Laserfiche WebLink
� <br /> :� . <br /> �. <br /> O �3 VIA PC3 �.g,� o <br /> �5 VIA PC5 GENERAL NOTES: <br /> 0 <br /> l. WHEN STRANDED WIRE IS USED, ALL TERMINATIONS ARE MADE BY <br /> (2) 8' x 4' WHITE BOARDS w� A PRESSURE TERMINAL, BY TAILiNG OFF WITH SOLID CONDUCTORS <br /> 3 5 7 � OR OTHER APPROVED MEANS OF TERMINATION. <br /> MARKER TRAY (SHIP LOOSE) CPCPC ELECTRIC <br /> (NSTALLED ON SITE BY OTHERS PANEL 2. ALL CONDUCTORS ARE COPPER;TYPE THHN /THWN � <br /> ? O b T O b � � b 3. RATING OF STANDARD PANEL IS 22,000 A.I.C. . <br /> �. — � � - - - - - - - - - - -- — - - - - - - - - - - -- �1 <br /> ' � 4. WIRING METHOD IN METALLIC CONDUIT OR M.C. CABLE <br /> GFCI <br /> I �2,4 5. HVAC DISCONNECTS SHALL BE LABELED WITH AN IDENTIFICATION <br /> I PLATE SHOWING CIRCUIT NUMBER AND EQUIPMENT SERVED. <br /> � WAC 296-468-1 10 022 <br /> � ONE-LINE-DIAGRAM <br /> � 6. EXTERIOR WEATHER PROOF GFCI SHALL HAVE A"HEAVY DUTY" 100 AMP FEEDER PANEL <br /> � _ � � _ _ _ _ _ _ _ _ _ _ � � _ _ _ _ _ _ _ _ _ � � � _ � � WEATHERPROOF"INUSE"COVER. 2014NEC406.9(B)(1) MAIN BREAKER <br /> C � I 120/240 1� t <br /> j Ol O � O � 7. CONTROLLED RECEPTACLES SHALL SE LABELED PER 2014 NEC <br /> b b b I � PP 406.3(E) WITH THE TEXT"CONTROLLED"AND TNIS SYMBOL � 100 AMP <br /> r <br /> O nPP16 POWER 8• THIS PLAN IS NOT AN"AS-BUILT'CIRCUITS MAY BE RUN DIFFERENT <br /> � PACK TO SIGNAL THAN SHOWN BASED ON OBSTACLES ENCOUNTERED. STUB F OR BY1 BLAZERC STUB THRU <br /> I THERMOSTAT FUTURE (2) #2 Cu THHN <br /> I OCCUPIED PERIOD GROUNDING <br /> (1) #4 Cu THHN <br /> � AND (1) #6 Cu <br /> n 'J (WIRE �N SITE BY OTHERS) <br /> j � 51-11C WRC 2015 WSEC CHAPTER 4 NOTES: BON�iNc <br /> a <br /> -- - - - - - - - - - - - � � - - - - - - - - - - - -- ---- - -- 4 <br /> S 1, ALL LIGHTING SHALL CONFORM TO SECTION C405 <br /> 1 � <br /> } O a C G � 2. BASE CLASSROOM LIGHTING POWER DENSITY (C405.4.2.1� PANEL SCHEDULE <br /> I 833 SQ. FT.x 1 WATT PER SQUARE FOOT=833 WATfS ALLOWED <br /> NOTE: ALL CONDUCTORS COPPER. 100 AMP 1� 22,000 AIC <br /> � ADDITIONAL REDUCTION IN LIGHTING POWER DENSITY (C406.3.1) ° <br /> � 833 WATTS ALLOWED (BASE) x.75= 625 WATTS ALLOWED C� DESCRIPTION TRIP WIRE VOLT 1OO VOLT WIRE TRIP pESCRIPTION �� <br /> NO. AMPS SIZE AMPS A B AMPS SIZE AMPS NO. <br /> 1 LIGHTS ZO 12 552 �� �\ 7052 4 80 HVAC 2 <br /> I TOTAL WATTS ALLOWED = 625 i-� �� <br /> �,`n TOTAL WATTS INSTAILED=477 WATTS 3 RECEPTACIES 20 t2 1260 �� �\ 7052 / / / 4 <br /> o v %OF ALLOWED INSTALLED - 76%a 5 RECEPTACLES 20 12 1080 — – – – SPACE 6 <br /> 7 RECEPTACLES 20 12 900 �� �~ — — — SPACE 8 <br /> OC 3. 100%OF LIGHTING FIXTURES HAVE EMBEDDED OCCUPANCY AND 9 s�acE - - - �� �� - sPacE 10 <br /> DAYLIGHT SENSORS FOR INCREASED ENERGY SAVINGS, AND ARE 11 sPacE - - - �� �� - - - sPacE 12 <br /> INDIVIDUALLY ADDRESSABLE. (C406.4) �3 sPacE - - - �� �� – – – SPACE 14 <br /> 15 SPACE — — — �� �~ — — — � <br /> — SPACE 16 <br /> 4. 100%OF LIGHTING IS SET FOR CONTINUOUS DIMMING AND IS �� SPACE – – – r� �� – – – SPACE �8 <br /> ADJUSTABLE BY OCCUPANTS, FOR OCCUPANT COMFORT, VIA 19 SPACE - - - �� �� - - - sPacE 20 <br /> T R I A L P LA N wALL PODS. (C406.4) _ • <br /> ELEC C <br /> S. 50% OF RECEPTAC�ES ARE CONTROLLED BY LOCAL OCCUPANCY E L E C T R 1 C A L S Y M B O L S <br /> 1/4" = 1'-0" ARS 9/25/2017 <br /> SENSORS (C405.10) <br /> SYMBOL QESCRIPTION TO TOP REMARKS <br /> 6. THERMOSTAT OCCUPIED PERIOD WILL BE DETERMINED BY THE xx nLIGHT DIMMING CONTROL DIMMING CONTROL. LOWER CASE <br /> nLIGHT OCCUPANCY SENSORS INTEGRAL TO THE LIGHTING '� SWITCH CAT5E CONNECTED 48 �ETTERS DESIGNATE ZONING <br /> FIXTURES. <br /> H.V.A.C. (MOTOR, COMPRESSOR, HEATER SIZES) PC PLIUG LOADZCONTROL RELAY CEI�NG FIXTURELOCCUPANCY SENSORSED <br /> OPERATION VOLTAGE 197 MIN. 253 MAX. nLIGHT nPP16 THERMOSTAT ABOVE CONTROLLED BY nLIGHT ENABLED <br /> COMPRESSOR 11.8 RLA 83 LRA ELECTRICAL PLAN REVIEW P� CONTROL RELAY CEILING FfXTURE OCCUPANCY SENSORS <br /> OUTDOOR FAN 2.5 FLA 1/5 H.P. LOAD CALCULATIONS <br /> TR DUPLEX RECEPTRC�E 180 VA EACH <br /> INDOOR BLOWER FAN 2.8 FLA 1�3 H.P. � HALF CONTRO�LED HALF NOT 20 TAMPER RESISTANT � <br /> HEAT STRIP 10 KVA rR QUADPLEX RECEPTACLE 180 VA EACH <br /> MINIMUM CIRCU�T AMPS '79 qMpg VOLTAGE: �20/24o PHASE: �� � HALF CONTROLLED HALF HOT 20 TAMPER RESISTANT <br /> MAXiMUM OVERCURRENT PROTECTION SO AMPS NOTE: ALL DEVICES & FACE CONNECTED LOAD CALC. LOAD SINGLE RECESSED CLOCK <br /> a NANGER RECEPTACLE 84" 180 VA EACH <br /> OVERCURRENT PROTECTION- DUAL ELEMENT TIME DELAY FUSE PLATES TO BE IVORY � LIGHTING <br /> OR HACR CIRCUIT BREAKER <br /> EXTERIOR 75 VA x 125 % = 94 VA �c ci WEATHER RESISTANT GFCI <br /> RECEPTACLE 20" 180 VA EACH <br /> QTY. SIZE DESCRIPTION INTERIOR 477 VA x 125 % = 596 VA , PHONE / DATA BOX 20" 4" SQ BOX SINGLE GANG MR WITH <br /> 3/4" CONDUIT UP AND DOWN <br /> ELECTRICAL PANEL 1 100 120/240V - SINGLE PHASE - STUB THRU - METALLIC RACEWAY SYSTEM RECEPTACLES � FIRE ALARM PU�� STATION 48" <br /> THF2U 10,000 3240 VA x 100 % = 3240 VA 4" SQUARE BOX w/ SINGI.E GANG MUD <br /> 9 2 x 4 LED VOLUMETRIC TROFFER- nLIGHT ENABLEQ- 6000 LUMEN- 53 WATTS- 4000K FIRE ALARM tNTERIOR RING - 3/4" RACEWAY STUB UP ONLY <br /> WITH EMBEDDED OCCUPANCY AND DAYLIGHT SENSORS COMMUNICATING ON CAT5E � HORN / STROBE 84 PAINT BOX, MUDRING AND RACEWAY ' <br /> LIGHTING LOCAL NETWORK LITHQNIA - B�T460LADPEZ1LP840N100NES7ADCX OVER10,000 0 vA x 50 % = 0 VA "RED" IN COLOR <br /> MOTORS, COMPR. FIRE ALARM EXTERIOR <br /> � HORN / STROBE 84 <br /> 1 72 WATT LED WALL PACK w/ INTEGRAL PHOTOCELL ECONOLIGHT E-WP11L07CZ / E-ACP1 TOTAL 4104 vA x 100 % = 4104 vA <br /> T THERMOSTAT 48" 4" SQ BOX SINGLE GANG MR WITH <br /> HVAC 1 3 TON 10 KW BARD WALL HUNG HEAT PUMP w/ INTEGRAL ERV- 11 EER RATED LARGEST (2832) VA x 25 % = 708 VA O 1/2" CONDUIT STUB UP <br /> w/ MICROPROCESSOR— 7 DAY PROGRAMMABLE AUTOMATIC SETBACK— HEATING 10000 VA x 100 % = 10000 VA � LED WALL PACK 84" 75 VA EACH <br /> THERMOSTAT 1 BARD 8403-060 DEADBAND CONTROL — OCCUPANCY INTEGRATEQ INTO nUGHT SYSTEM <br /> 1 BARD CMC-29 FREEZE STAT O nLIGHT ENABLED LED TROFFER CEILING 53 VA EACH <br /> TOTAL KVA 17.90 TOTAL KVA 18.74 � W/ INTEGRAL SENSORS <br /> CO2 SENSOR 1 BARD 8403-Q67 - DEMAND CONTROL VENTILATION CONNECTED CALCULATED T <br /> LOAD AMPS 7q-.57 LOAD AMPS 78.09 � ELECTRICAL PANEL 72" <br /> 7-17-17 ELECTRICAL ENGINEERING ARS COPYRIGHT 2017, BLAZER INDUSTRIES, INC. � MODULAR Approved for Const: Job No: 19031 <br /> 9-25-17 REDUCED PANEL SIZE TO 100 AMP � ARS THIS MATERIAL IS THE EXCLUSIVE PROPERTY C/assroom for.� <br /> OF BLAZER INDUSTRIES, INC.AND SHALL ■■ File Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED �� INDUSTRIES,iNC. 2$ X 32 KC DA - Eve rett S■D■ Drawn By: LDG � <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE �� www,biazerind.com <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� P.O.BOX 489 ■ Aumsvi��e,OR 97325-0489 �NA. GOLD Pacific Mobile 17 BLMP-04 A9 W/4 Issue Date: 9 25-17 <br /> �: <br />