My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2714 COLBY AVE ROMIOS PIZZA 2019-06-24
>
Address Records
>
COLBY AVE
>
2714
>
ROMIOS PIZZA
>
2714 COLBY AVE ROMIOS PIZZA 2019-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2019 9:57:14 AM
Creation date
6/24/2019 9:57:05 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2714
Tenant Name
ROMIOS PIZZA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> 5. A commercial kitchen plumbing permit application is required. <br /> Type I Hood (Deferred Submittal) <br /> 1. Please have your contractor submit the required documents and drawings listed in the <br /> attached commercial hood checklist prior as part of the permit application: <br /> https://everettwa.gov/DocumentCenter/HonneNiew/115 <br /> 2. The details behind the Type I hood, a section and the other information summarized on <br /> the attached commercial mechanical submittal checklist and worksheet should be shown <br /> on the drawings and submitted in a deferred hood (Type I and II) mechanical permit <br /> application. The completed worksheet is should be included as part of the submittal. <br /> 3. A rated Type I Hood duct enclosure is required from the point of penetration of the <br /> floor-ceiling assembly to the outlet terminal, per IMC section 506.3.10. Catalog cuts of <br /> the rated enclosure material and installation requirements classified in accordance with <br /> ASTM E 814 should be submitted with the drawings. The start and termination of the <br /> grease duct fire wrap for the Type I hood ducts should be shown on building sections to <br /> extend from the Type I hoods to the outlet terminal, per IMC Section 506.3.10.2. <br /> a. For zero clearance to combustible roof construction, the listed assembly for the <br /> grease duct enclosure system of one hour fire resistant duct fire wrap (two layers) <br /> should be shown to meet the requirements of ASTM E 2336, per IMC section <br /> 506.3.6, exception 3. <br /> b. 18 inches of clearance is required from the combustible roof assembly, unless the <br /> listed assembly of one hour fire resistant duct wrap is shown on the drawings. Note <br /> that an enclosed rated duct enclosure is not required where penetrating a non-rated <br /> roof-ceiling assembly, per IMC section 506.3.11.4. The Type I hood duct enclosure <br /> currently shown on the drawings does not meet the reduction requirements for zero <br /> clearance to combustible construction. <br /> 4. Where the kitchen ceiling abuts the Type I hood, 18 inches (currently 12 inches is <br /> shown) of a smooth, cleanable, nonabsorbent and noncombustible material should be <br /> shown on the drawings between the hood and the ceiling material, per the exception to <br /> IMC section 507.9. <br /> 5. The elevation should be dimension the smooth, cleanable, nonabsorbent and <br /> noncombustible material, shown on the drawings. This wall covering should be noted to <br /> extend 18 inches in all directions from the hood to the full height of the hood canopy, <br /> per the exception to IMC section 507.9. <br /> 6. The inside lower edges of the Type I commercial hoods should be dimensioned on the <br /> drawings to extend minimum 6 inches beyond the edge of the top horizontal surface of i ;', <br /> the appliance on all open sides, unless the hood is closed to the appliance side by a <br /> noncombustible wall or panel meeting the requirements of the exception to IMC section <br /> 507.9, specifically on the hood returns adjacent to wall construction. <br /> 7. The exterior exhaust fan(s) should be shown in section on the drawings to have an <br /> approved drain outlet at the lowest point of the housing to permit drainage of grease to <br /> an approved grease reservoir, per IMC section 506.5.2. This detail should be ref renced - <br /> on the sections on sheets M5 and M6. <br /> CITY OF EVERETT PERMIT SERVICES 3200 CEDAR ST, EVERETT, WA 98201 425-257-8810 <br /> website: www.everettwa.qov/permit January 24, 2017 email: everetteps a@.everettwa.pov <br />
The URL can be used to link to this page
Your browser does not support the video tag.