Laserfiche WebLink
LOUVER SCHEDULE AIR If�LET �C QUTLET S�HEDULE <br /> BASIS OF DESIGN �� <br /> NOMINAL SIZE MAX P.D. TAG PURPOSE �ypE NECK SIZE CFM FINISH NC BORDER TYPE REMARKS <br /> TAG PURPOSE INSTALLATIQN TYPE ��N� MINIMUM FREE AREA CFM {�� Wc� MANUFACTURER AND MODEL REMARKS (I�I.) MFR Mt7qEL ' <br /> LV-4 HYDRAULIC PUMP AIR EXHAUST WALL 24x12 55� 680 0.15 RUSKIN ELF6375-DXH 1, 2, 3 sc� ro SUPPLY GRILLE 96x48 2�,00a ALUMINUM BLADES s� srEE� TITUS �32-Rs <br /> LV-5 HYDRAULIC PUMP AIR INTAKE WALL 20x20 55� 680 0.15 RUSKIN ELF6375--DXH 1, 2, 3 2 <br /> LV-6, 7 CONTROL ROOM AIR INTAKE / EXHAUST WALL 14x14 55� 4�0 0.15 RUSKIN ELF6375-DXH 1, 2, 3 RG1 JOINED W/ ALUMINUM ARRAY 6 GRILLES IN WALL 70 EQUAL 132 INCHES WIDE 6Y 8� , <br /> LV-8,9 HYDRAULIC PUMP ROOM MAKEUP AIR WALL 48x90 55% 11,000 - Tgp 1,4 <br /> 70 6 RETURN GRILLE 44x44 7,833 WHITE 2$ MULLIONS TITUS 355-ZFL INCHE5 HIGH <br /> LV-10,11 HYDRAULIC PUMP ROOM EXHAUST AIR WALL 48x96 55� 11,000 - (Tgp� 1,4 <br /> NOTES: 1 . COLOR TO BE SELECTED �Y OWNER. EG1 EXNAU57 GRILLE 12x12 500 WHITE 18 �IALL MOUNTED TITUS 350-RL <br /> 2. PROVIDE WITH FLANGED FRAME AND BIRD SCREEN. - <br /> 3. ALUMINUM LOUVER SD-1 DRUM LOUVER DIFFUSER 70x15 5,000 WHI7E 3� ALUMINUM TI7US DL FPMQ ERMINAL V�ELOCITY�AM O9 DEFLE�IONO FPM, 127'-0" � 50 <br /> 4. ACTUAL SIZE, CFM, MAX P.D., MANUFACTURER AND MODEL WILL BE SELECTED BY 80EING. � <br /> SD-2 SUPPLY AIR DIF�USER 10"� 5EE PLAN WNITE 32 ALUMINUM TtTUS TDC T <br /> S P LIT C 0 N D E N S I N G U N I T S C H E D U L E (V R F) RG-7 REfURN AIR GRILLE 22x22 1,270 WHITE 32 ALUMINUM TITUS 50F ' <br /> NOMINAL COOLING CAPACITY HEATING CAPACI7Y ELECTRICAL SHIPPED <br /> UNIT N0. LOCATION SERVICE EER/IEER BASIS OF DESIGN REMARKS RG-8 RETURN AIR GRILLE 14x14 400 WHITE 32 ALUMINUM TITUS 50F <br /> TON (BTU/HR) (BTU/Hn) VOL7S PH MCA MOCP WEIGHT (LBS) <br /> CU-A OUTDOOR CONTROL ROOM 12 12.5 / 21.2 144000 160000 460 3 21 35 706 MITSUBISHI PUHY-P144YLMU 1,2 , <br /> ; �: <br /> NOTES: 1. MOUNT ON 4° CONCREfE PAD MINIMUM 6° WIDER IN EACH DIREC710N THAN CONDENSING UNIT. C a I V D E I V�I I V G U N(T ��H E D U LE <br /> 2. DISCONNECT BY E�EC CONTRACTOR. <br /> � UNIT N0. AREA SERVED PAIRED MAKE MODEL UNIT SIZE SYSTEM LIQUID SUCTION ELECTRICAL SOUND WEIGHT REMARKS <br /> UNIT (TONS) SGOP (IN.) (IN.) VOLTS PH MCA MOCP dB(A) (LBS.) <br /> CU-1 5YSTEMS ROOM FCU-1 LIEBERT PFHZ37AL 3 2.59 1/2 7/� 208 1 22.3 35 57 351 1,2 ". <br /> NOTES: <br /> SPLIT FA�I CO L UNIT SCHEDULE ,. UNIT TO BE MOUNTED (�UTSIDE ON CONCREfE SLAB <br /> UNIT AREA MIN OSA FAN ELECTRICAL SHIPPED OUTDOOR 2. REFRIGERANT R-407C, CHARGED TO 426 OZ <br /> FILTER BA51S OF DESIGN REMARKS <br /> N0. SERVED (�F�� CFM ESP VOLTS PH MCA MOCP WEIGHT (LBS} UNIT N0. ,. <br /> FCU-A1 CONTROL ROOM 200 2150 0.8 208 1 7.7 15 MERV 13 214 MITSUBISHI PEFY--P72NMHSU CU-A 1, 2, 3 - <br /> FCU-A2 CONTROL ROOM 200 2150 0.� 208 1 7.7 15 MERV 13 214 MITSUBISHI PEFY-P72NMNSU CU-A 1, 2, � FAN C01 L U N IT SC H ED U LE <br /> NOTES: 1. INCLUDE MANUFACTURER DRAIN PU�iP MODEL PAC-KE05DM-F AND CONDENSATE OVERFLOW S�YITCH. COOLING COIL TOTAL FAN CFM ELECTRICAI � <br /> 2. INCLUDE MANUFAC7URER FILTER 60X WITH 4" MERV 13 FILTER MODEL FBH4-4, UNIT N0. AREA SERVED MAKE MODEL nP� (BTU�H) (RANGE) VOLTS PHASE ��g,� REMARKS <br /> 3. PROVIDE 24" LON� FULL SIZE PLENUM ON SUPPLY SIDE OF FAN COIL. FCU-1 SYSTEMS ROOM LIEBERT MMD36E SPLIT SYSTEM 33,800 1250 208 1 225 1,2,3 <br /> 4. PROVIDE BACNET INTERFACE FOR SITE HONEYWELL DDC SYSTEM. NOTES: <br /> 1. ELECTRICAL DISCONNECT BY ELECTRICAL CONTRACTOR. <br /> ENERGY RECOVERY VENTILATOR SCHEDULE 2. PROVIDE WITH WALL MOUNTED THERMOSTAT. w <br /> 3. ECONOMIZER EXCEPTIQN: COOLING UNITS AND SPLIT SYSTEMS WITH A TOTAL COOLING CAPACITY RATED IN ACCORDANCE WITH SECTION C403.2.3 OF LESS THAN 33,000 BTU/H <br /> SUPPLY FAN EXHAUST FAN SUMMER SUPPLY WINTER SUPPLY COOLING/HEATING ENERGY ELECTRICAL <br /> UNIT N0. LOCATION MAKE & MODEL FILTER QPER Wf. (LBS.) REMARKS <br /> CFM ESP HP BHP CFM ESP HP BHP * DB * DB EFFICIENCY VOLTS PH HZ FLA <br /> ERV-1 CONTROL ROOM ALDES E1100-FI 400 0.5 (2� q.4 OJ7 400 0.5 (2) 0,5 OJ7 77.4 F 64.7 F 59.3% / 58.5% 120 1 60 10.5 MERV 8 230 1 J <br /> ELECTRIC UNIT HEATEF� SCHEDU�E <br /> * WORST CASE DESIGN SUMMER AMBIENT TEMPERATURE 85F / 69F (DB/WB) AND WIN7ER 23F'. MARK LOCATION MAKE MODEL ARRANGEMENT KW /VOLT/ PH �AN WGT. REMARKS J <br /> NOTES: CFM VOL7S/PH <br /> 1. UNIT SHALL BE PROVIDED WITH A BASIC PROGRAMMABLE CONTROLLFR MOUNTED ON SPACE WALL. U - T SF Z - H L .5 4 5 80 3 1 <br /> UH-2 HYDRAULIC PUMP ROOM REZNOR EGEB-7 HORIZONTAL 7.5 / 480 / 3 625 480/3 37 1, 2, 3 <br /> NOTES: <br /> � 1. PROVIDE F'AN GUARq, WALL BRACKETS <br /> 2. NEATER CONTROLLED BY EMCS _ <br /> 3. BOTTOM OF UNIT SHALL BE AT LEAST 8 FOOT ABOVE FINISH FLOOR <br /> B � <br /> � <br /> .:� <br /> � I ,. <br /> NGl '� E � � S <br /> � � � � 1601 Fifth Avenus,Suite 900�Seattle,WA 98101 ,� �:; <br /> ph 206.623.071 T�fa7c 20$.824.3775 `c <br /> coffman.c�m �. <br /> LASTING creativity�results�relatioiships � _ <br /> e <br /> K <br /> C <br /> SYM REVI510N BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REYISION SYMBOL DA7E � <br /> �L .S'o ACCEP7A�ILITY G.ROUTH 05.26.15 <br /> - EDC STATIC TEST FACILITY W3099715 CEI MS 10.02.15 ,�� skl�� THIS DESIGN AND/OR CHECKED MEC�ANI�AL ��UIP�ENT �CH�DULE� W4440664 03.10.17 � <br /> � SPECIFICATION 15 APPROVED M.SOTURA 05.26.15 �H�� � <br /> A EDC STATIC TEST FACILITY - AS-BUILTS W3099715 CEI MS 09.01.16 � � , o�' TITLE EDC STATIC TEST FACILITY - PHASE 2 � <br /> � �, APPROVED BY DEPT. DATE COFFMAN 05.26.15 zx <br /> B EDC STATIC TEST FACILITY - PHASE 2 W4440664 CEI MS 03.10.17 cr�Eca�Eo � <br /> �E�86�� � APPROVED �I� �� ����� � J�B "�� W3099715 COMP N0. � * <br /> �'SSx �yCs�S' APPROVED DWG N0. <br /> �'�L , MECHANICAL MASTER EVERET�, WA 45--012-M2B � <br /> ,.{;. <br />