Laserfiche WebLink
12011 19th Avenue SE <br /> Everett,WA 98028 <br /> Project Number:2018-0363 <br /> 6.0 CONCLUSIONS AND RECOMMENDATIONS (continued) <br /> 6. Black mastic (Non-friable) There is approximately 125 square feet of <br /> Sample number: 2018-0363-3-12 asbestos-containing black mastic associated <br /> with the vinyl floor tiles located under multiple <br /> layers of flooring in the kitchen (upper level) <br /> of the fire station. The substrate is wood. <br /> f ' 3•tt <br /> 7. Tan vinyl floor tile (Non-friable) There is approximately 520 square feet of <br /> Sample number: 2018-0363-3-21 & 3-23 asbestos-containing tan vinyl floor tiles <br /> r located in the furnace room, work shop, and <br /> • office 3 (main floor) of the building. The <br /> associated brown mastic is however not <br /> asbestos containing. The substrate is <br /> NYL ,, concrete. <br /> 8. Gray caulking (Non-friable) There is approximately 60 linear feet of <br /> Sample numbers: 2018-0363-3-29 asbestos containing exterior gray caulking <br /> • associated with 6 aluminum windows of the <br /> fire house. <br /> ,•:.::\ • <br /> NVL1 <br /> 148888646227 ,;. y, <br /> uuu r .j Z`i . 1 . <br /> a <br /> t <br /> I I 1..,'''x. <br /> _ ,r <br /> Contractors should be aware that concealed suspect asbestos-containing building materials may be <br /> uncovered during the course of demolition or renovation work. Contractors should have contingency <br /> plans that include stopping work, evacuation of the immediate area and sampling by a certified AHERA <br /> Building Inspector whenever these materials are found. Concealed suspect materials may include, but <br /> are not limited to: non-fiberglass pipe or roof drain insulation; spray-applied coatings; cement board; <br /> asphalt or paper vapor barriers; floorings and adhesives. <br /> NVL Laboratories, Inc <br /> 4708 Aurora Ave N <br /> Seattle,WA 98199 <br /> Phone(206)547-0100•Fax(206)634-1936 13 <br />