Laserfiche WebLink
�EGEND SYMBO �S ABBREUTATIONS GENERAL NOTES <br /> SECTION LETTER ROOF/ACCESS HATCH � <br /> OR DETAIL NUMBER DESIGNATION � & AND JT JOINT <br /> � AT 1. OBTAIN & POST REQUIRED CONSTRUCTION PERMITS FROM THE CITY OF EVERETT PRIOR <br /> BUILDING, WALL SECTIONS AB ANCHOR BOLT K KIP(S) TO COMMENCING CONSTRUCTION. <br /> �X # X � AND DETAIL REFERENCES ACP ACOUSTICAL CEILING PANEL KO KNOCK OUT <br /> � � TOILET 2. VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE BOEING PROJECT CONSTRUCTION ' <br /> SHEET NUMBER WHERE DETAILED ACT ACOUSTICAL CEILING TILE L LENGTH MANAGER SHOULD CONDITIONS DIFFER FROM DESIGN DOCUMENTS. <br /> ADJ ADJACENT <br /> SHEET NUMBER REFERENCED FROM URINAL AFF ABOVE FINISHED FLOOR LEN ENGBOLT 3. THE SCOPE OF WORK INCLUDES ALL WORK WITHIN THE CURRENT REVISION CLOUD(S) <br /> �---�� � AGG AGGREGATE ON EACH SHEET. IF THERE IS NO CLOUD ON A SHEET THE ENTIRE SHEET IS IN <br /> � � LF LINEAL FEET THE SCOPE OF WORK. INFORMATION OR WORK (WHETHER CLOUDED OR NOT) <br /> i i REFERENCE TO DETAIL/ENLARGED PLAN AL ALUMINUM LL LIVE LOAD REFERRED TO FROM WITHIN A CLOUD IS INCLUDED IN THE SCOPE OF WORK (I.E. - <br /> � � ALT ALTERNATE <br /> #X � x # �\`---� LAVATORY ALUM ALUMINUM LWR LOWER A SECTION OR DETAIL SYMBOL THAT LIES WITHIN A CLOUD ON A PLAN VIEW SHEET IS <br /> O INCLUDED IN THE SCOPE EVEN WHEN THE ACTUAL SECTION OR DETAIL DRAWN ON M <br /> ANCH ANCHOR, ANCHORAGE MATL MATERIAL THE DETAIL SHEET IS NOT CLOUDED.) <br /> X DETAIL DESIGNATION APA AMERICAN PLYWOOD ASSOC. MAX MAXIMUM <br /> APPD APPROVED 4. KEEP ALL AREAS UNDER CONSTRUCTION CLEAR OF DEBRIS CAUSED BY THIS SCOPE OF <br /> � MOP SINK MB MACHINE BOLT WORK. STORE CONSTRUCTION MATERIALS AND EQUIPMENT IN AREA DESIGNATED BY THE <br /> XXXX SHEET NUMBER WHERE DETAILED APPROX APPROXIMATE MBR MEMBER `_ <br /> (IF SAME AS SHEET REFERENCED FROM) ASTM AMERICAN SOCIETY OF BOEING PROJECT CONSTRUCTION MANAGER. � >�''., <br /> TESTING MATERIALS MTL METAL <br /> MFR MANUFACTURE(R) 5. VERIFY DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AND ENSURE THAT THE <br /> �/ SECTION/DETAIL DESIGNATION pF DRINKING FOUNTAIN MIN MINIMUM JOINING OF THE WORK OF VARIOUS TRADES MEETS APPROPRIATELY. BRING , <br /> �� INTERIOR ELEVATION BTWN BETWEEN DISCREPANCIES ON THE DRAWINGS OR IN SPECIFICATIONS TO THE ATTENTION OF THE <br /> X BLDG BUILDING MISC MISCELLANEOUS BOEING PROJECT CONSTRUCTION MANAGER IMMEDIATELY UPON DISCOVERY. THE CONTRACTOR <br /> XXXXX XXXXX SHEET NUMBER WHERE DETAILED xxx xx x �WHERE SPACE IS LIMITED) B�K� BLOCKING MO MASONRY OPENING SHALL ADVISE BOEING, SUMMARIZE THE SITUATION AND PROVIDE RECOMMENDATIONS TO <br /> BOT BOTTOM MT MOUNT(ED) (ING) RESOLVING POTENTIAL CONFLICTS PRIOR TO SUBMITTING ANY REQUESTS FOR INFORMATION <br /> SHEET NUMBER REFERENCED FROM REVISION CLOUD WITH e o SANITARY NAPKIN/TAMPON DISPENSER MTL METAL (RFIs). <br /> REVISION LETTER ��BEAK�� � � C CHANNEL 6. CONFORM ALL WORK TO APPLICABLE CODES, REGULATIONS AND INDUSTRY STANDARDS. � <br /> CB CATCH BASIN N NORTH (COORDINATE) <br /> N NORTH ARROW CC CENTER TO CENTER NF NEAR FACE 7. COMPLY WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR CONSTRUCTION <br /> A CEM CEMENT NIC NOT IN CONTRACT AREA AND SECURITY REGULATIONS. ' :��::, <br /> PAPER TOWEL DISPENSER/DISPOSAL <br /> CF CUBIC FEET <br /> INDICATES LINE OF NEW RESINOUS CJ CONTROL JOINT NOM NOMN AL 8. PROVIDE, AS IF DRAWN IN FULL, REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED � <br /> - FLOORING WORK THROUGHOUT SET <br /> CL CENTER LINE NTS NOT TO SCALE ON THE DRAWINGS. <br /> VCT CPT FLOOR MAT'L TRANSITION 8 DOUBLE ROLL TOILET PAPER DISPENSER CLG CEILING 9. DIMENSIONS ON DRAWINGS ARE TAKEN TO THE FACE OF MASONRY AND/OR CONCRETE � <br /> ELEVATION DATUM OA OVERALL <br /> CLR CLEAR(ANCE) WALLS, METAL STUDS, WOOD STUDS, AND TO THE CENTERLINE OF COLUMNS, UNLESS <br /> OR SPOT ELEVATION COL COLUMN a/C ON CENTER <br /> OTHERWISE NOTED. <br /> �'_�' CEILING HEIGHT A.F.F. ""''��"' FLOOR RECESS l��—�1 HANDICAP GRAB BAR, 1 1/2" O.D. COMP COMPRESS(ED) (ION) OD OUTSIDE DIAMETER <br /> CONC CONCRETE OF OUTSIDE FACE 10. DOOR OPENINGS ARE 6" FROM ADJACENT WALLS OR CENTERED IN ROOM WALL, UNLESS <br /> XXXXXX ROOM NAME OFCI OWNER FURNISHED CONTRACTOR DIMENSIONED OTHERWISE. <br /> �j CONN CONNECTION INSTALLED <br /> ��XXXX I I END WALL GUARD a TOILET SEAT COVER DISPENSER CONST CONSTRUCTION OPG OPENING 11. PLANS WHICH APPEAR AS "BACKGROUNDS" ON CIVIL, STRUCTURAL, PLUMBING, HVAC, <br /> ROOM NUMBER <br /> CONT CONTINUOUS, CONTINUE OPP OPPOSITE, OPPOSITE HAND ELECTRICAL DRAWINGS ETC., ARE FOR THE PURPOSE ONLY OF ILLUSTRATING GENERAL <br /> � CORNER GUARD coNTR CONTRACT(OR) PLAN CONFIGURATION. SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF <br /> XX DOOR NUMBER � CT CERAMIC TILE PAR PARALLEL THE WORK OTHER THAN THAT PERTAINING TO THE TITLE OF EACH SHEET. REFER TO <br /> EARTH, DIRT, UNDISTURBED CTSK COUNTERSUNK PCC PRECAST CONCRETE THE APPROPRIATE SHEET FOR EACH SPECIFIC PORTION OF THE WORK. <br /> X PARTITION/WALL TYPE CPT-1 FINISH DESIGNATION cY CUBIC YARD(S) PCF POUNDS PER CUBIC FOOT 12. COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, <br /> � ___ PERF PERFORATE(D) MECHANICAL AND ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC <br /> EARTH, DIRT, COMPACTED �, DIA DIAMETER PERIM PERIMETER TRADE REQUIREMENTS. COORDINATE ALL ROUGH-IN REQUIREMENTS FOR EQUIPMENT <br /> � DBL DOUBLE PL PLATE FURNISHED BY CONTRACTOR OR BY OTHERS FOR THIS PROJECT. <br /> GRID/GRID BUBBLE AND Q o 0 0,o�o os DEMOL DEMOLISH, DEMOLITION PLAM PLASTIC LAMINATE 13. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS TO THE BOEING PROJECT <br /> X °°°$°�.�°� STONE, GRAVEL, POROUS FILL <br /> CENTERLINE DEP DEPRESSED PLYWD PLYWOOD CONSTRUCTION MANAGER WHENEVER SUCH INSTRUCTIONS ARE REFERENCED IN THE <br /> DIA DIAMETER PNL PANEL CONSTRUCTION NOTES. „ <br /> --- --- --- -- CONSTRUCTION ABOVE OR BRICK, COMMON DIAG DIAGONAL PREST PRESTRESS(ED) <br /> BELOW, BEYOND OR BEHIND (HIDDEN) � DIM DIMENSION PRF PREFORMED 14. CONTRACTOR SHALL COORDINATE WITH THE BOEING PROJECT CONSTRUCTION <br /> DL DEAD LOAD PSF POUNDS PER SQUARE FOOT MANAGER FOR STAGING AREAS WHERE CONTRACTOR MAY STORE SALVAGED <br /> CONSTRUCTION "FLAG" NOTE FOR SPECIFIC CERAMIC TILE DN DOWN PSI POUNDS PER SQUARE INCH MATERIALS TO BE REUSED IN LATER PARTS OF THIS PROJECT AND WHERE MATERIALS TO <br /> � BE STAGED BY BOEING ARE TO BE LOCATED. <br /> CONSTRUCTION DIRECTIVE DS DOWNSPOUT PT POINT, PAINT <br /> ' DWG DRAWING PVC POLYVINYL CHLORIDE 15. SYMBOLS SHOWN ON MATERIALS LIST ARE NOT ALWAYS USED IN DRAWINGS. VERIFY <br /> GENERAL "BOAT" NOTE FOR ��.����+ .� ^ �•��� ' �� CONCRETE EXISTING MATERIAL AND SEE CONSTRUCTION NOTES FOR MATERIAL CALLOUTS. � <br /> � SPECIFIC OR EXISTING HISTORICAL E EAST (COORDINATE) R RADIUS (CURVATURE) ' <br /> INFORMATION. EA EACH R RISER 16. WHERE EXISTING WORK IS DAMAGED, CUT OR DEFACED AS A RESULT OF DEMOLITION OR <br /> �j��l��j����� INSUlATION: BATT, LOOSE FILL, BLANKET EB EXPANSION BOLT RB RESILIENT BASE PERFORMANCE OF NEW WORK, THE CONTRACTOR IS TO PATCH AND REPAIR THE EXISTING TO <br /> MATCH ADJOINING SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST <br /> OA WINDOW TYPE EF EACH FACE REF REFERENCE, REFER TO VISUAL BREAK LINES SUCH AS CORNERS, CEILING LINES, TOP OF BASE, CHANGE IN <br /> EJ EXPANSION JOINT REINF REINFORCE(D) (ING) MATERIAL OR SIMILAR. <br /> FEO- FIRE EXTINGUISHER INSULATION: RIGID EL ELEVATION REQ REQUIRE(D) (ING) � . <br /> ELEV ELEVATION REV REVISION(S), REVISED 17. ALL RECESSES LOCATED WITHIN FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO <br /> FEC� FIRE EXTINGUISHER & CABINET EQ EQUAL RH RIGHT HAND MAINTAIN REQUIRED FIRE RATING OF THE PARTITION. <br /> � ALUMINUM <br /> EW EACH WAY RO ROUGH OPENING 18. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE THE FINAL LOCATIONS OF <br /> a Q � SUPPLY AIR DIFFUSER EXIST EXISTING MECHANICAL AND ELECTRICAL COMPONENTS. SEE THE REFLECTED CEILING PLANS FOR <br /> BRASS, BRONZE, COPPER EXP EXPOSED S SOUTH (COORDINATE) LOCATIONS OF ITEMS IN THE CEILING; SEE DISCIPLINE SHEETS FOR ALL INFORMATION <br /> F �;`r `�'' � EXT EXTERIOR SECT SECTION ABOUT THE MECHANICAL AND ELECTRICAL COMPONENTS INDICATED ON ARCHITECTURAL <br /> � �m� �x RETURN AIR GRILLE <br /> - SF SQUARE FEET REFLECTED CEILING PLANS. <br /> FLOURESCENT LIGHT FIXTURE METAL, STEEL, IRON FAS FASTEN(ER) SHT SHEET 19. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE STRUCTURAL, MECHANICAL AND <br /> � (PENDANT MOUNTED) FF FINISHED CEILING SIM SIMILAR ELECTRICAL DRAWINGS FOR CUTTING AND PATCHING WORK WITHIN THE BUILDING, BEYOND <br /> PLASTER: SAND, CEMENT, GROUT FF IFACTORY FINISH SQ SQUARE THE LIMITS OF THE ARCHITECTURAL DRAWINGS. <br /> FLOURESCENT LIGHT FIXTURE � FF FINISHED FLOOR SST STAINLESS STEEL <br /> �� � ST STRUCTURAL TEE 20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN - <br /> (PENDANT MOUNTED) FGR FINISH GRADE ACCORDANCE WITH ALL SAFETY CODES, REGULATIONS AND BOEING REQUIREMENTS. <br /> �' - ' PLASTER: GYPSUM WALL BOARD <br /> FH FIRE HYDRANT STD STANDARD " <br /> � FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT FIN FINISH(ED) STL STEEL 21. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED <br /> LIGHT (NL) CIRCUIT FND FOUNDATION STR STRUCTURAL AND ASBESTOS CONTAINING MATERIAL WAS EITHER NOT DISCOVERED OR WILL BE REMOVED � � <br /> �_TZ��—I WOOD: FINISH FOC FACE OF CONCRETE SYM SYMMETRY,SYMMETRICAL PRIOR TO THE BEGINNING OF THE WORK FOR THIS PROJECT. A COPY OF THE REPORT OF ' <br /> FOF FACE OF FINISH SYS SYSTEM THE SURVEY WILL BE FURNISHED TO THE CONTRACTOR AT THE TIME OF BIDDING OR <br /> Q RECESSED OR PENDANT LIGHTING FIXTURE NEGOTIATIONS. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO <br /> i _.-------__ l WOOD: ROUGH CONTINUOUS FOIC FURNISHED BY OWNER/ T&g TOP AND BOTTOM THE WORK AREA. CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL ' <br /> � RECESSED OR PENDANT LIGHTING FIXTURE INSTALLED BY CONTRACTOR T&G TONGUE AND GROOVE IS DISCOVERED OR DAMAGED THAT IS REQUIRED TO BE REMOVED TO SUPPORT THE WORK OF <br /> � FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT FO FINISHED OPENING TEMP TEMPORARY THIS PROJECT. <br /> LIGHT (NL) CIRCUIT � � WOOD: INTERRUPTED BLOCKING FRO FOR REFERENCE ONLY THK THICK(NESS) THE OWNER WILL PROVIDE SEPARATE SURVEY LETTERS TITLED "GOOD FAITH INSPECITION FOR <br /> FT FOOT TOC TOP OF CURB ASBESTOS/ASBESTOS MAY BE IMPACTED OR ASBESTOS IMPACTED BY THIS SCOPE OF WORK" <br /> r—�—i WALL SCONCE 1 FTG FOOTING TOC TOP OF CONCRETE WITH THE PROJECT NUMBERS: . <br /> �� PLYWOOD: SMALL SCALE FUT FUTURE TOL TOLERANCE _ <br /> � a WALL SCONCE 2 FV FIELD VERIFY TOS TOP OF STEEL W5741115-8 - 40-023.M 1,H 1 <br /> W5741115-12 - 40-053.1.H7 � <br /> TS STRUCTURAL TUBE W5741115-15 - 40-030.M1,G-14 <br /> � EXIT SIGN (CEILING UNIT) �������� PLYWOOD: LARGE SCALE GA GAGE TYP TYPICAL b ` ' <br /> GALV GALVANIZED 22. NO CONTR ACTOR STORAGE OR S TAGING S PACE ON SITE, OTHER THAN THE RESTROOMS UNDER <br /> � EXIT SIGN (WALL MOUNT) GC GENERAL CONTRACTOR RENOVATION THEMSELVES. <br /> UBC UNIFORM BUILDING CODE <br /> GI GALVANIZED IRON UL UNDERWRITERS' LABEL <br /> � CEILING MOUNTED OCCUPANCY SENSOR WALL TYPE: CONCRETE MASONRY (CMU) GR GRADE UNO UNLESS NOTED OTHERWISE <br /> GT GROUT UPR UPPER <br /> �S SWITCH, OS INDICATES INTEGRAL OCCUPANCY SENSOR, D INDICATES GWB GYPSUM WALL BOARD <br /> INTEGRAL DIMMER (�����I WALL TYPE: STEEL STUD VB VAPOR BARRIER <br /> , HDNR HARDENER VC VINYL COMP. TILE <br /> 0 INTERCOM/SPEAKER HDWD HARDWOOD VERT VERTICAL � <br /> � i��i WALL TYPE: WOOD STUD HDWR HARDWARE <br /> �) 15A, 120V DUPLEX RECEPTACLE HG HIGH GRADE W WEST (COORDINATE) <br /> HM HOLLOW METAL W WIDE FLANGE <br /> �I HORZ HORIZONTAL W WIDTH, WIDE <br /> 20 20A, 120V, DUPLEX RECEPTACLE I I WALL TYPE: EXISTING HS HIGH STRENGTH WC WOOD <br /> � 15A, 120V, FOURPLEX RECEPTACLE HT HEIGHT WD WITH <br /> -------- W/ WITH <br /> W�741115 <br /> xx -------- WALL TYPE: REMOVAL IBC INTERNATIONAL BLDG. CODE W/a wiTHouT PHASE 1 RENOVATION PACKAGE <br /> � FIRE ALARM HORN/STROBE, xx INDICATES CANDELA RATING bllffCJIOdASlgtl WWF WELDED WIRE FABRIC IFC SUBMITTAL <br /> ID INSIDE DIAMETER <br /> � n n archiieciure � interiors ID INSIDE DIMENSION �7.�2.�$ <br /> DATA�TELEPHONE OUTLET „ � >� �s2o tourtn a�e \ � <br /> � � WALL TYPE: PARTITION (7 -0 HIGH) NOTE: REFER TO THE COLOR AND MATERIAL <br /> su�te aoo IF INSIDE FACE SCHEDULE FOR ADDITIONAL FINISH AND <br /> • FIRE SPRINKLER HEAD seatt�e,wa IN INCH ` <br /> 98101 DESIGNATIONS/ABBREVIATIONS <br /> ❑ WALL TYPE: GLASS 206 467 6306 INCL INCLUDED(D) (ING) <br /> FLOOR DRAIN buffalodesign.com <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DLR GROUP 12.31.08 SUBTIT�E �'�"'"" <br /> 3973 REGISTERED THIS DESIGN AND/OR CHECKED SYMBOLS, ABBREVIATIONS, GENERAL NOTES W5741115 � I o�.02.18 <br /> ORIG WORKPLACE ENVIRONMENT INVESTMENT W57411 15 BUFFALO 07.02.18 ARCHiTECT SPECrFICATION IS APPROVED � _ . �]sHEEr <br /> � __ E i rir�E WORKPLACE ENVIRONMENT INVESTMENT— � ' <br /> BOE,�� ` � � _APPROVED BY � DEPT. � DATE CHI �_ � �� �� <br /> GiC������i _ -r------ <br /> J�R,SE��AR��AR�SON _-�-----�----a BUILDING 40-023,40-030,40-037 �oe N0. COMP No. - <br /> � STATE OF W':A.SHINGTON APPROV�D - — W574� � �5 <br /> I I IAPPROVED ( �ARCHITECTURAL MASTER EVERETT, Wq�owc rvo. G2 <br /> I <br />