� <br /> �� � M112D2 ��i - - -- � �� STAi�E2 � <br /> �� <br /> ��i ''�� �� ���=�� M101 ��F2 �, ' <br /> � <br /> , `__ <br /> - -- ----- - ----- -- - -- - --- - T -- _ _ . - <br /> — — -- - - --— — <br /> _( � � <br /> STAIR E2 � �� — — - — _ — ----- -_ -------- -- <br /> - - i i -- ,,\\__/, <br /> STAIR WIDTH: 60 INCHES ���{� i� � ���� I � <br /> STAIR CAPACITY: 200 PERSONS � ��I ���f�' ���,� ! ; ,; <br /> � �, � i �f� ,��,��,�� I� � ! I COLLAB <br /> STAIR DOOR: 33 INCHES ��i��� � � <br /> STAIR DOOR CAPACITY: 165 PERSONS � � -- i <br /> EXIT CAPACITY PROVIDED: 165 PERSONS �� � -� - - - - M 1 CI��E2 <br /> E X I T C A P A C I T Y R E Q U I R E D: 1 5 4 P E R S O N S � , 0 2 4�� <br /> �� '-�--�''� � � �oo <br /> 357 1�'�_� �� �,��-�I `���'� � �;�' <br /> 15 <br /> � �£� � � <br /> z4 f� ��=i-, u �� � TRAINING <br /> , � <br /> , �, � �� <br /> �; <br /> ;' --- � M10�1E2 . <br /> i, � <br /> CONFERENCE � �� I , ;�' <br />� - �� -=-� � � � � � <br /> �850� � __'. 395 � ( 45 <br /> M102E2 �� .����� � � �� <br /> � �-,�2�_r ` I��, 100 100 <br /> ,� �i,,— l _, � � I i i i <br /> E-TEST � �" ' '�r : , � ' " <br /> ������- -�� 4 ,- - � �_. <br /> CLASSROO �7 '��� �� �� �� � �� � :� :fi. � +� �,.a � ,.� ,.r o , a � <br /> a <br /> M105E2 � .� � COPY/PRINT/MAIL � <br /> ; ����������� � � M1 Q6E2 G�- - � - - � - - � - - � - -}Q <br /> _i �_- � � 10 11 1 <br /> � 3 CLASSROOM � �� '�����A-�' `����:���-,, ( , I G� - � - - - - - - - � <br /> ' �- � � � � � � <br /> ' I I_1�_1 �LJ.� JL1. ��1 I I I <br /> M108E2 ��aa��.� -��20��:: CLASSROOM p - - - � / /, ,�� - /,�'i � . <br /> 24 r � 25 � � � � � � � � �� �� � % <br /> � � ��� �� I i M1(�9E2� �2 � ��3��� / <br /> � TRAVEL DISTANCE: ' � ��'.; � � — — — � �/�� ,�� , � <br /> / <br /> � TO EXIT. 163 FT � � - — � —' — � HANAS ON � � � .� � �/ <br /> � �� � � / �� <br /> ( �i '-I , ss� � �-.� ��i TRAINING � - /�!� �,/ <br /> , , � � � / / /, <br /> � � �� I� �! zo I i CLASSROOM �" - '�' '- - fl <br /> � � � �� �o' � _ � � ���M��1�1� 0E2 � <br /> � I — - - - - - - - - <br /> . --- — — -- -- - — — --- — -- — ��--�--�' -� -�' � ,- --�.,\ �� � � � � � <br /> -- — -- -_-- ��-�-�,� — Y — --- — ----- -- -----{ � � �q <br /> I \ � 15 <br /> �._ i G� - � - - � - - � - - � - -�-0 . <br /> i ' i <br /> � ' o�- — -�- — — -�- — — -�- — — -�- — � <br /> � � <br /> I 16 17 <br /> G� - � - - � - - � - - � -- � <br /> ��� � �. BAHqlj ..� � � <br /> ,�...s� �.t� � <br /> �, ,�wasH�h, n�� � <br /> . PARTIAL LI FE SAFETY PLAN - LEVEL M 1 � E N S E N H U G H ES ��vO. � � Gl ! � T _ ,� _ _ _ _ _ _ � <br /> �T �b 2 <br /> � <br /> � 1� t1.3 1.3 1.7 1.7 0 1 4 5 <br /> SCALE: 1"=20'-0° <br /> 725 Primera Bivd �Suite 215 � �ake Mary, FL 32746 �,'` 517?7 .� �`�^ 0 10' 20' 40' 60' � <br /> P 407.647.3737 � F 4Q7.647.4929 9OO SW �6tI1 Stl"@2t Sll1tE 3O7 � o ��=utsttiF�" �' � <br /> www.jensenhughes.com �' �s <br /> Project: 1HRB00390 Rellt011� Washington 98057 ��� fs�s��v�1-`''`� ����20� Q <br /> � <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE w q g ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE p <br /> oF H, ��B 10/20115 PARTIAL LIFE SAFETY PLAN W2548317 3 10/20/15 � <br /> 0 ISSUE FOR CONSTRUCTION CGB HRB 10109114 P��" N�r THIS DESIGN AND/OR cHECKED <br /> 5 2 SPECIFICATIONISAPPROVED CGB 10120115 SHEET u� <br /> Bo�,�� BRPH a�cHiTECrs ENGINEER TITLE o <br /> 1 REVISION-RELEASE 1 CGB HRB 10/30l14 � <br /> ENGINEERSINC. APPROVED BY DEPT. DATE HRB 'IOIZO/15 BOEING 777X CWC BUILDING �N <br /> 2 REVISION-RELEASE 16(90p TI} CGB HRB O4I21/15 No.s�31 CHECKED M 1 AL� 1 � � <br /> BUILDING 40-58 � <br /> 3 REVISION-RELEASE 29 CGB HRB 10I20115 <br /> ��' � APPROVED � <br /> � %� �° JOB NO. COMP N0. op <br /> 40-58-M 1 AL-13 � <br /> �c�'TF oF AujNo��tiP APPRovEo ARCHITECTURAL MASTER COL. 2.00-4.00/C.5-F EVERETT,WA °WG"o. 40-58-M1AL-13 • <br />