Laserfiche WebLink
°� _ __ <br /> EXTERIOR INTERIOR 1 O <br /> PVC F�SHING MEMBRANE A600-73 <br /> INSULATED-CORE - <br /> BELOVV COPING <br /> METAL WALL PANELS —� PROVIUE ENOUGH POLYISO METAIL COPI�NG <br /> � <br /> PT WOOD NAILER INSULATION TO MAINTAIN <br /> NOTE: NOTE: REQUIRED 42" HEIGHT ABOVE \ SLOPE / CAP <br /> SEALANT TAPE �� FOR SPECIFIC SIZES ON FASTENERS REFER TO FOR SPECIFIC SIZES ON FASTENERS REFER TO WALKING SURFACE. � � <br /> METAL DEFLAGRATION DESIGN DOCUMENTS BY DESIGN DEFLAGRATION DESIGN DOCUMENTS BY DESIGN �� I <br /> PANEL CLIP AND COUNTERFLASHING DYNAMICS. SEE SHEETS S502-50 AND S502-51 DYNAMICS. SEE SHEETS S502-50 AND S502-51 ' <br /> FASTENER — � GAUGE METAL SUPPORTS —I � , . - <br /> \� :�..,'.' ��� � BENT PLATE <br />� PREFINISHED METAL ° '� \� GASKETED FASTENERS I a_ - ; _ I ANGLE <br /> BASE TRIM � R E C E I V E R T R I M � SELF-DRIl.LING, SELF- PVC ROOF PARAPET FLASHING �- � <br /> SELF-DRILLING, SELF- . - - �� <br /> \\ � MANUFACTURED RIVET @ 12" O.C. TAPPING FASTENER WITH TAPPING FASTENER @ 12° TO EXTEND OVER TOP OF _ - - . <br /> � INSULATED CURB p.C, PARAPET AND SECURELY ; ;, �. ��� J CONTINUOUS <br /> DUST COVER BOND WASHER. EDGE COVER FASTEN TO EXTERIOR WALL - -''�� CLEAT <br /> CONT SEALANT i o RELOCATE SAG FACE - . _ � �: <br /> SUPPORT ZEE SET BASE TRIM IN -,,a� ,�a_ ._ <br /> PVC FLASHING ,, � - I URETHANE SEALANT ROD ATTACHMENT � (� RIVET @ 12"O.C. CONCRETE TO BE CLEAN AND - ' °�� <br /> BONDING ADHESIVE ��, I FASTENER WITH � SMOOTH AND READY FOR " � . 18 GA. GALV. CAP <br /> � WASHER. EDGE C OVER �_ : . � <br /> F A S T E N E R A N D P L A T E — � I RIVET 12" O.C. � ADHERENCE OF ROOFING ' a i' .� a a,-. � UNDER FLASHING <br /> @ -. PVC FLASHING <br /> CONCRETE RIVET � � � MEMBRANE BELOW °'� <br /> P V C R O O F M E M B R A N E i @ 12" O.C. CLEAT. SECURE TO CONCRETE BASE TRIM PVC ROOF PARAPET FLASHING - _ � a'.,_. � o C O P I N G i 8�o T.O. P A R A P E T <br /> � <br />� W I T H C O N C R E T E R I V E T S @ 1 2 1 2 G A. S U P P O R T � � � - � � 42"ABOVE ROOF <br /> I - �Q,� ° " � O.C. CHANNEL �" CLOSURE TRIM METAL BATTEN STRIP ' . � : '-_ o <br /> — — — —� - 12 GA. SUPPORT ; - 4." ° ° I��, a ! @ �� @ 24"O.C.(TYP) ��.�°�� " ° '- <br /> � _ � o � <br /> ° CHANNEL ' � � N RIVET 12 O.C. . -. � #12 TEK SCREWS <br /> ' ° ,° �' ` ° Q � a _ _a-� 4 .`�� � ° : .° PVC FLASHING FASTENER WITH T r PVC ROOF PARAPET �.. _a v�. � @ 8" O.C. #12 TEK SCREWS <br /> � i a ° ' -' � �° � a, � " - �a :.� WASHER. � — SEALANT OR FLASHING HOT AIR WELDED f � -=°� � �� � @ 8"O.C. <br /> ' ' 'a � 12"WIDE CONC. _— BONDING ADHESIVE TAPE SEALANT TAPE AT BASE OF PARAPET(TYP) ; , '_. PREFINISHED <br /> RIGID °� ° ° a < � , ° CURB. SEE - � °. � = a- . �"� .. •. . <br /> INSULATION �, ; � °a �� 4� � a ' ° STRUCTURAL 4 � °-° � a - �-= - "- POLYISO INSULATION � METAL COPING � <br /> °. .a�-, � FASTENER AND PLATE DENSDECK - °� -�a � CAP <br /> ' d � <br /> a Qa� , � � v ' � - Q , ° '° -"� � ° a - � PVC ROOF MEMBRANE SUPPORT ZEE �', SELF-DRILLING, SELF- COVERBOARD � � <br /> ° , - ��a - ; �a - - � HILTI KWIK BOLT II @ 24° a -.: .9 �.- � ; � " , °_. ' - , TAPPING FASTENER WITH ,� ;< �_� �=, 3/16" <br /> � � O.C. - a f , CONTINUOUS BEAD BONDED WASHER. RIGID INSULATION ` � GASKETED CONTINUOUS <br /> � a a a �a ' Q ' d 4 � ° �' a �a a - a� -/ --°1. '- a ' - BUTYL SEALANT. MARRY , - - .. - , BENT PLATE <br /> �4 a1 a _ .d . . , _ - - a . ' • . <br /> ' Q � � ° ' ' � � ' � - �`' a� ""-'a � °� TAPERED INTO JOINT SEALANT � PVC ROOF MEMBRANE ��,..,< ._-, . FASTENERS (A36 STEEL) <br /> . a <br /> ._� <br />'� -`°°a � . a� � . . ' a, �:a ; atr ; ' e� a a a , �, � � ° da ' ° d� CONTINUOUS BEAD BUTYL - ° °°.� - .�4a - °. 9 � _ INSULATION ,� j ��. �� , _ . � , , :°� " - - . <br /> -, . . e .-a -a..��`a� - a �- , ; . : - , ° _° _ °� ad a , , , _ ° SEALANT: MARRY WTO �� Q -_ a� ° a �,ac a .; °, - _ SLOPE: 3/8 .12, � - ; ; ;a � '. ,9,�, <' .. , 1/2"0 POWERS <br /> . , a . a ; _�, , , ; g� , a <, , . - a , a- GALV. CABLE WITH I STAINLESS STEEL BOLT � - ,�-�---.°a-. , . . - - . "WEDGE-BOLT" <br /> La%.d.' , . a,a� Q a , ,� JOINT SEALANT _ _ . . - - � a� - EYELET & BOLTS (TWO I WITH TWO WASHER I I � .- , - _ a - ' „ <br /> a. � - ' a ' a , , PVC ROOF P _.�, @ 12 O.C. (OR <br /> � - v ° , _ �� _ ,�' , , VAPOR RETARDER (2) PER MODULE �` � : PARAPET FLASHING 3��'a= , - 3" � a� APPROVED <br /> . <,.. ; : a. „ _ � a� - , ��-,- "�� _ I '.' : G4 „ <br /> VAPOR RETARDER a � �/�? " " "� �Q � a-?- a�� a � � OVER 1/2" DENSDECK � �. �� °_, TO EXTEND OVER -. a� � , EQUAL) <br /> OVER 1/2" DENSDECK �����- ' � -� _ .. _ TOP OF PARAPET I : ,° ° � � , <br /> ", a a � �- AND SECURELY . � � °� � �' -' , -e - <br /> � - _ - - . , : -. <br /> � : -°,�� .':; FASTEN TO �_ � : = a-: , �a .- ,g: <br /> P2P — ROOF TO IMP DTL � P2P — DEFLEGRATION CURB DTL �s3 P2P — DEFLEGRATION HEAD DTL LH3 - -�� - - . EXTER�oRWA�� _� ;-, �.�a,,�a :�a ��_,.: - CONTINUOUS <br /> ���- FACE � ° <br /> SCALE: 3"= 1'-0" A600-2c A600-73 SCALE: 1 1/2" = 1'-0" `�� � � ' a p <br /> A600-2c A600-73 SCALE: 1 1/2" = 1'-0" METAL ROOF DECK � � " e ��. _ _ �. < - � . <br /> A600-24 A600-73 . - . <br /> �� ��.= = . . . ,_" <br /> VAPOR RETARDER <br /> OVER DENSDECK <br />� <br /> P2 P — PARAP ET P2 P — PARAP ET CAP <br /> NOTE: NOTE: FASTENER WITH NOTE: D ETAI L 8 D ETAI L �O <br /> FOR SPECIFIC SIZES ON FASTENERS REFER TC1 FOR SPECIFIC SIZES ON FASTENERS REFER TO <br /> FOR SPECIFIC SIZES ON FASTENERS REFER TO DEFLAGRATION DESIGN DOCUMENTS BY DESIGN EXA-76 WASHER SCALE: 1 1!2" = 1'-0" A600-2c A600-73 SCALE: 3"= 1'-0" A600-73 A600-73 <br /> DEFLAGRATION DESIGN DOCUMENTS BY DESIGN DEFLAGRATION DESIGN DOCUMENTS BY DESIGN <br /> DYNAMiCS. SEE SHEETS S502-50 AND S502-51 3 DYNAMICS. SEE SHEETS S502-50 AND S502-51 DYNAMICS, SEE SHEETS S502-50 AND S502-51 <br /> A600-73 A600-73 <br /> TEMPORARY FASTENER WITH <br /> FASTENER (TYP.) WASHER <br />� LJ3 2'-11318" ----- - - 3l4" <br /> A600-73 A600-73 318° � -"j---�"- <br /> ,; . <br /> T-- � - - - - - - - - - <br /> �" — — — STEEL COLUMN. <br /> 51/2" 1'-0" 1'-0" 61(4° SEE STRUCTURAL � <br /> ( SEALANT�R 2" CF42 � SEALANT OR �1 G3 - <br /> _ ___ � ' � ' m SEALANT TAPE SEALANT TAPE - <br /> m I � c=� � ° � RIVETS @ INSULATED CONCRETE BASE. � _ <br /> _ � ' ' 2" CF42 INSULATED '(' ' � �° ' �°- n _ - SUPPORTS PANE�S BY RIVETS @ SEE sTRUCTURA� PLA FORM LEVEL <br /> `- v ; �� "_ ° e'z 3�4 I PANELS BY METL-SPAIV I w . � _ , , � . °" "° METL-SPAN � SUPPORTS — � — �� �OO' - 10 1/8�� <br /> � . • <br /> . .� . a -- . � , , Q °' a � °� . ., � CAP TRIM - - E 13" � 13° <br /> � CAP TRIM 2 1/2° C H M TAL STUD ` <br /> � '`� ° �.�. , ..� ' . �, WITH (3) 5/8" GYP. BD. ONE � <br /> � �� � �a Q- , � � � ¢ - . '° : 4 ° °a, _ I SIDE, (�) ��� GYP. BD. LINER - - <br /> - - � " a a - PANEL OPPOSITE SIDE - <br /> �:, � <br /> � �y <br /> SEALANT& ' ' , � � .� . _ _a - ; _ . . � .-. . � _, . _- _ �� <br /> ` CONCRETE BASE. ` <br />� —� - -- � 1 ° d . � . � :� .- � - . `: �- . � _ - <br /> BACKER ROD � - -- SEE STRUCTURAL _ _ , , . , _ . <br /> '. 4 <br /> � a ._ o . . . - <br /> � �°- LEVEL 1 <br /> � � � � CAP TRIM � J. . ° j ��. ,, ° - � � ° � �, - 100� - Q�� <br /> 6 3l8" 8 318" 8 3/8" 8 31$° ( SEALANT& � � a . a3. Q <br /> B A C K E R R O D S E A L A N T O R � S E L F-D R I L L I N G S E L F- SEALANT OR �2; S E A L A N T A N D B A C K E R R O D ° ` �� - A' � a � <br /> 112"� �_ �� � 114° � ' � - , � _ ' � � . - . <br /> 2 11314 ' SEALANT TAPE Q �, � . ° �,. . , � <br /> __ J _a � _ : _� - - �� . . s � � <br /> SEALANT TAPE T A P P I N G F A S T E N E R W I T H d�' " a ' - < : , ; a <br /> , a � <br /> -—-—-— - RNETS 8 BONDED WASHER @ �� °- � " :�. . - . . : - : <br /> 3'-01l2" @ �� RIVETS 8 , - �' . . - ;a"._a; - ^ . - <br /> O.C. <br /> O.C. � <br /> P2P — DEFLEGRATION VENT �APTRIM P2P — DEFLEGRATION VENT <br /> ENLARGED PLAN 2 P2P — DEFLEGRATION VENT JAMB DTL LJ3 VERTICAL JNT DTL 3 P2P — 3HR COLUMN WRAP DTL 9 <br /> SCALE: 1 112"= 1'-0" A600-73 SCALE: 3" = 1'-0° A600-24 A600-73 SCALE: 3" = 1'-0" A600-24 A600-73 SCALE: 1 1/2" = 1'-0" A600-7 A600-73 . <br />� <br /> BOOTH EXTERIOR <br /> BOOTH INTERIOR BOOTH EXTERIOR <br /> SILL GIRT BEYOND , SECURE BOTH FRAMES <br /> PER STRUCTURAL INTO STEEL PLATE W/ ! �� i 60 MINUTE FIRE RATED 7/8" <br /> � � HARDWARE FROM ;� � � �� PILKINGTON PYROSTOP PER BOOTH INTERIOR � <br /> BOOTH INTERIOR BOOTH EXTERIOR WINDOW <br /> !��' � ASTM1191 UL263 IN TGP <br /> MANUFACTURER �;i � <br /> i ;I�•-; ALUM. SERIES FRAME SILICONE SETTWG PAD <br /> 4"THERMALSAFE METAL PANEL —� HEADER, SEE STRUCT FOR \ �i! <br /> �� SILL GIRT, PER STRUCTURAL. � __ i�; <br /> SIZE AND LOCATION JAMB GIRT , SEE STRUCTURAL ANCHOR BOLT REFER TO ELEVATIONS FOR SECURE BOTH FRAMES INTO �-- <br /> BENT PLATE. SEE STRUCTURAL � FOR SIZE AND LOCATION LOCATIONS ! <br />� ANCHOR-BOLT � \ FROM W NDOW MA U�FACTURER <br /> �� THERMALSAFE METAL I ' <br /> THERMALSAFE METAL PANEL \\ 4"THERMALSAFE � PANEL EDGE TRIM, 60 MIN. FIRE RATED 7/8" <br /> EDGE TRIM, PER MANUFACTURER METAL PANEL PER MANUFACTURER PILKINGTON PYROSTOP <br /> SECURE BOTH FRAMES INTO _ BENT PLAT. SEE <br /> STEEL PLATE W/HARDWARE � '` STRUCTURAL <br /> FROM WINDOW MANUFACTURER —� ;I�' ( 4"THERMA�SAFE <br /> Ij I �a '- METAL PANEL <br /> 60 MIN. FIRE RATED 7/8° ;; BOOTH INTERIOR P�P — BOOTH WI N D4W ' <br /> PILKINGTON PYROSTOP. PER !'; BENT PLATE. SEE STRUCTURAL <br /> ASTM E119/UL263 IN TGP ALUM. ;; <br /> SERIES FRAME �� THERMALSAFE METAL PANEL <br /> EDGETRIM, PERMANUFACTURER NOTE: INTERMEDIATE SECTION 7 <br /> TYPE FG-3 GLAZING <br />� SECURE BOTH FRAMES INTO /� REFER TO DETAIL 7/A600-72 FOR SCALE: 1 1/2" = 1'-0" A600-73 <br /> NOTE: STEEL PLATE W/HARDWARE y' COMPLETE GLAZING TYPES � <br /> TYPE FG-3 GLAZING FROM WINDOW MANUFACTURER F O R R E F E R E N C E O N LY <br /> REFER TO DETAIL 7/A600-72 FOR 60 MINUTE FIRE RATED 7/8° NOTE: ���3� <br /> COMPLETE GLAZING TYPES LI. PILKINGTON PYROSTOP. PER FG-3 GLAZING <br /> REGISTERED <br /> ASTM E119/UL263 IN TGP ALUM. REFER TO DETAIL 7/A600-72 FOR ARc��T�cT , , <br /> COMPLETE GLAZING TYPES PETF�,.,�� ,,ARS, 0 0 � 1/2' 1 1 1/2 2' , <br /> SERIES FRAME � <br /> www.brph.com Copyright o 2017 � SCALE: 1 1/2"= 1'-0° <br /> P2 P — 60 M I N W I N DOW - H EAD 4 P2 P — 60 M I N W I N DOW — JAM B 5 P2 P — 60 M I N WI N DOW — S I LL 6 Architects, Engineers, Constructors ^-� � . ���K�r���� �,� <br /> STATE OF WASHING 0�1 �� �� � <br /> SCALE: 1 1!2" = 1'-0" AT AREAS NOT SUBJECT TO HIGH HEAT ° s�ateotwasNn�ton 0 3 6 9" 12' <br /> A600-72 A600-73 SCALE: 1 1/2 = 1'-0" AT AREAS NOT SUBJECT TO HIGH HEAT A600-72 A600-73 SCALE: 1 1/2"= 1'-0" 1902033rdAveW,suitesso CertificateofAulhaizaGon � <br /> AT AREAS NOT SUBJECT TO HIGH HEAT A600-72 A600-73 �ynnwood,washington.98o3o Architectureho,fiO3?35512 <br /> azs�zti-3s�° Engfieenng No.3137 SCALE: 3"= 1'-0" <br /> � <br /> DRAWN DATE SUBTITLE CURRENT REVIS�ON SYMBOL DATE <br />� SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE c <br /> oF wAsy� ACCEPTABILITY CXJ 08/23/16 �r <br /> 0 ISSUEFORCONSTRUCTION �X� PJL 03I08116 ,�P�' �N�o THISDESIGNAND/OR �HE�KEo - P2P PAINT OPERATIONS - DETAILS W2548317 4 os123116 � <br /> 5 2 SPECIFICATION IS APPROVED P�L 08/23116 SHEET n <br /> 1 REVISION-RELEASE 42 CXJ PJL 05I03116 O BRPHARCHIiECTS EN�wEER -Tir�E � <br /> �OE��� EN�inEeRsiNc. APPROVED BY DEPT, DATE PJL 08123116 BOEING 777X CWC BUILDING � <br /> No.a13� CHECKED A6 0 0 7 3 « <br /> 2 REVISION-RELEASE 43 CXJ PJL 05/17116 d <br /> � BUILDING40-58 <br /> 3 REVISION-RELEASE 50 CXJ PJL 08/23/16 m�,� �o APPRovE� �oB No. connP rvo. �; � <br /> ��qr o��tiP 40-58-A600-73 � <br /> 4 REVISION-RELEASE 72(PHASE II-PHP) CAJ PJL os�osr�� F oF A�jN APPROVED ARCHITECTURAL MASTER EVERETT, WA ow�No. 40-58-A600-73 <br />