3003 W CASINO RD 2017 BLDG 40-58 Plans 2022-11-09
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD 2017 BLDG 40-58 Plans 2022-11-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 10:28:04 AM
Creation date
6/17/2019 10:00:42 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
B1708-033
Year
2017
Notes
PAINT BOOTHS 3 AND 4
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
247
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� P2P PROCESS AIR CONDITIONING UNIT SCHEDULE • PAINT/PREP BOOTH#2 <br /> � CALLOUT SUPPLY FAN [15] [16] FILTER HEATING COIL BASIS OF DESIGN <br /> MqX MOTOR[5] (12] <br /> DESIGN FAN TYPE DRIVE CFM E.S.P. (IN RPM MAX MAX VEL EAT LAT EWT HHW GPM MAX WPD CONTROL BRANCH PIPE <br /> TYPE MARK LOCATION SERVICE CFM [4] TYPE [4] [1] [4] WC) [3] [4] QTY [1] (4] RPM HP BHP [6] TYPE (7] (FPM) (DEG F) (DEG F) (DEG F) [1] (FT) [1] VALVE PD (FT) SIZE [2� MANUFACTURER MODEL NOTES . <br /> PACU 3 MECH MEZZANINE PREP BOOTH 49200 PLENUM DIRECT 8200 3.60 6 1919 1800 15 8,5 MERV 8/MERV 13 500 20 70 180 135 46.20 10.00 21/2" CARRIER 39CC (8] [9] [10] [12] [14] [18] <br /> PACU 4 MECH MEZZANINE PAINT BOOTH 82000 PLENUM bIRECT 13667 3.60 6 1761 1800 25 16.8 MERV 8/MERV 13 500 20 70 180 220 32.40 10.00 21/2" CARRIER 39CC [8] [9] [10] [12] [17] (18J <br /> SCHEDULE NOTES; <br /> [1] WITH UNIT AT DESIGN FLOW UNDER NORMAL CONDITIONS. <br /> (2] BRANCH SIZE PER COIL. <br /> [3] STATIC PRESSURE EXTERNAL 70 UNIT, INCLUDES DIRTY FILTER ALLOWANCE, <br /> [4] VALUE PROVIDED IS BASED ON EACH INDIVIDUAL FAN, <br /> [5]VALUE PROVIDED IS BASED ON EACH INDIVIDUAL MOTOR. <br /> [6] MAXIMUM ALLOWABLE MOTOR BRAKEHORSEPOWER AT MAX DESIGN FLOW AND ESP UNDER NORMAL CONDITIONS. <br /> [7] 2" MERV 8 PRE-FILTER& 12" MERV 13 FINAL FILTER. <br /> [8] MAXIMUM RADIATED SOUND POWER LEVELS OF THE UNIT SHALL NOT EXCEED 85 dBA. '. <br /> [9] COORDINATE OVERALL UNIT LENGTH, WIDTH & HEIGHT, AIR INLET AND OUTLET OPENING PLACEMENT AND DIMENSIONS- SEE M522-1.3, M522-1.4 <br /> [10] PROVIDE WITH OSA/SUPPLY PLENUM. <br /> [11J PROVIDE SEPARATE DISCONNECT FOR EACH MOTOR, SEE ELECTRICAL DESIGN FOR VFD SPECIFICATIONS. ELETRICAL TO PROVIDE VFD, VFD TO BE FIELD INSTALLED. PROVIDE JUNCTION BOX ON EXTERIOR OF UNIT CASING FOR ELECTRICAL CONNECTIONS, <br /> [12] PROVIDE MANUFACTURER INSTALLED TERMINAL JUNCTION BOX ON EXTERIOR OF UNIT CASING INCLUDING ALL WIRING NECESSARY FOR VFD OPERATION AND CONTROL. <br /> [13] NOT USED <br /> - (14] IN ADDITION TO SCHEDULED CONDITI4NS, UNIT SHALL BE SELECTED TO ALSO ACCOMODATE THE FOLLOWING OPERATING CONDITIONS: DESIGN CFM =41,000 CFM;NEATiNG COIL LAT= 160 DEG F. <br /> [15] FANS AND MOTORS SHALL BE SELECTED FOR N+1 REDUNDANCY. <br /> [16] PROVIDE WITH FACTORY WSTALLED PIEZOMETER FLOW MEASUREMENT DEVICE FOR EACH FAN WITH PNEUMATIC TUBING ROUTED TO AN EXTERNAL JUNCTION BOX. PROVIDE FIELD INSTALLED TEMPERATURE COMPENSATING TRANSDUCERS FOR AIRFLOW <br /> MONITORING AND CONNECT TO EXTERNAL JUNCTION BOX, <br /> [17] IN ADDITION TO SCHEDULED CONDITIONS, UNIT SHALL BE SELECTED TO ALSO ACCOMODATE THE FOLLOWING OPERATING CONDITIONS; HEATING COIL LAT = 120 DEG F; DESIGN AIRFLOW ADJUSTED TO ACCOMODATE NOTED LAT WITHOUT CHANGE IN HEATING COIL SIZING. <br /> [18] UNIT SHALL BE CONFIGURED TO ALLOW SERVICE AND MAINTENANCE ACCESS TO ALL COMPONENTS IN UNIT FROM ONE SIDE OF UNIT. SEE PLANS FOR IDENTIFICATION OF ACCESSIBLE SIDE. � <br /> P2P PROCESS EXHAUST FAN SCHEDULE - PAINTIPREP BOOTH #2 <br /> CALLOUT FAN ELECTRICAL BASIS OF DESIGN <br /> DESIGN FAN FLOW MOTOR[3] (6] [9] <br /> FLOW(CFM) TYPE DRIVE (CFM) E.S.P. <br /> TYPE MARK LOCATION SERVICE [6] [8] TYPE (8] [8] (IN.W.G.) (1] (8] QUANTITY RPM [8] RPM HP BHP [2] VOLTAGE PHASE FREQUENCY NOTES <br /> EF 51 APRON LEVEL NORTH OF GRID 4.0 PREP BOOTH 54120 PLUG V-BELT 13,530 5.00 4 1,350 1,800 20 12.2 460 3 60 CARRIER 39 CCW [4] [5] [7] <br /> EF 52 APRON LEVEL NORTH OF GRID 4.0 PAINT BOOTH 90200 PLUG V-BELT 22,550 5.40 4 1,130 1,800 40 25.4 460 3 60 CARRIER 39 CCW [4] [5] [7] <br /> SCHEDULE NOTES: <br /> (1� STATIC PRESSURE EXTERNAL TO FAN. <br /> [2] MAXIMUM ALLOWABLE MOTOR BRAKEHORSEPOWER AT MAX FLOW AND ESP. <br /> [3J PROVIDE VFD FOR EACH FAN MOTOR, SEE ELECTRICAL DESIGN FOR VFD SPECIFICATIONS, <br /> [4] PROVIDE MANUFACTURER INSTALLED TERMINAL JUNCTION BOX ON EXTERIOR OF UNIT CASING INCLUDING ALL WIRING NECESSARY FOR VFD OPERATION AND CONTROL. PROVIDE ONE JUNCT'ION BOX PER 4 <br /> VFD, <br /> [5] MAXIMUM RADIATED SOUND POWER LEVELS OF THE UNIT SHALL NOT EXCEED 85 dBA. <br /> [6] FANS AND MOTORS SHALL BE SELECTED FOR N+1 REDUNDANCY. <br /> [7] PROVIDE WITH FACTORY INSTALL,ED PIEZOMETER FLOW MEASUREMENT DEVICE FOR EACH FAN WITH PNEUMATIC TUBING ROUTED TO AN EXTERNAL JUNCTION BOX. PROVIDE FIELD INSTALLED <br /> TEMPERATURE <br /> COMPENSATING TRANSDUCERS FOR AIRFLOW MONITORING AND CONNECT TO EXTERNAL JUNCTION BOX. <br /> [8]VALUE PROVIDED IS BASED ON EACH INDIVIDUAL FAN � <br /> [9] VAL,UE PROVIDED IS BASED ON EACH INDIVIDUAL MOTOR <br /> P2P TRENCH FILTER SCHEDULE - PAINTIPREP BOOTH #2 <br /> DESIGN FACE INDIVIDUAL FILTER DIMENSIONS FILTER ARRAY BASIS OF DESIGN <br /> TEMPERATURE VELOCITY <br /> MARK EFFICIENCY (°F) (FPMj HEIGHT(IN} WIDTH (IN) DEPTH (IN) HEIGHT WIDTH TOTAL MANUFACTURER MODEL NOTES <br /> F-1 MERV 14 160 120 24" 24" 4" 3 4 12 PUROLATOR SUPERSORB III [1] [2] [3] <br /> F-2 MERV 14 140 120 24° 24" 4" 2 4 8 PUROLATOR SUPERSORB III [1] [2] [3] � <br /> F-3 99% 140 300 24" 24" 11 1/2° 2 4 8 PUROLATOR ULTRA-CELL LR [4] <br /> F-4 99.97% 160 300 24" 24° 11 1/2" 3 4 12 PUROLATOR ULTRA-CELL HIGH CAPACITY [4] <br /> SCHEDULE NOTES: <br /> [1] PROVIDE SNAPPER BAR ASSEMBLY AT FILTER ARRAY <br /> [2] PROVIDE PAINT ARRESTOR UPSTREAM OF FILTER ARRAY AND MOUNT WITH SNAPPER BAR <br /> [3] DIRTY FILTER PRESSURE DROP EQUAL T01.75" W.C. <br /> [4] DIRTY FILTER PRESSURE DROP EQUAL TO 2.70" W.C. <br /> � <br /> 900 SW 16th Street Suite 307 FSi consulting engineers <br /> Renton, Washington 98057 Solutions & Service <br /> � . <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE �" <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY NHECKED OHIQH/�7 PROCESS EQUIPMENT SCHEDULE 4 OS/OH/�7 O <br /> W2548317 N <br /> 0 Issue For Construction FSi BSC 03/08/16 �� W• C,q� THIS DESIGN AND/OR RED 08/08/17 SHEET � <br /> Q2���,��,�"u�i,,�f SPECIFICATION IS APPROVED ENGINEER TITLE � <br /> 1 Revision-Release 45 FSi BSC 06l14/16 �0�,��� � y o Boein 777X CWC BUILDING <br /> � APPROVED BY DEPT. DATE gSC 08/08/17 g n n N <br /> CHECKED '`/'�X� C <br /> 2 Revision-Release 47 FSi BSC O7l12/16 qP 4ezeo � Y � <br /> ���s c �,�� APPROVED B U I LD I N G 40-58 <br /> 3 Revision-Release 55 FSi BSC 11/01116 S`o"�� E" RED �oe Na coMP Na .� <br /> 40-58-M2xa ¢ <br /> 4 Revision-Release 72(Phase II-PHP) FSi AWL 08/08/17 APPRovE� DWG NO. <br /> osios��7 I MECHANICAL MASTER EVERETT, WA 40-58-M2xa <br />