r <br /> • <br /> 4=i <br /> ENGINEERING <br /> 4.s <br /> PUBLIC SERVICES DEPARTMENT <br /> December 5, 2017 <br /> Marilyn Rosenberg <br /> 2410 Maple St <br /> Everett WA 98201 <br /> RE: Owner: Rosenberg <br /> Job Address: 2410 Maple St <br /> Plan Check Number: CW1710-002 <br /> Dear Ms. Rosenberg, <br /> In response to your application for a construction permit, your plans have been examined and you <br /> are advised that the issuance of a permit is being withheld for the reasons listed below. These <br /> comments address building issues only. Additional revisions or additions may be required by other <br /> departments (such as Utilities, Planning or Fire). All references refer to the 2015 International <br /> Building Code,(IBC) 2015 International Residential Code,(IRC) as amended by the State of <br /> Washington and/or Washington State Energy Code, (WSEC) 2015 Edition, and adopted by the City <br /> of Everett, unless stated otherwise. <br /> In order for the processing of your application to continue, It will be necessary to <br /> provide the Building Division with two new complete sets of drawings reflecting the <br /> corrections requested. The revised drawings shall clearly define the scope of the work <br /> to be done and show how it meets the requirements of all applicable codes. <br /> 1. The construction drawings shall show how the proposed dwelling will meet the minimum <br /> requirements of the Washington State Energy Code. Specify insulation value in all <br /> components and the U-Value of all fenestration. <br /> 2. Rigid insulation is required to extend from the top of the foundation wall to the top of the <br /> footing. If the top of the footing is more than 24 inches below grade, the Insulation Is not <br /> required to extend beyond the minimum 24 inch depth. Show insulation and protective <br /> cover on all section drawings. <br /> 3. Rigid insulation installed above grade is required to be protected from Impact and ex••,. <br /> to ultraviolet light. Please provide detail showing how insulation is protected. <br /> 4. Headers in exterior walls are required to be insulated with minimum R-10 Rigid Insulation <br /> Show requirement In typical wall section (see #9 below). <br /> Provide inch <br /> ldat all i , oo <br /> location df!nd ngs on plans. If landings arecon provide #4 bar dowelled into <br /> existing foundation wall at not more than 18"O.C. Show on plans. <br /> 6. provide roof framing plan show the size, species and grade of all framing lumber, <br /> sheathing,moisture barrier and roofing material In the roof structure. <br /> Page <br /> 3200 Cedar Street• Everett,WA 98201 •(425)257-8810 • Fax(425) <br /> CITY OF i 4lERE1T is ; <br />