Laserfiche WebLink
12.When splashguards (partitions and/or walls) are provided on both sides of a handwash sink the <br /> distance between the splashguards must be at least 18 inches apart (shoulder width) to allow <br /> proper access to the handwash sink. <br /> 13. All handwash sinks basins must be at'least 10" long by 10" wide and 5" deep. Ensure that all <br /> handwash sink basins are at least 10"x10"x5". <br /> 14. Water heaters must be of sufficient size to provide hot water to dishwasher and/or scullery sinks <br /> and at the same time provide hot water to all handwash sinks. <br /> 15. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility <br /> must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational <br /> inspection. This is required so that proper testing of the 15-second time requirement for hot water <br /> availability can be completed. <br /> 16. All food service equipment, both new and used, must be listed by the National Sanitation <br /> Foundation (NSF) or equivalent for its intended use. Used and new refrigeration must be capable of <br /> holding food at temperature of 41°F or below. <br /> 17. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed <br /> food service establishment. Used equipment must be clean, in proper operating condition, and in <br /> good repair. Used refrigeration must be capable of holding ata temperature of 41°F or below. <br /> 18. No model numbers were submitted for either the three compartment sink or the food preparation <br /> sinks. Prior to the request for a pre-operational inspection submit complete manufacturer name and <br /> model numbers for both the three compartment sink and the food preparations sinks. All food <br /> service equipment must be commercial NSF or equivalent listed. Equipment found not to be <br /> commercial NSF or equivalent listed at the time of the pre-operational inspection will be required to <br /> be removed and replaced with commercial NSF or equivalent listed equipment. <br /> 19. Extra wall protection is required on walls behind all sinks, including restroom handwash sinks, and <br /> food preparation counters and tables. Sinks in corners must also have wall protection on the side <br /> walls. A 16-inch high backsplash of plastic laminate, fiberglass-reinforced plastic or equal is <br /> acceptable. A backsplash higher than 16 inches is required on the wall behind counter top <br /> equipment taller than 16 inches. Floor to ceiling protection is required on the wall behind <br /> dishwashers. Wall protection behind mop sinks must cover the entire splash zone. Plastic coated <br /> hardboard is not acceptable. <br /> 20.All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must <br /> be surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw <br /> cuts and the like in concrete floors in all areas, including customer seating areas, must be filled and <br /> sealed so as to provide a smooth and cleanable surface. <br /> 21. The ceiling above the food preparation areas must be non-perforated, nonabsorbent, smooth and <br /> easily cleanable. <br /> 22. Cabinet shelving must be nonabsorbent, smooth and easily cleanable. (Self stick vinyl or other type <br /> surfaces are not acceptable) <br /> 23.All light fixtures in food preparation and storage areas must be provided with covers and <br /> shatterproof bulbs. Hot hold unit heat lamps must be provided with shatterproof bulbs. <br /> 24. Plumbing must meet state and local codes. <br /> 25. It cannot be determined from the floor plan or information submitted whether or not a chemical <br /> dispensing system will be installed at the mop sink. Please note that the use of screw-on type `wye' <br /> adaptors at the mop sink faucet for use with chemical dispensing systems is prohibited. <br /> Additionally chemical dispensers cannot be connected to the mop sink faucet. The chemical <br /> dispenser must have a separate water connection. A `sidekick' adaptor at the mop sink faucet is <br /> acceptable. <br /> 26. The ventilation system shall be installed and operated to meet applicable building, mechanical, and <br /> fire codes. <br />