<br /> � 1. VISIT AND EXAMINE THE SITE PRIOR TO CONSTRUCTION TO ASCERTAIN THE CONDITIONS
<br /> �; � � AND LIMITS OF DEMOLITION AND CONSTRUCTION.
<br /> _ _ , +96" � � � _.�p,F,j, ,S' �,,y
<br /> i � 2. DISPOSE OF ALL REMOVED EQUIPMENT UNLESS DIRECTED TO DO OTHERWISE BY THESE
<br /> I DOCUMENEfS OR THE OWNER. �G�� • �
<br /> � ' 3. DISCONNECT, REMOVE OR RELOCATE EXISTING ELECTRICAL INSTALLATION AS INDICATED. � C�
<br /> � THIS INCLUDES, BUT NOT LIMITED TO PANELS, LIGHT FIXTURES, WIRING DEVICES, ETC.
<br /> I I COORDINATE WITH MECHANICAL PRIOR TO DEMOLITION OF ANY EQUIPMENT. .
<br /> 4. SEE MECHANICAL DRAWINGS FOR HEATERS, EXHAUST FANS, ETC. WHICH MUST BE 12/ �J2017
<br /> +42"�—�— DISCONNECTED BY DIVISION 26 FOR REMOVAL OR ABANDONMENT BY DIVISION 23. 273 �
<br /> 5. REMOVE ALL CONDUIT, WIRE, BOXES AND FASTENING DEVICES A5 REQUIRED TO AVO�D �¢3
<br /> '� ANY INTERFERENCE WITH NEW INSTALLATION. ABANDONED CONDUIT SHALL BE CAPPED AT �'
<br /> � �REF BOTH ENDS.
<br /> � 6. SYSTEMS WHICH REQUIRE INTERRUPTION OF SERVICE SHALL BE COORDINATED WITH
<br /> OWNER.
<br /> (J1 +90" � �—
<br /> � 7. REMOVE ALL POWER SYSTEMS AS INDICATED OR REQUIRED TO CLEAR AREA FOR NEW
<br /> PANEL L2SE INSTALLATION.
<br /> \ 8. RECONNECT ANY EQUIPMENT BEING DISTURBED BY THESE RENOVATIONS YET REQUIRED
<br /> � � ( I � � FOR CONTINUED SERVICE.
<br /> / \ \ 9. WHERE WORK (WALL REMOVAL, NEW OR RELOCATED WALL OPENINGS, ETC.) RESULTS IN
<br /> I I I I I \ 3; `� THE REMOVAL OF LIGHT FIXTURES, DISCONNECT OR RECONNECT AS REQUIRED ALL
<br /> / \ ACTIVE DEVICES REMAINING ON THE CIRCUIT SYSTEM.
<br /> 10. EXISTING ELECTRICAL DEVICES ARE BASED ON RECORD DRAWINGS. NOT ALL DEVICES
<br /> ��1� I � �(�� � ( C � TO BE REMQVED MAY BE SHOWN. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. ALL W
<br /> �' � � � 'i-� RECEPTACLES ON DEMO WALLS TO BE DEM�LISHED. �
<br /> I � / 11. CIRCUIT NUMBERS SHOWN REFER TO PANELS 'L2SE'. W
<br /> � �J1 +60 � / 12. FOR LOAD REDUCTIONS, REFER TO (BEFORE) PANEL SCHEDULES. �I
<br /> J
<br /> — � � — � FLAG NOTES Q z
<br /> / / V �
<br /> / / � � FIRE ALARM CONTROL PANEL TO BE RELOCATED. PROVIDE LABOR AND MATERIALS � � O
<br /> T fl AS REQUIRED TO INTERCEPT EXISTING CIRCUIT L2XA-7 IN CEILING. MAINTAIN I— N
<br /> I I I � CIRCUIT IN CEILING FOR EXTENSION AND RECONNECTION IN NEW LOCATION. SEE � � � �
<br /> 1 �— _ E2.1 FOR ADDITIONAL INFORMATION. � W � .
<br /> Q
<br /> �, , ; � � � �
<br /> � � � ,�,,_ o �
<br /> I +48" I � � oo W
<br /> I I� r� ►- O � � �
<br /> I „� � V � w
<br /> ,„ , +86 J
<br /> W ( � ' ~ �
<br /> � _ I ,
<br /> -_ __� P i�"� � � � � �
<br /> ��7_
<br /> �+48" � �� � � �
<br /> � \ .
<br /> +42" L14-30R W
<br /> \ � I �-� >
<br /> II � � � =�� �
<br /> <J�J �
<br /> � � ��� �� W
<br /> �
<br /> ��� ��11� ( � 1� �J1+86" � �..HWT
<br /> 1
<br /> � �
<br /> �
<br /> �
<br /> , ; ; .
<br /> � ,
<br /> ,
<br /> � . _ � � �
<br /> _ __ _ _ _
<br /> _ _ �
<br /> _ __ ___ ____ _ ______.
<br /> _ _..__ ._.._ ____.._.. ._.._____ _.__._ _._____ __-.----___ � � � ; ',
<br /> _� � ' � � � -
<br /> '�,
<br /> ; , i _
<br /> , ,_._�-.__-� _
<br /> � � � i �
<br /> , ,
<br /> �
<br /> NORTH � j
<br /> 1 ST FLOOR DEMOLITION POWER PLAN !
<br /> ; ;
<br /> SCALE: 3/8" = 1'-0" 1� ..; �
<br /> i •
<br /> c�i �
<br /> � �
<br /> O , i
<br /> .j o ,I
<br /> � � �
<br /> 'V �
<br /> �
<br /> _ ._.
<br /> _ �
<br /> _
<br /> , � _ i _� � �
<br /> � � �
<br /> - --• � � �
<br /> , � Q �
<br /> y . �_ �.,: �
<br /> . , �., _ .;,_ ,���,,,�nk•;., ._ � . .
<br /> r � - --
<br /> �+
<br /> }\ If �� � � ' m �
<br /> I
<br /> � � ' , � �, � U
<br /> � � �
<br /> ` ' � (�
<br /> � : , i� � �k ' _ � U
<br /> �, �� .
<br /> �R ,;
<br /> �— �� Sheet No / Title:
<br /> - . � 0 ;
<br /> -- . PARTIAL 1 ST FLOOR
<br /> . , �; � ,
<br /> DEMOLITIC�N
<br /> 3
<br /> POWER PLAN