My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1502 SE EVERETT MALL WAY FLOOR AND DECOR 2019-06-24
>
Address Records
>
SE EVERETT MALL WAY
>
1502
>
FLOOR AND DECOR
>
1502 SE EVERETT MALL WAY FLOOR AND DECOR 2019-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2019 2:20:09 PM
Creation date
6/24/2019 2:19:44 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1502
Tenant Name
FLOOR AND DECOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
214
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Structural <br /> 1. It appears that new wall openings are being added to the existing building as well as <br /> new roof framing with a portion of this framing attaching to the existing structure. A <br /> new slab-on-grade is being added for the majority of the building. By inspection, the <br /> proposed work appears to comprise more than 50% of the building area. Per IEBC Sec <br /> 907.4.1, please provide an engineering analysis and evaluation report for seismic forces <br /> acting on the altered structure. <br /> 2. From the submitted permit calculations, it appears that the existing beams labeled G1 <br /> through G4, used a snow loading of 20 psf uniform snow load for evaluation. The <br /> design snow loading is 25 psf uniform non-reducible. Please revise the calculation as <br /> required and provide details for possible strengthening, if required, for gravity framing <br /> members affected by placement of new mechanical units per IEBC Sec 907.3. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two new sets of revised construction documents reflecting the corrections <br /> requested. Please include a response letter which indicates how the corrections were resolved. <br /> All codes cited refer to the 2015 International Building Code (IBC), 2015 International Existing <br /> Building Code (IEBC), the 2015 International Fire Code (IFC), the 2015 International Mechanical <br /> Code (IMC), and/or the 2015 Washington State Energy Code (WSEC), as amended by the State <br /> of Washington and adopted by the City of Everett. The current IBC referenced standard for <br /> accessible design is the 2009 "Accessible and Usable Buildings and Facilities" (ICC/ANSI <br /> A117.1). Federal ADA regulations and standards may be more restrictive. <br /> These comments address building issues only. Additional revisions or additions may be required <br /> by other departments (such as Utilities, Traffic, Planning or Fire). All required submittals must <br /> be of sufficient detail and information to ensure that the proposed structure will be constructed <br /> in compliance with all adopted codes. <br /> Sincerely, <br /> Tony Lee <br /> Building Official <br /> Ja es Bronder, PE <br /> Associate Engineer/ Plans Examiner <br /> (g/")) <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8813 • Page 2 <br />