My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 TOWER ST 2018 PARKS HALL Plans 2022-11-02
>
Address Records
>
TOWER ST
>
2000
>
PARKS HALL
>
Plans
>
2000 TOWER ST 2018 PARKS HALL Plans 2022-11-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2022 2:47:26 PM
Creation date
8/13/2019 9:13:02 AM
Metadata
Fields
Template:
Address Document
Street Name
TOWER ST
Street Number
2000
Tenant Name
PARKS HALL
Permit
B1801-025
Year
2018
Notes
RENOVATE SECURITY OFFICE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> � <br /> 1011 SW Klickitat Way, Suite 208 <br /> Seattle, WA 98134 <br /> P: 206.631.8442 � www.oaips.com <br /> , ` <br /> � E <br /> � _ , I ENGINEERiNG <br /> Consulting Electrical Engineers <br /> _ _, � � � <br /> � <br /> _�, ! <br /> � _ I �� � � 7 ; _ i 1951 Bothehl, Washngtona98011te 3 <br /> l— <br /> � I I � I DEMOLITION NOTES Phone: 425-402-9400 Fax: 425-402-9402 <br /> j � <br /> I � <br /> , ! II <br /> 1. VISIT AND EXAMINE THE SITE PRIOR TO CONSTRUCTION TO ASCERTAIN THE CONDITIONS <br /> � - - - - - - AND LIMITS OF DEMOLITION AND CONSTRUCTION. <br /> ;..�� I I <br /> r �I 2. DISPOSE OF ALL REMOVED EQUIPMENT UNLESS DIRECTED TO DO OTHERWISE BY THESE '��'�L S C�' <br /> — — .� — — � — — � — — —� I / � / I DOCUMENETS OR THE OWNER. ti� � <br /> � � � � /1 / 3. DISCONNECT, REMOVE OR RELOCATE EXISTING ELECTRICAL INSTALLATION AS INDICATED. � fr � <br /> I I I I y � � I THIS INCLUDES, BUT NOT LIMITED TO PANELS, LIGHT FIXTURES, WIRING DEVICES, ETC. �,_, <br /> I \\ I I \\ I I \\ I I \\ I �/— - - - - J COORDINATE WITH MECHANICAL PRIOR TO DEMOLITION OF ANY EQUIPMENT. �J' <br /> I � ( ( � I I I 4. SEE MECHANICAL DRAWINGS FOR HEATERS, EXHAUST FANS, ETC. WHICH MUST BE 'I2/ �2017 <br /> I \ I I \ I � �' <br /> I � I I � I I � I � � � DISCONNECTED BY DIVISION 26 FOR REMOVAL OR ABANDONMENT BY DIVISION 23. <br /> j 5. REMOVE ALL CONDUIT, WIRE, BOXES AND FASTENING DEVICES AS REQUIRED TO AVOID �� � <br /> I � I I � I I I I � I I � I � � ANY INTERFERENCE WITH NEW INSTALLATION. ABANDONED CONDUIT SHALL BE CAPPED AT <br /> I � I I � I I � I I � I ' ' BOTH ENDS. <br /> L - - � L - - � I I L - - � L - - � 6. SYSTEMS WHICH REQUIRE INTERRUPTION OF SERVICE SHALL BE COORDINATED WITH <br /> OWNER. <br /> - � �— 7. REMOVE ALL POWER SYSTEMS AS INDICATED OR REQUIRED TO CLEAR AREA FOR NEW <br /> -'_''_..' I <br /> PANEL L2SE INSTALLATION. <br /> \ , ; 8. RECONNECT ANY EQUIPMENT BEING DISTURBED BY THESE RENOVATIONS YET REQUIRED <br /> / I ( � \ ��-� FOR CONTINUED SERVICE. <br /> � � �%, <br /> / \ g. WHERE WORK (WALL REMOVAL, NEW OR RELOCATED WALL OPENINGS, ETC.) RESULTS IN <br /> � �- - - - - - � ACTIVEEDEVCES�REMAHNING ONRTHEDCIRCUITESYSOE RECONNECT AS REQUIRED ALL <br /> I I ( I I I � � 10. EXISTING ELECTRICAL DEVICES ARE BASED ON RECORD DRAWINGS. NOT ALL DEVICES <br /> / \ � , � � � W . <br /> � � I TO BE REMOVED MAY BE SHOWN. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. ALL <br /> S I i � I RECEPTACLES ON DEMO WALLS TO BE DEMOLISHED. � <br /> , � � � I�/— — — — — -� / 11. CIRCUIT NUMBERS SHOWN REFER TO PANELS 'L2SE'. W <br /> I —I--� � / 12. FOR LOAO REDUCTIONS, REFER TO (BEFORE) PANEL SCHEDULES. J � <br /> � � — � FLAG NOTES Q z <br /> — � cn p � <br /> / / � FIRE ALARM CONTROL PANEL TO BE RELOCATED. PROVIDE LABOR AND MATERIALS � U O <br /> / � AS REQUIRED TO INTERCEPT EXISTING CIRCUIT L2XA-7 IN CEILING. MAINTAIN � � � � <br /> � CIRCUIT IN CEILING FOR EXTENSION AND RECONNECTION IN NEW LOCATION. SEE <br /> — _ _ _ � E2.1 FOR ADDITIONAL INFORMATION. Z U W Q <br /> m � � __ � <br /> � I � I I � � - - � i 2� LOAD REDUCED BY 1359 V A O N P A N E L H 2 L A, C I R C U I T #2. _ � � �j <br /> ( I I � � � � \ � I \ I � 0 0 ~ <br /> � � � � � � I I - - I \� I - - - - - � � � p W <br /> I I I I \ I I � I � � I � I r � � � � � `V > <br /> I \� I IF32T8 �� I I I \ I ( � � � � / � V � W <br /> ( I I � � I I I � I � \ � � � - - � I � 4 F— U <br /> L - - � �-n� — � I \ i _ � � - - - <br /> W � ) � � ' = w � <br /> � _ <br /> � � i . � � <br /> � � � W <br /> I� � L - - � � > <br /> � I I W <br /> I I � 1-�MP I I <br /> � <br /> 4 _..p 60W MEDIUM BASE I <br /> LJ S L � (-�"P)Ls I I <br /> I <br /> � � <br /> � <br /> � � <br /> � <br /> �1 . <br /> _ <br /> II � � , <br /> _ ._._._ _ �_ ___.___--______ _ --_.________.__---_---__________—.____ .---�_ _ �_. __ _ __ _ -� � <br /> - , <br /> , <br /> ___.__�_ _��._ � � ; <br /> _. __�v___� , <br /> 'i , � <br /> NORTH i � <br /> 1 ST FLOOR DEMOLITION LIGHTING PLAN <br /> 2 \� <br /> � SCALE: 3/8" = 1'-0" I <br /> � I <br /> C <br /> O ' <br /> .j o � <br /> ��/ � �, I <br /> LL (,�j <br /> _ _.. ' � �.: �, � � <br /> ... <br /> � � N � � <br /> t, � O � <br /> � �_- ��.. _ �. � -- ---- � � <br /> �;___� tA . . <br /> _ N i >+ � <br /> {! -� �, m <br /> � � a� <br /> ` i _ ,i � i, � � <br /> r .� i <br /> a� <br /> ,` i € ; � � � � � � � � � � <br /> ��� t{ - �I CI� � � U <br /> �., G� <br /> � j Sheet No / Title: <br /> , . , <br /> a _. ��� PARTIAL 1 ST FLOOR <br /> _ � � <br /> - DEMOLITION <br /> _F . . <br /> _ , LIGHTING PLAN <br /> . <br /> K EY P LA N Project#: 1705.08 <br /> NOT TO SCALE <br /> • M���M��M������• •����� <br />
The URL can be used to link to this page
Your browser does not support the video tag.