NET METER _mass ir <br /> UTILITY/AHJ(PHENOLIC) ,J, ,,,,,„,„:____j i 1 0 \,„ <br /> 0 <br /> I WARNING DUAL POWER SOURCE '_ POWER TO THIS BUILDING IS SUPPLIED FROM THE <br /> SECOND SOURCE IS PHOTOVOLTAIC SYS . \\ <br /> NEC 705.12(6)(3) FOLLOWING SOURCES WITH DISCONNECT LOCATED AS SHOWN <br /> N <br /> PHOTOVOLTAIC ^ A 1 I ' Smart energytodayl' <br /> TURN OFF PHOTOVOLTAIC SOLAR <br /> lal AC DISCONNECT PRIOR TO E <br /> ilu m WORKING INSIDE PANEL W <br /> AC DISCONNECT IN , <br /> NEC 690.13(6) ;um IIjNEC 110.21(6)&NEC 705.12 MI '❑ 'SI► s <br /> �,■ ,■ _ I -I 0 ,1001 COOPER POINT <br /> ;�■ ,�■ A WARM <br /> I■ N■ RD SW.STE 140-290. <br /> • �■ IN SECOND SOURCE IS MOT•a OLYMPIA.WA 98502 <br /> A WARNING ••I■•I ❑ PHONE:360-637-4343 <br /> NEC. . ... (6)(3) <br /> 1111 1 \ <br /> HEIDI PASCHAL <br /> SUPPLY SIDE TAP PROJECT MANAGER <br /> INVERTER OUTPUT CONNECTION.DO I <br /> \ACDISCONNECT PROJECT DETAILS <br /> NOT RELOCATE AS REQUIRED IF PV <br /> THIS OVERCURRENT INTERCONNECTION IS NET PRODUCTION METER S ! 6.300 DC KW <br /> DEVICE. MADE TO SUPPLY SIDE OF f ❑ <br /> 6.000 KW CECC RATING <br /> NEC 705.12(6)(2)(3)(b) SERVICE DISCONNECT <br /> CENTRAL INVERT <br /> R SYSTEM <br /> 23° 270° <br /> PRODUCTION METER PRODUCTION METER AZIMUTH <br /> SERVICED BY QUALIFIED PERSONNEL ONLY CUSTOMER INFO <br /> UTILITY/AHJ(PHENOLIC) I I { NEC 690.53 4706 GLENWOOD AVE <br /> PHOTOVOLTAIC DC DISCONNECT EVERETT, <br /> A WARNING DUAL POWER SOURCE OPERATING VOLTAGE KM= WA 98203 <br /> SECOND SOURCE IS PHOTOVOLTAIC SYSTEM OPERATING CIRCUIT CURRENT WM. <br /> MAXIMUM VOLTAGE �� CHRISTOPHER CONNAIR <br /> I <br /> NEC 705.12(B)(3) MAXIMUM CIRCUIT CURRENT KM. (937)305-581 2 <br /> NEC 690.56 ADHESIVE FASTENED SIGNS: <br /> •THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. <br /> PHOTOVOLTAIC SYSTEM •WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL FIELD APPLIED LABELS,WARNINGS, APN:00505700003905 <br /> SOLAR PV SYSTEM EQUIPPED IAND MARKINGS SHOULD COMPLY WITH ANSI Z535.4[NEC 110.21(B)FIELD MARKING]. <br /> WITH RAPID SHUTDOWN EQUIPPED WITH •ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED.VINYL SIGNS <br /> A fE: RAPIDD SHUTDOWN SHALL BE WEATHER RESISTANT[IFC 605.1 1.1.3] REVISION <br /> TURN RAPID SHUTDOWN IE , DATE DESCRIPTION <br /> �°`"" E�saK <br /> SWITCH TO THE -... ._ NEC 690.31 G 3 & 4 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL.AND LABELED FOR ITS <br /> "OFF POSITION TO ANIVIAINMAY <br /> SHUTDOWN PV SYSTEM iiiIiiid WARNING: PHOTOVOLTAICAPPLICATION. <br /> AND REDUCE 2.) ALL CONDUCTORS SHALL BE COPPER,RATED FOR 600 V AND 90 DEGREE C WET <br /> SHOCK HAZARD <br /> ai RAPIDUTDOWN <br /> ITTCHFOR POWER SOURCEENVIRONMENT. <br /> IN THE ARRAY SOLAR wSYSTEM 3.) WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED <br /> DIRECTLY TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE,HIP, <br /> NEC 690.56(C)(1)(a) OR VALLEY. DATE 4/23/19 <br /> 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT DRAWN: <br /> PHOTOVOLTAIC AC DISCONNECT SHALL COMPLY WITH NEC 110.26. DRAWN BY: PD <br /> MAXIMUM AC OPERATING CURRENT 25.0 A e 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR <br /> MAXIMUM AC OPERATING VOLTAGE 240 VAC SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACCESSORIES SHEET TITLE <br /> TO FULFILL APPLICABLE CODES AND STANDARDS. <br /> NEC 690.54 6.) WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, <br /> THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. LABELING <br /> 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br /> GAWARNIN8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND REQUIREMENT <br /> ELECTRIC SHOCK HAZARD WARNING: PHOTOVOLTAIC <br /> WARNING V RAPID SHUTDOWN NODULE SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S <br /> DO NOT TOUCH TERMINALS SWITCH FOR 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB <br /> TERMINALS ON BOTH LINE AND POWER SOURCE LUG OR ILSCO GBL-4DBT LAY-IN LUG. <br /> LOAD SIDES MAY BE ENERGIZED SOLAR PV SYSTEM 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE SHEET NUMBER <br /> IN THE OPEN POSITION NEC 690.31(G)(3)&(4) <br /> NEC 690.13(6)&NEC 690.115(D) NEC 690.56(C)(3) SYSTEM DC CIRCUIT CONDUCTORS.EXPOSED RACEWAYS.CABLE TRAYS&OTHER WIRING <br /> METHODS.COVERS OR ENCLOSURES OF PULL BOXES&JUNCTION BOXES.CONDUIT BODIES IN <br /> WHICH ANY OF THE AVAILABLE CONDUIT OPENINGS ARE UNUSED. <br /> LABELS OR MARKINGS SHALL BE VISIBLE AFTER INSTALLATION.REFLECTIVE WITH X'UPPERCASE, <br /> E - 3 <br /> 3 <br /> WHITE ON RED.EVERY SECTION OF THE WIRING SYSTEM SEPARATED BY ENCLOSURES,WALLS, <br /> PARTITIONS,CEILINGS,OR FLOORS.SPACING BETWEEN LABELS OR MARKINGS SHALL NOT BE <br /> MORE THAN 10' <br />