My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6002 COMMERCIAL AVE 2019-06-24
>
Address Records
>
COMMERCIAL AVE
>
6002
>
6002 COMMERCIAL AVE 2019-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2019 11:04:44 AM
Creation date
6/24/2019 11:04:33 AM
Metadata
Fields
Template:
Address Document
Street Name
COMMERCIAL AVE
Street Number
6002
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ALL PROPOSED ALTERNATE TYPICAL DETAILS TO THOSE PROVIDED WITH RELATED <br /> CALCULATIONS TO THE ENGINEER FOR APPROVAL PRIOR TO SHOP DRAWING PRODUCTION <br /> AND FIELD USE. <br /> 9. ALL STRUCTURAL SYSTEMS, WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD <br /> ERECTED, SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, <br /> DELIVERY, HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS <br /> PREPARED BY THE SUPPLIER. <br /> GEOTECHNICAL <br /> 10. FOUNDATION NOTES: ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE <br /> ASSUMED AND THEREFORE MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER OR <br /> APPROVED BY THE BUILDING OFFICIAL. IF SOILS ARE FOUND TO BE OTHER THAN <br /> ASSUMED, NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. <br /> FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT <br /> FINISHED GRADE. UNLESS OTHERWISE NOTED, FOOTINGS SHALL BE CENTERED BELOW <br /> COLUMNS OR WALLS ABOVE. <br /> BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND <br /> PROVIDE FOR SUBSURFACE DRAINAGE. <br /> ALLOWABLE SOIL PRESSURE 1500 PSF <br /> RENOVATION <br /> 11. DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE <br /> COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING <br /> CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. <br /> DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING <br /> STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON <br /> EXISTING FLOOR SYSTEMS TO 40 PSF. <br /> 12. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND <br /> CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING <br /> CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND <br /> MUST BE VERIFIED. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND STRUCTURAL <br /> ENGINEER IF EXISTING CONDITIONS DETERMINED DURING WORK VARY FROM THE <br /> EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS. <br /> 13. CONTRACTOR SHALL CHECK FOR DRY ROT AT ALL AREAS OF NEW WORK. ALL ROT <br /> SHALL BE REMOVED AND DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS <br /> DIRECTED BY THE STRUCTURAL ENGINEER OR ARCHITECT. <br /> CONCRETE <br /> 14 . CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE <br /> WITH ACI 301, INCLUDING TESTING PROCEDURES. CONCRETE SHALL ATTAIN A 28-DAY <br /> STRENGTH OF f'c = 3, 000 PSI AND MIX SHALL CONTAIN NOT LESS THAN 5-1/2 <br /> SACKS OF CEMENT PER CUBIC YARD AND SHALL BE PROPORTIONED TO PRODUCE A <br /> SLUMP OF 5" OR LESS. REQUIRED CONCRETE STRENGTH IS BASED ON THE DURABILITY <br /> REQUIREMENTS OF SECTION 1904 OF THE IBC. DESIGN STRENGTH IS f'c = 2, 500 <br /> PSI. <br /> 15. ALL CONCRETE WITH SURFACES EXPOSED TO WEATHER OR STANDING WATER SHALL BE <br /> AIR-ENTRAINED WITH AN AIR-ENTRAINING AGENT CONFORMING TO ASTM C260, C494, <br /> AND C618. TOTAL AIR CONTENT FOR FROST-RESISTANT CONCRETE SHALL BE 1 <br /> ACCORDANCE WITH ACI 318, TABLE 19.3.2.1 MODERATE EXPOSURE, Fl. <br />
The URL can be used to link to this page
Your browser does not support the video tag.