Laserfiche WebLink
PLUMBING FIXTURE SCHEDULE TRAP PRIMER SCHEDULE <br /> FLOW NUMBER OF OPER. PRES. ELECTRICAL <br /> MARK DESCRIPTION MANUFACTURER MODEL NO. TYPE SANITARY VENT CW HW RATE REMARKS UNIT TYPE LOCATION SERVICE OUTLETS PSIG AMPS VOLTS PHASE HZ BASIS OF DESIGN NOTES <br /> AMERICAN WALL-HUNG FLUSH �� „ „ STANDARD HEIGHT, WALL HUNG WATER CLOSET VITREOUS CHINA WITH 1 1/2"TOP SPUD INLET 1.28 GPF SENSOR ACTIVATED FLUSH TP-35 2-D.16/2.7 FLOOR SEE PLANS 2p PRECISION PLUMBING <br /> P-1 WATER CLOSET AFWALL 4 2 1 1/4 1.28 GPF VALVE SLOAN#111-1.28 ES-S TMO. PROVIDE EL-154 TRANSFORMER AND ELONGATED, OPEN FRONT SEAT MODEL BEMIS# 1955CT, DRAINS PRODUCTS, INC. PR-500-DU <br /> t STANDARD 2257.101-1.28 VALVE CARRIER: JOSAM NO-HUB HORIZONTAL SERIES 12000. F�OOR <br />� TP-36 2-H.35/2.7 SEE PLANS 20 _ _ _ _ PRECISION PLUMBING <br /> WATER CLOSET AMERICAN AFWALL WALL-HUNG FLUSH ADA HEIGHT, WALL HUNG WATER CLOSET VITREOUS CHINA WITH 1 1/2"TOP SPUD INLET 1.28 GPF SENSOR ACTIVATED FLUSH VALVE DRAINS PRODUCTS, INC. PR-500-DU ' <br /> P-1A 4" 2" 1 1/4" 1.28 GPF SLOAN #111-1.28 ES-S TMO. PROVIDE EL-154 TRANSFORMER AND ELONGATED, OPEN FRONT SEAT MOQEL BEMIS# 1955CT, FLOOR PRECISION PLUMBING <br /> (ADA COMPLIANT) STANDARD 2257.101-1.28 VALVE <br /> CARRIER: JOSAM NO-HUB HORIZONTAL SERIES 12000. TP-37 3-D.16/2.7 DRAINS SEE PLANS 20 - - - - <br /> PRODUCTS, INC. PR-500-DU <br /> STANDARD HEIGHT, COMPLETE SYSTEM WITH SLOAN#186-0.125 ES-S, 0.125 GPF SENSOR ACTIVATED FLUSHOMETER, 3/4"TOP SPUD INLET, FLOOR <br /> AMERICAN WASHBROOK WALL-HUNG FLUSH ADJUSTABLE TAILPIECE AND HIGH BACK PRESSURE VACUUM BREAKER, EL-154 TRANSFORMER. CARRIER: JOSAM 17560-UR SERIES, FLOOR TP-38 3-H.35/2.7 SEE PLANS 20 - - - _ PRECISION PLUMBING <br /> P-2 URINAL STANDARD 6590.001 VALVE 2 2�� 3�4° 0.125 GPF MOUNTED SINGLE URINAL CARRIER WITH HANGER PLATE, BEARING PLATE,ADJUSTAB�E SUPPORTING RODS, STRUCTURAL UPRIGHTS, WELDED DRAINS PRODUCTS, INC. PR-500-DU <br /> FEET AND CHROME-PLATED TRIM. FLOOR <br /> TP-39 2-F.4/2.3 DRAINS SEE PLANS 20 _ _ _ _ PRECISION PLUMBING <br /> ADA HEIGHT, COMPLETE SYSTEM WITH SLOAN#1$6-0.125 ES-S, 0.125 GPF SENSOR ACTIVATED FLUSHOMETER, 3/4"TOP SPUD INLET,ADJUSTABLE PRODUCTS, INC. PR-500-DU <br /> URINAL AMERICAN WASHBROOK WALL-HUNG FLUSH �� �� �� TAILPIECE AND HIGH BACK PRESSURE VACUUM BREAKER, EL-154 TRANSFORMER. CARRIER: JOSAM 17560-UR SERIES, FLOOR MOUNTED SINGLE URINAL FLOOR <br /> P'ZA (ADA COMPLIANT) STANDARD 6590.001 VALVE 2 2 3/4 0.125 GPF CARRIER WITH HANGER PLATE, ADJUSTABLE SUPPORTING RODS, STRUCTURAL UPRIGHTS, WELDED FEET, CHROME-PLATED TRIM AND WHEELCHAIR TP-40 2-E.1/2.1 DRAINS 6 20 2 120 1 60 PRECISION PLUMBING <br /> HEIGHT ROUGH-IN. PRODUCTS, INC. /PT-8 <br /> FLOOR PRECISION PLUMBING <br /> UNDERMOUNT SINK, VITREOUS CHINA, GLAZED UNDERSIDE, 21 1/2°x17 3/8"x7 1/2°WITH OVERFLOW. TP-41 2-E.6/2.0 DRAINS 20 20 2 120 1 60 pRODUCTS INC. /PT-2130 ' <br />� P-3 LAVATORY. AMERICAN OVALYN UNDERMOUNT 1 1/2" 1 1/2" 1/2" 1/2" OA7 GPC FAUCET: AMERICAN STANDARD#6056.105-V035 SELECTRONIC, PROXIMITY OPERATION, CAST BRASS SPOUT, 0.35 GPM, SET AT 12 SECONDS PER CYCLE ' <br /> (ADA COMPLIANT) STANDARD 0497.300 iNCLUDES UNIVERSAL LOW VOLTAGE HARD WIRED TRANSFORMER. ONE TRANSFORMER CAN RUN UP TO 15 FAUCETS. WITH BRADLEY#S59-4000 � � <br /> NAVIGATOR THERMOSTATIC MIXING VALVE W/ 1/2" MALE NPT CONNECTION. PROVIDE MCGUIRE STRAINER/P-TRAP AND SUPPLIES 155A/PWV8912 AND <br /> 1 <br /> ACCESSIBLE WALL HUNG 27°x20", VITREOUS CMINA, SINGLE HOLE WITH OVERFLOW. PROVIDE ZURN 1231 CONCEALED CARRIER. <br /> LAVATORY. AMERICAN WHEELCHAIR FAUCET: AMERICAN STANDARD#6056.105-V035, SELECTRONIC, PROXIMITY OPERATION, CAST BRASS SPOUT, 0.35 GPM, SET AT 12 SECONDS C L EAN O U T S C H E D U L E <br /> P-3A (ADA COMPLIANT) STANDARD USERS WALL MOUNT 1 1/2" 1 1/2" 1/2" 1/2" 0.07 GPC PER CYCLE, INCLUDES UNIVERSAL LOW VOLTAGE HARD WIRED TRANSFORMER. ONE TRANSFORMER CAN RUN UP TO 15 FAUCETS. WITH <br /> 9140.047 BRADLEY#S59-4000 NAVIGATOR THERMOSTATIC MIXING VALVE W/ 1/2" MRLE NPT CONNECTION. <br /> PROVIDE MCGUIRE STRAINER/P-TRAP AND SUPPLIES 155A/PWV8912 AND 2165LK. CLEANOUT APP�ICATION MARK TYPE ZURN JOSAM J.R. SMITH <br /> LAVATORY. AMERICAN OVALYN UNDERMOUNT SINK, VITREOUS CHINA, GLAZED UNDERSIDE, 21 1/2°x17 3/8"x7 1/2"WITH OVERFLOW. <br /> P�3B (ADA COMPLIANT) STANDARD 0497.300 UNDERMOUNT 1 1/2" 1 1/2" 1/2" 1/2" 0.07 GPC FAUCET: DYSON AIRBLADE TAP, 0.35 GPM, SET AT 12 SECONDS PER CYCLE. INCLUDES DEDICATED 15 AMP CIRCUIT. LOW VOLTAGE=11.7 AMPS AT 120V. FINISHED CONCRETE FLOOR FCO ROUND ZN-1400-IC-BP 55000-2-X 4228-C <br /> WITH BRADLEY#S59-4000 NAVIGATOR THERMOSTATIC MIXING VALVE W/ 1/2" MALE NPT CONNECTION. PROVIDE MCGUIRE STRAINER/P-TRAP AND (CAST IRON BODY, BRONZE PLUG, NICKEL BRONZE TOP) SQUARE ZN-1400-IC-BP-T 55000-2-SQ-X 4048-C <br /> t� SUPPLIES 155A/PWV8912 AND 2165LK. FINISHED WALL <br /> 58910-19 & 58600 <br /> P-4 SINK ELKAY ELUHAD2816 UNDERMOUNT 1 1/2" 1 1/2° 3/4" 3/4" 1.30 GPM �8��X16"X5 1/2" DEEP, ADA COMPLIANT, SS UNDERCOUNTER, SWGLE COMPARTMENT, FAUCET: GROHE 3134900E-SOLID BRASS BODY, <br /> (CAST IRON BODY, BRONZE PLUG, STAINLESS STEEL COVER) WCO ROUND ZN-1446-BP (COVER) 4532-S � <br /> SING�E LEVER HANDLE, 1.5 GPM. CONTRACTOR TO ADJUST FLOW IN FIELD TO 1.3 GPM. <br /> PROVIDE MCGUIRE STRAINER/P-TRAP AND SUPPLIES 151A/2165LK AND PWV8912. EXPOSED PIPING C� HORIZONTAL ZN-1400 58900 4420-C <br /> BI-LEVEL (CAST IRON BODY, BRONZE PLUG) VERTICAL ZN-1445 58910 4512-S <br /> P-7 ELECTRIC WATER ELKAY LVRCGNTL8WSK DOUBLE STATION 1 1/2" 1 1/2" 1/2" -- __ BI-LEVEL, SELF-CONTAINED, DOUBLE WALL HUNG ELECTRIC, REFRIGERATED WATER COOLER WITH BOTTLE FILLING STATION, HIGH <br /> COOLER-ADA WALL MOUNTED EFFICIENCY, HERMETICALLY SEALED, RECiPROCATING TYPE MOTOR COMPRESSOR, 115 VOLTS/60 HZ, SINGLE PHASE; 3.8 FULL LOAD AMPS. TILED AREA FCD ROUND ZN-1400-IC-BP-X 55000-2-12-X 4168-C <br /> MOLDED STONE, 10" HIGH WALLS WITH 1"WIDE SHOULDES, STAINL,ESS STEEL DRAIN BODY WITH COMBINATION DOME STRAWER AND (CAST IRON BODY, BRONZE PLUG, NICKEL BRONZE TOP) SQUARE ZN-1400-IC-BP-T 55000-2-12-SQ-X 416$-C <br /> P-9 MOP SINK AMERICAN 7741.000 FLOOR MOUNTED 3" 2" 1/2" 1/2" -- STAINLESS STEEL LINT BASKET. FAUCET: SPEAKMAN MODEL SG5812 WITH SEF-9200 SAFETY EYEWASH -WALL MOUNTED, CHROME <br /> STANDARD PLATED WITH VACUUM BREAKER, INTEGRAL STOPS ADJUSTABLE WALL BRACE, PAIL HOOK AND 3/4" HQSE THREAD ON SPOUT. CARPETED AREA FCO <br /> (CAST IRON BODY, BRONZE PLUG, NICKEL BRONZE TOP) ROUND ZN-1400-IC-BPCF 55000-2-CFC-X 4028C-Y <br /> : <br /> ICE MAKER BOX _ HIGH IMPACT POLYSTYRENE, 2 SUPPORT BRACKETS, SNAP-ON FACE PLATE FRAME ACCOMMODATES UP TO 1" DRYWALL, 1/4 TURN BRASS BALL VALVE, 7ERRAZZO AREA ROUND ZN-1400-IC-BP-Z 55000-2-13-X 4188-C <br /> P-16 W�SHUT-OFF VALVE OATEY 38574 RECESSED WALL BOX 3/8" DIMENSIONS: BOX 6 W x 6 H x 3-3/8 D, FACE PLATE-8-1/4 W x 8-1/4 H FCO <br />,� (CAST IRON BODY, BRONZE PLUG, NICKEL BRONZE TOP) SQUARE ---- 5500-2-13-SQ-X 4208-C <br />�� <br /> P-17 WALL BOX WITH OATEY 38799 RECESSED WALL BOX 2" 2° -- -- -- HIGH IMPACT POLYSTYRENE, 4 SUPPORT BRACKETS, SNAP-ON FACE PLATE FRAME ACCOMMODATES UP TO 1" DRYWALL. DEXOTEX AREA FCO <br /> DRAIN CONNECTION ____ <br /> (CAST IRON BODY, BRONZE PLUG, NICKEL BRONZE TOP) ROUND ZN-1400-IC-BPDX 58000-30 <br /> UTILITY ELKAY 24"X24"X12-3/4" DEEP, 16 GAUGE SS, FLOOR MOUNTED, SINGLE COMPARTMENT SCULLERY SINK. FAUCET: ELKAY LK940AT08L2H, SOLID BRASS <br /> P-18 SINK RNSF8124 FLOOR MOUNTED 1-1/2" 1-1/2" 3/4" 3/4" 1.5 GPM gODY, CHROME FINISH WITH 1.5 GPM AERATOR WSERT, TWO HOLE, DUAL HANDLE, WA�L MOUNTED. PROVIDE MCGUIRE STRAiNER/P-TRAP AND 1 IFC TI <br /> SUPPLIES 151A/2165LKAND PWV8912. <br /> MOLDED STONE, 10" HIGH WALLS WITH 1"WIDE SHOULDES, STAINLESS STEEL DRAIN BODY WITH COMBINATION DOME STRAINER AND 2 WHA - S IZI N G C HART <br /> P-19 MOP SINK FIAT MSBID2424 FLOOR MOUNTED 3" 2" 1/2" 1/2" '- STAINLESS STEEL LINT BASKET, FAUCET: SPEAKMAN MODEL SG5812 WITH SEF-9200 SAFETY EYEWASH -WALL MOUNTED, CHROME <br /> PLATED WITH VACUUM BREAKER, INTEGRAL STOPS ADJUSTABLE WALL BRACE, PAIL HOOKAND 3/4" HOSE THREAD ON SPOUT. <br /> _ <br /> WATER SUPPLY <br /> �� ARRESTOR SIZE PDI STD WH 201 -TABLE V <br /> CAST IRON TWO-PIECE BODY WITH DOUBLE FLANGE INVERTIBLE FLASHING COLLAR, WEEPHOLES, BOTTOM OUTLET 1/2 TRAP PRIMER TAP. PROVIDE FIXTURE UNITS <br /> FD-1 FLOOR DRAIN JOSAM 30000-A-6A SANITARY WASTE 3�� 2�� "- -� FLOOR DRAIN WITH DEEP SEAL"P"TRAP-TRAP PRIMER MODEL PPP#FVP-1VB WITH VACUUM BREAKER, 1-1/2"x12" CHROME PLATED 17 GAUGE FLUSH <br /> VALVE PR►MER TUBE WITH 1/2° COMPRESSION FITTING, 5/8" SHALLOW CHROME FLANGE, 1/2" CHROME PLATED TRAP PRIMER LINE. 1/2" 1-11 PDI-A <br /> r� <br /> FD-2 FLOOR DRAIN JOSAM 30000-A-6A SANITARY WASTE 4" 2° <br /> -- -- -- CAST IRON TWO-PIECE BODY WITH DOUBLE FLANGE, INVERTIBLE FLASHING COLLAR, WEEPHOLES, BOTTOM OUTLET 3/4" 12-32 PDI-B � <br /> 1/2"TRAP PRIMER TAP. PROVIDE FLOOR DRAIN WITH DEEP SEAL"P"TRAP-TRAP PRIMER MODEL PPP#MPB-500-115V <br /> 1" 33-60 PDI-C <br /> FS-1 FLOOR SINK �OSAM 49360A SANITARY WASTE 4" 2" 12"x12"x10" DEEP, CAST IRON BODY WITH WHITE ACID RESISTING PORCELAIN ENAMEL INTERIOR. BOTTOM OUTLET DOUBLE DRAINAGE FLANGE <br /> (KITCHEN AREA) ALUMINUM ANT!-SPLASH INTERIOR BOTTOM DOME STRAINER AND CAST 1RON, NON-TRAFFIC, PORCELAIN COATED ANTI-TILTiNG GRATE. 1-1/4" 61-133 PDI-D <br /> FLOOR SINK 12"x12"x6" DEEP, CAST IRON BODY WITH WHITE ACID RESISTING INTERIOR, BOTTOM OUTLET DOUBLE DRAINAGE FLANGE.ALUMINUM ANTI-SPLASH 1-1/2" 114-154 PDI-E <br /> FS-2 (KITCHEN AREA) �OSAM 49320A SANITARY WASTE 4" 2�� '- -- -+ INTERIOR BOTTOM DOME STRAINER, ACiD RSISTING, ANTI-TILTING GRATE. <br /> 2" 155-330 P D I-F <br /> WATER PRECISION <br /> WHA HAMMER PLUMBING SC SERIES <br /> ARRESTOR PRODUCTS <br />� <br /> DOMEST�C HOT WATER HEATER SCHEDULE <br /> EXPANSION TANK SCHEDULE � � <br /> BASIS OF DESIGN STORAGE SYSTEM RECOVERY GAS ELECTRICAL UNIT NO. UNIT LOCATION BASIS OF DESIGN TOTAL MAX. SYSTEM TANK <br /> UNIT NO. UNIT LOCATION TYPE MANUFACTURER AND (GALLONS STORAGE INPUT VENT HEATER TYPE MANUFACTURER AND VOLUME ACCEPTANCE CONNECTION SIZE NOTES <br /> ) (GPH) @ 100°F gTU'S TYPE �NLET SIZE NOTES " " <br /> MODEL EACH (TEMP °F) EACH (INCH} (D°XH") VOLTS PHASE HZ KW MODEL (GALLONS) (GALLONS) (INCH) (D XH ) <br /> ET-11 2-D/2.70 INLWE WATTS- DETA 12 5 3.3 3/4 (12"X 14") -- <br /> HWH-11 2-D/2.8 ELECTRIC A.O. SMITH - DEN-66 66 140 41 -- -- -- (22"x61") 480 3 60 10 1,2,3,4 <br /> , <br /> - 2 2-H.5/2.8 ELECTRIC A.O. SMITH - DEN-66 66 140 41 -- -- -- (22"x61") 4$0 3 60 10 1,2,3,4 ET-12 3-H.25/2.70 INLINE WATTS - DETA 12 5 3.3 3/4 (12"X 14") -- ` <br /> HWH-13 2-D.90/2.30 ELECTRIC LOCHINVAR HV*kW-300 300 140 185 -- -- -- (40"x80") 480 3 60 45 1,2,3 <br /> - <br /> ET-13 2-D.90/2.30 INLINE WATTS - DETA 30 15 10 1 16 X 24 ) ' <br />� HWH-23 M-F.03I2.0 ELECTRIC EEMAX- EX100 -- -- -- 33,986 -- -- (10"Hx6"Wx3"D) 277 1 60 10 4 � IFC TI � �� �� "' <br /> NOTES: ' <br /> 1. ROUTE T&P VALVE DISCHARGE TO FLOOR DRAIN. INSULATE ALL DOMESTIC WATER PIPE AND LABEL PER SPECIFICATIONS. <br /> 2. PROVIDE AND �NSTALL THERMAL EXPANSION TANK. <br /> 3. OUTLET TEMPERATURE SHALL BE SET AT 140° ON WATER HEATERS. <br /> 4. PROVIDE THERMOSTATIC MIXING VALVES AT ALL WATER HEATERS WITH OUTLET TEMPERATURE SET AT 110°. M I X I N G VALVE S C H E D U L E <br /> I N STANTAN EO U S H OT WATE R H EATE R SC H E D U LE �NIT NO. UNIT LOCATION MANUFACTURER/MODEL NO. MIN. GPM MAX GPM NOTES <br /> TMV-12 2-D/2.70 BRADLEY S59-3080 2.0 77 1, 2, 3 <br /> BASIS OF DESIGN TEMP FLOW PRESSURE HEATER ELECTRICAL <br /> UNIT NO. UNIT LOCATION TYPE MANUFACTURERAND RISE RATE ELEMENTS DROP ORIENTATION WEIGHT SIZE NOTES TMV-13 3-H.25/2.70 BRADLEY S59-3080 2.0 77 1, 2, 3 <br />�� MODEL (°F) (GPM) (#) (PSI) (LBS) (W"XH") VOLTS PHASE HZ KW <br /> HWH-14 2-D.90/2.30 ELECTRIC HUBBELL- HX042-6T4 25 10 6 4 WALL MOUNT 38 (18"x25°j 480 3 60 42 1 TMV-14 2-D.90/2.30 BRADLEY S59-3080 2.0 77 1, 2, 3 <br /> NOTES: <br /> 1. OUTLET TEMPERATURE SHALL BE SET AT 165° ON WATER HEATER. NOTES: <br /> 1. SET OUTLET TEMPERATURE TO 110°F. <br /> 2. MIXWG VALVE SHALL BE INSTALLED AND PIPED ACCORDWG TO MANUFACTURER'S REQUIRED PIPING METHOD. . <br /> 3. SEE GAS WATER HEATER DETAIL ON SHEET P524. <br /> HOT WATER RECIRCULATING PUMP SCHEDULE <br /> BASIS OF DESIGN ELECTRICAL <br /> TYPE MANUFACTURER AND FLOW FT OF <br />� UNIT NO. UNIT LOCATION RPM NOTES <br /> MODE� (GPM) HEAD MOTOR VOLTS PHASE HZ <br /> (HP) , <br /> Tenant Improvements (TI) <br /> CP-08 2-DI2.70 INLINE TACO- 1400-45 3450 3 36 1/3 115 1 60 �,2 <br /> : <br /> CP-09 3-H.25/2.70 INLINE TACO- 1400-45 3450 4 36 1/3 115 1 60 �,2 H � � G � S K� �L j <br /> CP-10 2-D.90/2.30 INLINE TACO- 1400-45 3450 2 36 1/3 115 1 60 �,2 Hargis Engineers, Inc. O , O <br /> 1201 Third Avenue, Suite 600 � Seattle, WA 98101 <br /> NOTES: t � 206.448.3376 f� 206.448.4450 w� hargis.biz <br /> 1. BALANCING VALVES SHALL BE PROVIDED FOR ALL CIRCULATING SYSTEMS, VALVES SHALL BE SET TO FLOW RATES SHOWN UNLESS NOTED OTHERWISE. "� 50811 � <br /> 2. PROVIDE TACO TIMER AND AQUASTAT(265-3 AND 563-2) FOR EACH PUMP LOCATION. 9OO SW �6tI1 $tC@@t Slllt2 3O7 <br /> ENGINEERS�MECHANICAL•ELECTRICAL•TELECOMMUNICATIONS <br /> Renton, Washin ton 98057 �u �� <br />� � �/z�/�� � <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE WA S ACCEPTABILITY DRAWN DATE SUBTITI�E CURRENT REVISION SYMBOL DATE M • <br /> �� oF y�Nc ,AJH 01126/16 W2548317 01/26/16 � <br /> 0 REVISION-RELEASE 18(IFC TI) AJH RKE 05/19115 ,�P r TNIS DESIGN ANDIOR CHECKED M EC HAN I CAL SCH E DU LES Z c- <br /> 5 � SPECIFICATION IS APPROVED RKE 01126/16 SHEET � <br /> BRPH ARCHITECTS ENGINEER TITLE r- <br /> 1 REVISION-RELEASE 29 QFC Tq AJH RKE 10120/15 � EN�NEERs,N�. Boeing 777X CWC BUILDING <br /> 2 REVISION-RELEASE 35 TI AJH RKE 01l26/16 BOE,�� APPROVED BY DEPT. DATE RKE 01126116 nA ^ N <br /> � � N0.3137 CHECKED I\/I�\ <br /> - � BUILDING 40-58 " � � <br /> �'� o APPROVED JOB NO. COMP NO. <br /> F% ti�-� 40-5$-MZs � <br /> 9TF oF Au�N°�'� APPRov�° MECHANICAL MASTER EVERETT, WA 40-58-M2s ¢ <br /> DWG NO. <br />