Laserfiche WebLink
• <br /> � � <br /> 1011 SW Klickitat Way, Suite 208 <br /> Seattle,WA 98134 <br /> P: 206.631.8442 � www.oaips.com <br /> �� `� <br /> �� ; � � <br /> `�.� I ENGINEERING <br /> _ _ <br /> � � Consulting Electrical Engineers . <br /> I-_______------._�------------------_--_ — — <br /> I � � 19515 North Creek Parkway, Suite 302 <br /> � � Bothell, Washington 98011 <br /> : ; �E M 0 L�-T-��N N�-T-ES Phone: 425-402-9400 Fax: 425-402-9402 <br /> �J1 � <br /> � 1. VISIT AND EXAMINE THE SITE PRIOR TO CONSTRUCTION TO ASCERTAIN THE CONDITIONS <br /> �; � � AND LIMITS OF DEMOLITION AND CONSTRUCTION. <br /> _ _ , +96" � � � _.�p,F,j, ,S' �,,y <br /> i � 2. DISPOSE OF ALL REMOVED EQUIPMENT UNLESS DIRECTED TO DO OTHERWISE BY THESE <br /> I DOCUMENEfS OR THE OWNER. �G�� • � <br /> � ' 3. DISCONNECT, REMOVE OR RELOCATE EXISTING ELECTRICAL INSTALLATION AS INDICATED. � C� <br /> � THIS INCLUDES, BUT NOT LIMITED TO PANELS, LIGHT FIXTURES, WIRING DEVICES, ETC. <br /> I I COORDINATE WITH MECHANICAL PRIOR TO DEMOLITION OF ANY EQUIPMENT. . <br /> 4. SEE MECHANICAL DRAWINGS FOR HEATERS, EXHAUST FANS, ETC. WHICH MUST BE 12/ �J2017 <br /> +42"�—�— DISCONNECTED BY DIVISION 26 FOR REMOVAL OR ABANDONMENT BY DIVISION 23. 273 � <br /> 5. REMOVE ALL CONDUIT, WIRE, BOXES AND FASTENING DEVICES A5 REQUIRED TO AVO�D �¢3 <br /> '� ANY INTERFERENCE WITH NEW INSTALLATION. ABANDONED CONDUIT SHALL BE CAPPED AT �' <br /> � �REF BOTH ENDS. <br /> � 6. SYSTEMS WHICH REQUIRE INTERRUPTION OF SERVICE SHALL BE COORDINATED WITH <br /> OWNER. <br /> (J1 +90" � �— <br /> � 7. REMOVE ALL POWER SYSTEMS AS INDICATED OR REQUIRED TO CLEAR AREA FOR NEW <br /> PANEL L2SE INSTALLATION. <br /> \ 8. RECONNECT ANY EQUIPMENT BEING DISTURBED BY THESE RENOVATIONS YET REQUIRED <br /> � � ( I � � FOR CONTINUED SERVICE. <br /> / \ \ 9. WHERE WORK (WALL REMOVAL, NEW OR RELOCATED WALL OPENINGS, ETC.) RESULTS IN <br /> I I I I I \ 3; `� THE REMOVAL OF LIGHT FIXTURES, DISCONNECT OR RECONNECT AS REQUIRED ALL <br /> / \ ACTIVE DEVICES REMAINING ON THE CIRCUIT SYSTEM. <br /> 10. EXISTING ELECTRICAL DEVICES ARE BASED ON RECORD DRAWINGS. NOT ALL DEVICES <br /> ��1� I � �(�� � ( C � TO BE REMQVED MAY BE SHOWN. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. ALL W <br /> �' � � � 'i-� RECEPTACLES ON DEMO WALLS TO BE DEM�LISHED. � <br /> I � / 11. CIRCUIT NUMBERS SHOWN REFER TO PANELS 'L2SE'. W <br /> � �J1 +60 � / 12. FOR LOAD REDUCTIONS, REFER TO (BEFORE) PANEL SCHEDULES. �I <br /> J <br /> — � � — � FLAG NOTES Q z <br /> / / V � <br /> / / � � FIRE ALARM CONTROL PANEL TO BE RELOCATED. PROVIDE LABOR AND MATERIALS � � O <br /> T fl AS REQUIRED TO INTERCEPT EXISTING CIRCUIT L2XA-7 IN CEILING. MAINTAIN I— N <br /> I I I � CIRCUIT IN CEILING FOR EXTENSION AND RECONNECTION IN NEW LOCATION. SEE � � � � <br /> 1 �— _ E2.1 FOR ADDITIONAL INFORMATION. � W � . <br /> Q <br /> �, , ; � � � � <br /> � � � ,�,,_ o � <br /> I +48" I � � oo W <br /> I I� r� ►- O � � � <br /> I „� � V � w <br /> ,„ , +86 J <br /> W ( � ' ~ � <br /> � _ I , <br /> -_ __� P i�"� � � � � � <br /> ��7_ <br /> �+48" � �� � � � <br /> � \ . <br /> +42" L14-30R W <br /> \ � I �-� > <br /> II � � � =�� � <br /> <J�J � <br /> � � ��� �� W <br /> � <br /> ��� ��11� ( � 1� �J1+86" � �..HWT <br /> 1 <br /> � � <br /> � <br /> � <br /> , ; ; . <br /> � , <br /> , <br /> � . _ � � � <br /> _ __ _ _ _ <br /> _ _ � <br /> _ __ ___ ____ _ ______. <br /> _ _..__ ._.._ ____.._.. ._.._____ _.__._ _._____ __-.----___ � � � ; ', <br /> _� � ' � � � - <br /> '�, <br /> ; , i _ <br /> , ,_._�-.__-� _ <br /> � � � i � <br /> , , <br /> � <br /> NORTH � j <br /> 1 ST FLOOR DEMOLITION POWER PLAN ! <br /> ; ; <br /> SCALE: 3/8" = 1'-0" 1� ..; � <br /> i • <br /> c�i � <br /> � � <br /> O , i <br /> .j o ,I <br /> � � � <br /> 'V � <br /> � <br /> _ ._. <br /> _ � <br /> _ <br /> , � _ i _� � � <br /> � � � <br /> - --• � � � <br /> , � Q � <br /> y . �_ �.,: � <br /> . , �., _ .;,_ ,���,,,�nk•;., ._ � . . <br /> r � - -- <br /> �+ <br /> }\ If �� � � ' m � <br /> I <br /> � � ' , � �, � U <br /> � � � <br /> ` ' � (� <br /> � : , i� � �k ' _ � U <br /> �, �� . <br /> �R ,; <br /> �— �� Sheet No / Title: <br /> - . � 0 ; <br /> -- . PARTIAL 1 ST FLOOR <br /> . , �; � , <br /> DEMOLITIC�N <br /> 3 <br /> POWER PLAN <br /> . <br /> K EY P LA N Project#: 1705.08 <br /> NOT TO SCALE <br /> . ......_...»...... ....., <br />