|
DIFFUSER, GRILLE, AND REGISTER SCHEDULE
<br /> MARK MOUNTING MANUFACTURER/
<br /> TYPE MATERIAL AIR FLOW INLET SIZE FACE SIZE NOTES
<br /> NUMBER LOCATION MODEL NUMBER SIZE {INCHES)
<br /> VARIABLE AIR VOLUME TERMINAL UNIT (VAV) SCHEDULE �
<br /> SG1 GRILLE SURFACE PRICE 22DAL ALUMINUM 0-800 CFM 12x10 14x12 1,3,4,5,9 PRIMARY PRIMARY PRIMARY ELECTRIC COIL
<br /> 801 - 1501 CFM 14x12 16x14 AIRFLOW AIRFLOW AIR MAX. INLET
<br /> 1501 - 2700 CFM 24x14 26x16 � UNIT UNIT LEVEL SERVED BY FAN VALVE VALVE PRESSURE NC SIZE FAN VlPH MANUFACTURER MODEL NOTES
<br /> 2701-6000 CFM 36x20 38x22 NO. LOCATION CFM MAXIMUM MINIMUM DROP LEVE (IN) HP
<br /> TI IFC CFM CFM (INCH WG) KW STAGE
<br /> VAV-18-30 2-K/2.0 2ND FLOQR ACU-18 840 840 225 0.5 30 10 3/4 2.4 1 277/1 PRICE FDCA2 1,2,3,4
<br /> SD-3 DIFFUSER SURFACE PRICE ASCD ALUMINUM 1 - 100 CFM 6" DIA 12x12 1,3,4,5,7,8 VAV-18-31 2-K/2.0 2ND FLOOR ACU-18 1020 1020 310 0.5 30 12 3/4 2.9 1 277/1 PRICE FDCA2 1,2,3,4
<br /> 101 -280 CFM 8" DIA 24x24
<br /> 281 -430 CFM 10" DIA VAV-18-32 2-K.25/2.0 2ND FLOOR ACU-18 980 980 225 0.5 30 10 3/4 3.4 1 277/1 PRICE FDCA2 1,2,3,4
<br /> 431 -550 CFM 12" DIA
<br /> 551 -730 CFM 14" DIA VAV-18-33 2-K.25/2.0 2ND FLOOR ACU-18 1170 1170 310 Q.5 30 12 3/4 2.7 1 277/1 PRICE FDCA2 1,2,3,4 •
<br /> VAV-18-34 2-K.5/2A 2ND FLOOR ACU-18 360 360 135 0.5 30 8 1/3 NA NA 277/1 PRICE FDCA2 1,2,3,4
<br /> SD-4 DIFFUSER LAY-IN PRICE ASCD ALUMWUM 1 - 100 CFM 6° DIA 12x12 1,3,4,5,8,9 VAV-18-35 2-K.5/2A 2ND FLOOR ACU-18 300 300 135 0.5 30 8 1/3 NA NA 277/1 PRICE FDCA2 1,2,3,4
<br /> 101 -280 CFM 8° DIA 24x24
<br /> 281 -430 CFM 10" DIA VAV-18-36 2-K.5i2.0 2ND FLOOR ACU-18 200 200 75 0.5 30 6 1/3 NA NA 277/1 PRICE FDC 1,2,3,4
<br /> 431 -550 CFM 12° DIA .
<br /> 551 -730 CFM 14° DIA VAV-18-37 2-K.5/2.0 2ND FLOOR AGU-18 820 820 225 0.5 30 10 3/4 2.5 1 277/1 PRICE FDCA2 1,2,3,4
<br /> VAV-18-38 2-K.75/2.0 2ND FLOOR ACU-18 350 350 135 0.5 30 8 1/3 1.9 1 PRICE FDCA2 1,2,3,4
<br /> LD-5 LINEAR DIFFUSER SURFACE RICE SD650 ALUMINUM 1-200 CFM 48x1 48 1,3,4,5,10
<br /> �i VAV-18-39 2-K.75/2.0 2ND FLOOR ACU-18 260 260 70 0.5 30 6 1/3 1.6 277/1 PRICE FDC 1,2,3,4
<br /> VAV-18-40 2-K.5/2.0 2ND FLOOR ACU-18 700 700 210 0.5 30 8 1/2 3.9 1 277/1 PRICE FDCA2 1,2,3,4 .
<br /> TG5 GRILLE SURFACE PRICE 630 ALUMINUM 1 -400 CFM 22x22 24x24 1,4,5,6
<br /> 760- 2030 CFM 22x22 36x24 1,4,5,6 VAV-18-41 2-K.5/2.0 2ND FLOOR ACU-18 300 300 110 0.5 30 8 1/3 1.9 1 277/1 PRICE FDCA2 1,2,3,4 '
<br /> EG-7 GRILLE LAY-IN PRICE 630 ALUMINUM 1 -200 CFM 6" DIA 12x12 4, 5, 6, 7
<br /> 101 -280 CFM 8" D!A 24x24 NOTES:
<br /> 281 -430 CFM 10" DIA 1. PROVIDE WITH ECM MOTOR.
<br /> 431 -550 CFM 12" DIA 2. PROVIDE WITH FACE MOUNTED ELECTRICAL CONTROLS ENCLOSURE.
<br /> 551 , 730 CFM 14" DIA 3. REFER TO SPECIFICATtONS FOR CONTROL REQUIREMENTS.
<br /> 4. PROVIDE TRANSFORMER TO 24V CONTROL POWER.
<br /> EG8 GRILLE SURFACE PRICE 630 ALUMINUM 1 - 100 CFM 6" DIA 12x12 1, 4, 5, 6, 9
<br /> 101 -280 CFM 8" DIA 14X6
<br /> 281 -430 CFM 10" o�A 22X�o FA N S C H E D U L E �
<br /> 431 -550 CFM 12" DfA
<br /> 551 -730 CFM 14" DIA
<br /> UNIT UNIT DRNE ESP SOUND MOTOR
<br /> LOCATION FAN WEIGHT
<br /> NO SERVICE FAN TYPE TYPE CFM IN WG SONES RPM BHP LBS BASIS OF DESIGN NOTES _
<br /> RG5 GRILLE LAY-IN PRICE 630 ALUMINUM 1 - 130 CFM 12x12 24x12 4, 5, 6,7 RPM HP VOLTS/PH
<br /> 131 -280 CFM 12x12 24x24 KEF-01 R-E.25/2.0 KITCHEN GREASE HOOD UPBLAST DIRECT 1,250 1.5 11 1725 0.8 1725 1 460/3 80 GREENHECK CUE-141-A 1, 2,4, 5, 7, 8, 9
<br /> 281 -500 CFM 16x16 24x24
<br /> 500-1800 22x22 24x24 KEF-02 R-E.25/2.0 KITCHEN GREASE HOOD UPBLAST DIRECT 3,375 2.0 23 1725 2.2 1725 3 460/3 135 GREENHECK CUE-180HP-A 1, 2,4, 5, 7, 8, 9
<br /> KEF-03 R-E.25/2.0 KITCHEN GREASE HOOD UPBLAST DIRECT 3,380 1.7 24 1725 2.0 1725 2 460/3 120 GREENHECK CUE-161-A 1, 2, 4, 5, 7, 8, 9
<br /> RG-6 GRILLE SURFACE PRICE 630 ALUMINUM 1 - 150 CFM 12x12 24x12 1, 4, 5, 6 KEF-04 R-E.25/2.0 PIZZA OVEN UPBLRST DIRECT 685 1.3 15 1495 0.4 1725 1/2 208/1 80 REENHECK CUE-141 HP-VG 4, 5, 6, 7, 8, 9, 11
<br /> 1 -280 CFM 12x12 24x24 KEF-05 R-E.25/2.0 DISH WASHER UPBLAST DIRECT 600 0.8 08 1532 0.1 1725 1/2 208/1 50 GREENHECK CUE-095-VG 3,4, 5, 7, 8, 10, 11 �
<br /> 281 - 500 CFM 16x16 24x24
<br /> 500-1800 22x22 24x24
<br /> SF-11 2-E.37/2.0 KITCHEN INLINE DIRECT 750 0.5 10 1725 0.2 1725 1/3 460/3 60 GREENHECK SQ-100-A 1, 2, 4, 5, 7, 8
<br /> NOTES: (NOT ALL NOTES USED ON THIS SCHEDULE) SF-12 2-E.62/2.0 KITCHEN WLINE DIRECT 2,030 0.5 12 1286 0.4 1725 1/2 460/3 150 GREENHECK SQ-140-A 1, 2, 4, 5, 7, 8
<br /> _ CEILING MOUNTED DEVICES SHALL HAVE WHITE FINISH.
<br /> 1. PROVIDE BORDER FOR SURFACE MOUNTING ON HARD CEILINGS OR WALL OR DUCT MOUNTING. SF-13 2-E.75/2.0 KITCHEN WLINE DIRECT 2,030 0.5 12 1286 0.4 1725 1/2 460/3 150 GREENHECK SQ-140-A 1, 2, 4, 5, 7, 8
<br /> 2. NOT USED. SF-70 CW-F.75/2.3 HANDS-ON TRAINING INLINE DIRECT 2,000 0.5 21 675 0.3 1725 1/2 460/3 150 TWIN CITIES BSI 1, 5, 7, 8
<br /> 3. INSULATE BACK OF DIFFUSERS AND SA PLENUM BOXES.
<br /> 4. PERFORMANCE SELECTION FOR NOISE CRITERIA SHALL NOT EXCEED THE FOLLOWING: EF-70 CW-F.75/2.3 HANDS-ON TRAINING INLINE DIRECT 2,000 0.5 21 675 0.3 1725 1/2 460/3 150 TWW CITIES BSI 1, 5, 7, 8
<br /> SHALL NOT EXCEED A MAXIMUM OF NC = 25-30 FOR EXEC. OFFICES AND CONFERENCE ROOMS.
<br /> SHALL NOT EXCEED A MAXIMUM OF NC = 30 -35 FOR PRIVATE OFFICES COLLABORATION ROOMS. NOTES:
<br /> SHALL NOT EXCEED A MAXIMUM OF NC = 35-40 FOR OPEN-PLAN OFFICES AND LIBRARIES. 1. PROVIDE WITH VFD (BY DIVISION 26). °
<br /> SHALL NOT EXCEED A MAXIMUM OF NC =40-45 FOR COMPUTER ROOMS, FACTORY OFFICES, FACTORY SHOPS AND CONTROL ROOMS. 2. KEF-1, KEF-2, KEF-3, SF-11, SF-12, & SF-13 ARE CONTROLLED BY THE GAYLORD DCV CC?NTROL PANEL.
<br /> SHALL NOT EXCEED A MAXIMUM OF NC= 65 FOR FACTORY MANUFACTURING AREAS. 3. KEF-5 IS INTERLOCKED WITH THE DISHWASHER.
<br /> 5. SEE ARCHITECTURAL SPECIFICATIONS AND DRAWINGS FOR FINISH REQUIREMENTS. 4. PROVIDE OSHA GUARD.
<br /> 6. TRANSITION AS REQUIRED TO MATCH SIZE OF REGISTER OR GRILLE IN�ET OR OUTLET SIZE. 5. PROVIDE PREMIUM EFFICIENCY MQTOR FOR MOTORS ON NON-EC MOTORS.
<br /> 7. PROVIDE BORDER TYPE FOR LAY-IN CEILINGS. 6. WTERLOCK EXHAUST FAN WITH PIZZA OVEN.
<br /> 8. RUNOUT TO DIFFUSER IS TO BE SAME SIZE AS DIFFUSER, GRILLE INLET SIZE, UNLESS NOTED OTHERWISE. 7. PROVIDE SIDE MOUNTED MOTOR.
<br /> 9. PROVIDE FOR ABOVE HARD CEILINGS REMOTE CONTROL SYSTEM FOR BALANCING DAMPER ADJUSTMENT EQUAL TO ZIPSET SYSTEM MODEL ZSA-1 FOR DAMPER ACTUATOR AND MODEL $• PROVIDE HANGING SPRING VIBRATION ISOLATORS.
<br /> CR-1 CEILING RECEPTACLE BRACKET TO CONTROL BALANCING DAMPER POSITION DURWG T&B OPERATIONS. COORDINATE CEILING RECEPTACLE MC)UNTING LOCATION WITH ARCHITECTURAL. 9• EXHAUST FAN FOR TYPE I HOOD.
<br /> 10. PROVIDE 1 SLOT LINEAR DIFFUSER: 1/2" SLOT WIDTH, 48" LONG, FACTORY INSTALLED INSULATION. 10. EXHAUST FAN FOR TYPE II HOOD.
<br /> 11. PROVIDE WITH ECM MOTOR.
<br /> BLOWER COIL UNIT SCHEDULE
<br /> EL.ECTRIC PRE- HEAT COILS) FILTER SECTIONS
<br /> SUPPLY FAN COOLING COILS (43 F EWT, 55 F LWT)
<br /> UNIT NO UNIT AREA SERVED UNIT DESIGN ESP MOTOR TOTAL
<br /> LOCATION SIZE CFM �N WG QTY OF TOTAL EDB EWB TOTAL SENS WPD QN pF FACE EDB LDB TOTAL MAX AP COIL FILTERS .
<br /> COILS GPM ROWS °F °F MBH MBH (FT t1�0) COILS AR� °F °F MBH (IN H O) TYPE WEIGHT NOTES /� TI IFC
<br /> QTY HP V/P/H �FTZ� 2 ACCESS MERV MAX VEL LBS rt
<br /> BCU-70 M1-E.50/2.30 HANDS-ON TRAINING ROOM 4 2000 0.5 1 2 460/3/60 1 12 4 80 67 69.0 50.6 15 1 7.6 22.0 80 125.2 0.14 PRE-HEAT SIDE LOAD 13 500 1300 1,2,3,4,5 .
<br /> NOTES:
<br /> 1. BASIS OF DESIGN: TRANE PERFORMANCE CLIMATE CHANGER.
<br /> 2. MANUFACTURER SHALL PROVIDE PREMIUM EFFICIENCY MOTOR FOR SUPPLY FANS.
<br /> 3. EXTERNAL STATIC PRESSURE (ESP) LISTED DOES NOT INCLUDE AlR FILTERS. 1" INCLUDE IN TOTAL STATIC PRESSURE FOR DIRTY FILTERS.
<br /> 4. VFD PROVIDED BY DIVISION 26.
<br /> 5. PROVIDE WITH 2" BASE RAIL.
<br /> FABRAHOOD GRAVITY EXHAUST / INTAKE SCHEDULE
<br /> UNIT VOLUME SP THROAT HOOD SIZE THROAT SIZE
<br /> UNIT NO. LOCATION SERVICE CFM VELOCITY �
<br /> TYPE (IN WG) �FTJMIN) W�DTH LENGTH HEIGHT W�DTH LENGTH WEIGHT DAMPER MOUNTING REMARKS
<br /> Tenant improvements (TI)
<br /> FGR-70 RF-F.11/2.0 EF-50 EXHAUST 2000 0.08 720 34 39 16 20 20 65 BACKDRAFT ROOF 1, 2, 3, 4
<br /> FGI-70 RF-E.87/2.3 SF-50 INTAKE 2000 0.07 720 37 39 16 20 20 65 BACKDRAFT ROOF 1, 2, 3, 4, 5 H A R G 1 S �� �l,r
<br /> NOTES: ""
<br /> Hargis Engineers, Inc. � � �
<br /> 1. PROVIDE ALUMINUM MESH FILTERS. 3. ALUMINUM CONSTRUCTION. 5. PROVIDE 12" BASE HEIGHT. 1201 Third Avenue, Suite 600 � Seattle, WA 98101
<br /> 2. PROVIDE ROOF CURB. 4. PROVIDE CURB MOUNTED BACKDRAFT DAMPER. t� 206.448.3376 f�206.448.4450 w� hargis.biz �
<br /> 900 SW 16th Street Suite 307 � �11 �
<br /> ENGINEERS�MECHANICAL�EIECTRICAL�TELECOMMUNICATIONS �AL �
<br /> Renton, Washington 98057
<br /> �/z c/�L a �
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE W A s ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE (�y
<br /> � °� N�N� CHECKED 10I20(15 SCHEDULES W2548317 4 10/20/15 N
<br /> 0 Revision-Release 18(IFC TI) LJC RKE 05/19/15 �P o THIS DESIGN ANDIOR RKE 10120115 SHEET �-
<br /> 5 2 SPECIFICATION IS APPROVED �
<br /> 1 Revision-Release 21 (TI) LJC RKE 06/30115 � BENGINERS NCS ENGINEER TITLE BO@IIl 777X CWC BUILDING N
<br /> BOE,�� APPROVED BY DEPT. DATE LJC 10120115 g n /�n \
<br /> 2 Revision-Release 24(TI) LJC RKE 08/11115 r,o.3,s� CHECKED '\/I L r
<br /> N
<br /> P = BUILDING 40-58 " ' N
<br /> � RKE 10I20115 �
<br /> 3 Revision-Release 27(TI Progressj LJC RKE 09/22(15 ,Fc9l � �o APPROVED JOB NO. COMP NO. 4O-5S-M21' �
<br /> 4 Revision-Release 29(TI tFC) LJC RKE 10I20/15 / F OF AUT�� \�P APPROVED MECHANICAL MASTER EVERETT WA owc No. 40-5&M2r -
<br /> ,
<br />
|