My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6002 COMMERCIAL AVE 2019-06-24
>
Address Records
>
COMMERCIAL AVE
>
6002
>
6002 COMMERCIAL AVE 2019-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2019 11:04:44 AM
Creation date
6/24/2019 11:04:33 AM
Metadata
Fields
Template:
Address Document
Street Name
COMMERCIAL AVE
Street Number
6002
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
16. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1) , <br /> GRADE 60, FY = 60, 000 PSI. EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON <br /> THE DRAWINGS SHALL BE GRADE 40, FY = 40,000 PSI. WELDED WIRE FABRIC SHALL <br /> CONFORM TO ASTM A-185. SPIRAL REINFORCEMENT SHALL BE DEFORMED WIRE <br /> CONFORMING TO ASTM A615, GRADE 60, FY = 60, 000 PSI. <br /> 17. DETAILING OF REINFORCING STEEL (INCLUDING HOOKS AND BENDS) SHALL BE IN <br /> ACCORDANCE WITH ACI 315-99 AND 318-14. LAP ALL CONTINUOUS REINFORCEMENT <br /> #5 AND SMALLER 40 BAR DIAMETERS OR 2'-0" MINIMUM. PROVIDE CORNER BARS AT <br /> ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS #5 AND SMALLER 40 BAR <br /> DIAMETERS OR 2'-0" MINIMUM. LAPS OF LARGER BARS SHALL BE MADE IN <br /> ACCORDANCE WITH ACI 318-14, CLASS B. LAP ADJACENT MATS OF WELDED WIRE <br /> FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. <br /> NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS <br /> SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. <br /> 18. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: <br /> FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED <br /> TO EARTH 3" <br /> FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS OR LARGER) . . . 2" <br /> FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#5 BARS OR SMALLER) . . 1-1/2" <br /> COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1-1/2" <br /> SLABS AND WALLS (INT. FACE) . . . .GREATER OF BAR DIAMETER PLUS 1/8" OR <br /> 3/4" <br /> 19. CAST-IN-PLACE CONCRETE: SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND <br /> DIMENSIONS OF DOOR AND WINDOW OPENINGS IN ALL CONCRETE WALLS. SEE <br /> MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF MISCELLANEOUS MECHANICAL <br /> OPENINGS THROUGH CONCRETE WALLS. SEE ARCHITECTURAL DRAWINGS FOR ALL <br /> GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE, AND OTHER <br /> FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES, BOTH CAST-IN-PLACE AND <br /> PRECAST. <br /> ANCHORAGE <br /> 20. EPDXY-GROUTED ITEMS (THREADED RODS OR REINFORCING BAR) SPECIFIED ON THE <br /> DRAWINGS SHALL BE INSTALLED USING "AT-XP" AS MANUFACTURED BY SIMPSON <br /> STRONG-TIE COMPANY. INSTALL IN STRICT ACCORDANCE WITH IAMPO REPORT NO. ER- <br /> 0281. MINIMUM BASE MATERIAL TEMPERATURE IS 14 DEGREES, F. RODS SHALL BE <br /> ASTM A-36 UNLESS OTHERWISE NOTED. PERIODIC SPECIAL INSPECTION OF <br /> INSTALLATION IS REQUIRED TO VERIFY ANCHOR OR EMBEDED BAR TYPE AND <br /> DIMENSIONS, LOCATION, ADHESIVE IDENTIFICATION AND EXPIRATION, HOLE <br /> DIMENSIONS, HOLE CLEANING PROCEDURE, ANCHOR EMBEDMENT, AND ADHERENCE TO <br /> THE INSTALLATION INSTRUCTIONS. CONTINUOUS SPECIAL INSPECTION IS REQUIRED <br /> FOR HORIZONTAL AND OVERHEAD INSTALLATIONS. <br /> WOOD <br /> 21. FRAMING LUMBER SHALL BE S-DRY, KD, OR MC-19, AND GRADED AND MARKED IN <br /> CONFORMANCE WITH WCLIB STANDARD "GRADING RULES FOR WEST COAST LUMBER NO. <br /> 17", OR WWPA STANDARD, "WESTERN LUMBER GRADING RULES 2011". FURNISH TO <br /> THE FOLLOWING MINIMUM STANDARDS: <br /> JOISTS (2X & 3X MEMBERS) HEM-FIR NO. 2 <br /> AND BEAMS MINIMUM BASE VALUE, Fb = 850 PSI <br /> (4X MEMBERS) DOUGLAS FIR-LARCH NO. 1 <br /> MINIMUM BASE VALUE, Fb = 1000 PSI .„--. <br /> (:/-j141 <br />