3003 W CASINO RD 2017 BLDG 40-58 Plans 2022-11-09
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD 2017 BLDG 40-58 Plans 2022-11-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 10:28:04 AM
Creation date
6/17/2019 10:00:42 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
B1708-033
Year
2017
Notes
PAINT BOOTHS 3 AND 4
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
247
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P2P MAKE-UP AIR UNIT SCHEDULE - PAINTIPREP BOOTH#2 <br /> CALLOUT SUPPLY FAN FILTER HOT WATER COIL ELECTRICAL BASIS OF DESIGN <br /> TOTAL MAX MOTOR[9] <br /> MIN SUPPLY DRIVE CFM MAX MAX CONTROL BRANCH <br /> AIRFLOW AIR FAN TYPE PER E.S.P. (IN RPM MAX VEL HHW FLUID TYPE WPD VALVE PD PIPE SIZE <br /> TYPE MARK LOCATION SERVICE (CFM) [2] (CFM) TYPE [8] FAN [1] WC) [3] QTY [1] RPM HP BHP [5] TYPE [4] (FPM) EAT LAT EWT GPM [1] [7] (FT) (PSI) (IN) VOLTAGE PHASE FREQUENCY MANUFACTURER MODEL NOTES � <br /> MAU 06 P2P-CONTROL ROOM CORRIDOR P2P-DOGHOUSE 3 &4 1800 1800 FC BELT 1800 1.65 1 2268 1800 3.0 2.5 MERV 8/MERV 13 540 27 °F 77 °F 135 °F 5.7 0% 0.9 10 1 1/2° 460 3 60 CARRIER 39MN [6] [10] <br /> SCHEDULE NOTES; <br /> [1]WITH UNIT AT MAXIMUM CONDITIONS <br /> [2] MINIMUM UNIT AIRFLOW, FOR GENERAL EXHAUST MAKEUP AIR. SEE SEQUENCE OF OPERATION, <br /> [3] STATIC PRESSURE EXTERNAL TO UNIT, DOES NOT INCLUDE DIRTY FILTER ALLOWANCE <br /> [4] 2" MERV 8 FILTER& 12" MERV 13 FILTER <br /> [5] MAXIMUM ALLOWABLE MOTOR BRAKEHORSEPOWER AT MAX FLOW AND TSP <br /> [6] MAXIMUM RADIATED SOUND POWER LEVELS OF THE UNIT SHALL NOT EXCEED 85 dBA <br /> [7] WATER ENTERING WITH ETHYLENE GLYCOL AT THE PERCENTAGE NOTED � <br /> [8) PROVIDE WITH INITIAL SET OF SHEAVES FOR FAN(S) TO MEET CONDITIONS AS SCHEDULED. FOLLOWING (NSTALLATION AND BALANCENG, PROVIDE REPLACEMENT SET OF SHEAVES FOR ACTUAL CONDITIONS, REGARDLESS OF WHETHER CONSTANT OF VARIABLE SPEED FAN(S)" <br /> [9] PROVIDE VFD RATED MOTOR, SEE ELECTRICAL DESIGN FOR VFD SPECIFICATIONS. ELETRICAL TO PROVIDE VFD, VFD TO BE FIELD INSTALLED <br /> [10] PROVIDE MANUFACTURER INSTALLED TERMINAL JUNCTION BOX ON EXTERIOR OF UNIT CASING INCLUDING ALL WIRING NECESSARY FOR VFD OPERATION AND CONTROL. PROVIDE ONE JUNCTION BOX PER VFD. <br /> , ... �.... ."...,.,.,-,_ .,....�.,.,.._ . �,...,,, .._. ..,,.,.., .,.. <br /> AIRFLOW CAPACITY LIMITS (CFM) NOMINAL SIZE (IN) NECK DIMENSIONS (IN) BASIS OF DESIGN <br /> FOR RECTANGULAR MAX TSP DROP <br /> CALLOUT AIR TERMINAL DESCRIPTION MAXIMUM MINIMUM LENGTH WIDTH DIAMETER LENGTH WIDTH MAX NC (IN.W.G.) MATERIAL OPD FINISH MANUFACTURER MODEL NOTES <br /> SG-1 SIDEWALL MOUNTED ADJUSTABLE DUAL DEFLECTION SUPPLY GRILLE 360 360 10° 14° 8" 12" 20 OA5 ALUMINUM Yes #26 WHITE TITUS 300FL <br /> EG-1 SURFACE MOUNTED EXHAUST GRILLE 200 200 10" 14" 8" 12° 20 0.02 ALUMINUM Yes #26 WHITE TITUS 350FL <br /> RG-1 SIDEWALL MOUNTED RETURN GRILLE 215 215 10" 14" 8" 12" 20 0.02 ALUMINUM Yes #26 WHITE TITUS 350FL � <br /> SD-3 MODULAR CORE SQUARE CEILING DIFFUSER 350 226 24° 24" 10" 10° 17 0,03 STEEL No #26 WHITE TITUS MCD <br /> P2P VAV BOX SCHEDULE - SPRAY/PREP BOOTH #2 <br /> AIRFLOW <br /> CALLOUT SETPOWT ELECTRIC REHEAT COIL DUCT CONNECTIONS ELECTRICAL BASIS OF DESIGN <br /> ENTERING CAPACI7Y <br /> MIN INLET HEATING AIR DRY CONTROL pRIMARY OUTLET DIMENSIONS <br /> EQUIPMENT DESIGN MIN STATIC CAPACITY BULB (DEG CONTROL AIR INLET � <br /> TYPE MARK LOCATION SERVED FLOW FLOW PRESSURE KW F) TYPE DIAMETER HEIGHT WIDTH VOLTAGE PHASE FREQUENCY MANUFACTURER MODEL NOTES <br /> VAV 6 CONTROL ROOM LEVEL ACU-28 800 800 0,35 5 55 SCR 8" 10" 8" 277 1 60 ENVIROTEC SDR-8-EH <br />�� <br />� <br />� <br />� <br /> � <br />� <br /> 900 SW 16th Street Suite 307 FSi consulting engineers <br /> Renton, Washin�ton 98057 Solutions & Service . <br /> — — � <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE �' <br /> NJH 01/10l17 HVAC EQUIPMENT SCHEDULES � <br /> W2548317 � <br /> 0 Issue For Construction FSi BSC 03/08/16 � W• Cq THIS DESIGN AND/OR CHECKED 01/10/17 0 <br /> �'-cF' ��i, �' SPECIFICATION IS APPROVED RED 01/10117 sHEET ,,ri <br /> 1 Revision-Release 44 FSi BSC 06/02/16 � �.�y�l�`" �'-� p ENGINEER TITLE t�. <br /> BO�,�� z APPROVED BY DEPT. DATE BSC 01110/17 Boeing 777X CWC BUILDING <br /> 2 Revision-Release 59 FSi BSC O"I/'IOI�T CHECKED M 2va C <br />� <br /> 4P��Fs '�Te� ��`'�`� APPROVED B U I LD I N G 40-58 0 <br /> s�ONAL EN RED JOB NO. COMP NO. � <br /> o���o��� APPRovEo MECHANICAL MASTER EVERET W 40-58-M2va ¢ <br /> T, A owc rvo. 40 58 M2va <br />