My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1502 SE EVERETT MALL WAY FLOOR AND DECOR 2019-06-24
>
Address Records
>
SE EVERETT MALL WAY
>
1502
>
FLOOR AND DECOR
>
1502 SE EVERETT MALL WAY FLOOR AND DECOR 2019-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2019 2:20:09 PM
Creation date
6/24/2019 2:19:44 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1502
Tenant Name
FLOOR AND DECOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
214
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBLIC WORKS' <br /> March 9, 2018 <br /> Stacey Haggerson <br /> Centerpoint Integrated Solutions <br /> 355 Union Boulevard, STE 301 <br /> Lakewood, CO 80228 <br /> shaggerson©centerpoint-is.com <br /> Owner: VOP Associates <br /> Job Address: 1502 SE Everett Mall Way <br /> Plan Check No: B1801-024 <br /> RE: Building Permit Review Letter <br /> Dear Ms. Haggerson, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. <br /> General <br /> 1. The existing building is Type III 1-Hr (A) construction. Type II is not possible due to the <br /> wood GLB columns (and the roof is not completely heavy timber). It is possible that the <br /> building could comply as Type III-B construction — calculations would need to be <br /> supplied. If the building stays as Type III-A, fire-resistive details for the roof/ceilings, <br /> walls and columns should be provided (or heavy timber design). Section 602.3 <br /> 2. The plans should show that special inspection will be provided for the storage racks that <br /> are 8 feet or greater in height. Section 1705.12.7 <br /> 3. Along with the deferred submissions for the sprinkler and fire alarm systems shown on <br /> the cover sheet, an additional, separate permit submission is required for the storage <br /> racks. <br /> 4. The portion of the new exterior pedestrian ramp (Exit C) that is greater than 30 inches <br /> above adjacent grade, or other parts of the ramp should be provided with a guard in <br /> compliance with Section 1015. <br /> 5. The handrails for the new exterior pedestrian ramp (Exit C) should both continue past <br /> the edge of the ramp for a minimum of 12 inches at the lowest landing. Section 1014.6 <br /> 6. The capacity of Exit C is limited by the width of the ramp (5'-4"). The calculations on <br /> Sheet G001 should be revised to show 64" vs 92" (overall exit width still fine however). <br /> Section 1005.3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.