My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2017 BLDG 40-58 Plans 2022-11-09
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD 2017 BLDG 40-58 Plans 2022-11-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 10:28:04 AM
Creation date
6/17/2019 10:00:42 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
B1708-033
Year
2017
Notes
PAINT BOOTHS 3 AND 4
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
247
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br /> � I ■ I ■ ' ■ I ■ 1 HOUR FIRE BARRIER <br /> K.75 26 GAUGE MIN. DUCT BEYOND � <br /> RATED FOR 1 HOUR FIRE i � � � � � � � � <br /> BARRIER-SEE MECHANICAL / <br /> % TYPICAL NOTE: TO CONFORM TO THE <br /> WEST MIDDLE BAY ' WEST MIDDLE BAY EAST MIDDLE BAY REQUIREMENTS OF THE ASTM E-119 FIRE <br /> SPRINKLER. SEE / WEST MIDDLE BAY RESISTANCE RATING, THE FILLER INSULATION <br /> I FIRE ; MUST HAVE AN APPROVED CLASSIFICATION <br /> PROTECTION -- MARKING FOR SURFACE BURNING <br /> (TYP.) CHARACTERISTICS OR FIRE RESISTANCE <br /> FILL JOINT BETWEEN STEEL '�� 26 GAUGE MIN. DUCT RATED 26 GAUGE MIN. DUCT RATED <br /> I AND EDGE FLASHING WITH , ` FOR 1 HOUR FIRE BARRIER- FOR 1 HOUR FIRE BARRIER - <br /> , MINERAL WOOL FIBER FILLER — 1-1/2" METAL DECK I 1-1/2 METAL DECK � „ SEE MECHANICAL 1-1/2" METAL DECK --- SEE MECHANICAL <br /> �� COMPLIANT WITH ASTM E-119 �, � LEVEL M2 1-1/2 METAL LEVEL M2 � LEVEL M2 <br /> AND SEAL EXPOSED EDGE - - - - - - - - - - � DECK_ _ � _ _ � _ _ _ ___ __ __ _ _ _ _ _ � <br /> WITH FIRE CAULK � 133' - 4" 133' - 4" 133' - 4" <br /> ,, <br /> � NON-CONTINUOUS <br /> NON-CONTINUOUS RAFTERS SPAN BETWEEN STEEL FLOOR <br /> � CONTINUOUS PAINT SUPPORT. SEE <br /> RAFTERS SPAN / <br /> BETWEEN CONTINUOUS ROOM RAFTERS STRUCTURAL <br /> PAINT ROOM RAFTERS — FILL JOINT BETWEEN STEEL AND <br /> NOTE: FASTENER PATTERN TO BE EDGE FLASHING WITH MINERAL <br /> DETERMINED PER SPECIFIC PROJECT I CONTINUOUS RAFTERS ' WOOL FIBER FILLER COMPLIANT <br /> ' �. MANUFACTURER REQUIREMENTS � SPAN BETWEEN EAST I WITH ASTM E-119 AND SEAL �— CONTINUOUS RAFTERS <br /> EXPOSED EDGE WITH FIRE CAULK SPAN BETWEEN EAST <br /> � SIM `\ AND WEST PAINT ROOM � AND WEST PAINT ROOM <br /> 4 4" INSULATED COLUMNS BEYOND / <br /> �� A600 4 A600-72 � � � � BENT METAL TO MATCH MECH. � , COLUMNS (BEYOND) <br /> METAL PANEL <br /> '� �'�. � I 4" INSULATED DUCTWORK MATERIAL AND ' 4" INSULATED � <br /> \, METAL PANEL � GAUGE BOTH SIDES. 26 GA. MIN. ; METAL PANEL <br /> _ � % \ �� (TYP.) -- - % <br /> . ,< , <br /> � <br /> % , � � � <br /> ---- --- - - - <br /> , - - - -- - -- - - -_ _ <br /> � � � � <br /> � � t a � iil ii <br /> � . � ���. <br /> � � � _ �. <br /> �� ���� <br /> �k�'�I t �'�VHI,�'�kk�e. <br /> } +V: <br /> 51 � <br /> — — o /. I _ _ — ._ —___— — _ <br /> � i <br /> � <br /> ,, � � � � �� � � <br /> ,� � � <br /> ';� �I � ��� �- FIRE CAULK PLATES BETWEEN � - FASTEN DUCT SHEET METAL <br /> 1 '� BENT METAL TO MATCH MECH. BETWEEN METAL PANEL END <br /> � � STRUCTURAL STEEL � 1 1 FIRE CAULK PLATES BETWEEN <br /> 4" INSULATED � �� � �� DUCTWORK MATERIAL AND GAUG� ; STRUCTURAL STEEL BOTH <br /> \ BENT METAL TO MATCH MECH. CLOSURE. FIRE CAULK AT ALL <br /> METAL PANEL = I BOTH SIDES. 26 GA. MIN. (TYP.) SIDES OF BOX BEAM TYP.) IMP/DUCT JOtNTS. <br /> . � DUCTWORK MATERIAL AND � � ` I � <br /> FIRE CAULK PLATES ' i �, GAUGE BOTH SIDES. 26 GA. MIN. FIRE CAULK PLATES '- FIRE CAULK PLATES BETWEEN FIRE CAULK PLATES BETWEEN <br /> BETWEEN ��� � (TYP.) � BETWEEN I STRUCTURAL STEEL BOTH FIRE CAULK STRUCTURAL STEEL <br /> STRUCTURAL STEEL - -� �- FIRE CAULK PLATES BETWEEN STRUCTURAL STEEL � SIDES (TYP.) PLATE B T N <br /> S E WEE <br /> STRUCTURALSTEEL STRUCTURAL <br /> STEEL - <br /> P2P CEILING DETAIL AT CENTER P2P CEILING DETAIL AT OUTER EDGE <br /> P2P CEILING AT WEST END � MONORAIL 2 OF DUCT/IMP � o <br /> SCALE: 1 1/2"= 1'-0" A600-30 A600-74 � SCALE: 1 1/2"= 1'-0" A600-30 A600-74 SCALE: 1 1/2" = 1'-0" A600-30 A600-74 <br /> A600-74 A600-74 <br /> 3.50 SOUTH MIDDLE BAY NORTH MIDDLE BAY <br /> EQUIPMENT ROOM PLATFORM <br /> 26 GAUGE MIN. DUCT RATED <br /> FOR 1 HOUR FIRE BARRIER - � <br /> � SEE MECHANICAL ��� CONCRETE SLAB <br /> �- 1-1/2" METAL DECK �� � 26 GAUGE MIN. DUCT RATED ON METAL DECK <br /> \'�, �-1/2" METAL %� FOR 1 HOUR FIRE BARRIER - ,= 1-1/2" METAL DECK � <br /> _ _ _ _ _ LEVEL M2fE� _ _ _ SEE MECHANICAL-L M_2 _� <br /> 133' -4" �1 <br /> 133' - 4" �1 <br /> � � LEVEL M2 <br /> - — ---- - - -- — — --- - — - — -- - - 133' - 4"� <br /> CONTINUOUS RAFTERS FILL JOINT BETWEEN STEEL AND METAL STUD WALL WITH y`� <br /> I SPAN BETWEEN EAST EDGE FLASHING WITH MINERAL � <br /> ROOM COLUMNS ; PLAN BOR EXTE�NTS OF ��` _�, CONT <br /> - - - - - - - - - - - - - - WOOL FIBER FILLER COMPLIANT I <br /> ! WITH ASTM E-119 AND SEAL � WALL BETWEEN PAINT ROL ROOM <br /> ___ <br /> ', - - - _ EXPOSED EDGE WITH FIRE CAULK — AND PREP ROOMS - ;z_ - II <br /> � - - - --- ----- - ��,� ��`� � <br /> � �, � �� , �. SPACE ABOVE �,'- � , / <br /> ' PAINT/PREP ROOM �` / <br /> � - � , , „ � <br />